Abstract
Abstract As information and communication technologies continuously develop and improve, they are increasingly incorporated into the fields of civil engineering, construction and infrastructure. Decision-making in construction projects is key to being competitive and guaranteeing the quality of structures. Integrated monitoring systems play an important role in concrete structures. Tracking humidity and temperature provides information on concrete hydration and hardening processes. This study focuses on creating a technically and economically viable data recording system. To this end, general purpose dual sensors have been incorporated (for temperature/humidity). With the aim of measuring these values in the interior of concrete, different options for encapsulating the sensors have been examined. An economical proposal of this kind consists of a wireless network that provides data in real time, and therefore facilitates decision-making for builders and project management. Obtaining reliable data from the concrete interior allows us to verify if the hardening process has evolved correctly. In the future, this type of verification test could replace the inspection currently mandated by regulations. The cost of the proposed system offers savings of 45.37% compared to existing controls.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: BIM and Construction Integration · Concrete Corrosion and Durability · Infrastructure Maintenance and Monitoring
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (38)
Show source-provided references
1. Concrete temperature, maturity and strength
2. AEN/CTN 140, Eurocode 2: Design of concrete structures – Part 1-1: General rules and rules for buildings, 2015.
3. Ministry of Public Works Spain, Code on Structural Concrete (Spanish abbreviation – EHE-08), 2008.
4. AEN/CTN 83, EN 12350-1 Testing fresh concrete – Part 1: Sampling, 2009.
5. AEN/CTN 83, EN 12350-2 Testing fresh concrete – Part 2: Slump-test, 2009.
6. AEN/CTN 83, EN 12390-1 Testing hardened concrete – Part 1: Shape, dimensions and other requirements for specimens and moulds, 2013.
7. AEN/CTN 83, EN 12390-2 Testing hardened concrete – Part 2: Making and curing specimens for strength tests. 2009.
8. AEN/CTN 83, EN 12390-3 Testing hardened concrete – Part 3: Compressive strength of test specimens, 2009.
9. AEN/CTN 83, EN 12390-4 Testing hardened concrete – Part 4: Compressive strength - Specification for testing machines, 2001.
10. Sensor systems for use in reinforced concrete structures10.1016/j.conbuildmat.2004.03.008 ↗
11. T-WiEYE: An early-age concrete strength development monitoring and miniaturized wireless impedance sensing system10.1016/j.proeng.2011.04.082 ↗
12. Development of an embedded wireless sensing system for the monitoring of concrete10.1177/1475921711430438 ↗
13. Ultrasonic guided wave active sensing for monitoring of split failures in reinforced concrete10.1177/1475921715591876 ↗
14. Design and mechanical characterization of fibre optic plate sensor for crack monitoring
15. Wireless Crack Detection in Concrete Elements Using Conductive Surface Sensors and Radio Frequency Identification Technology10.1061/(ASCE)MT.1943-5533.0000891 ↗
16. Development of an embeddable sensor to monitor the corrosion process of new and existing reinforced concrete structures10.1016/j.conbuildmat.2009.04.001 ↗
17. A wireless embedded passive sensor for monitoring the corrosion potential of reinforcing steel10.1088/0964-1726/22/7/075019 ↗
18. A RFID sensor for corrosion monitoring in concrete10.1109/JSEN.2015.2476997 ↗
19. Examples of reinforcement corrosion monitoring by embedded sensors in concrete structures10.1016/j.cemconcomp.2009.05.007 ↗
20. Corrosion assessment of reinforced concrete structures based on equivalent structural parameters using electro-mechanical impedance technique10.1177/1045389X13498317 ↗
21. Reinforcement corrosion assessment capability of surface bonded and embedded piezo sensors for reinforced concrete structures10.1177/1045389X14554133 ↗
22. Developments in monitoring techniques for durability assessment of cover-zone concrete
23. Design of a long-period fiber grating sensor for reinforcing bar corrosion in concrete10.1177/1045389X11430729 ↗
24. Detection and quantification of diameter reduction due to corrosion in reinforcing steel bars10.1177/1475921715578315 ↗
25. Editorial: Automated monitoring of concrete structures – research opportunities10.1680/macr.2011.63.2.79 ↗
26. The response of embedded strain sensors in concrete beams subjected to thermal loading10.1016/j.conbuildmat.2014.07.102 ↗
27. Using digital image correlation to evaluate fatigue behavior of strengthened reinforced concrete beams10.1016/j.engstruct.2015.10.017 ↗
28. Temperature and moisture monitoring in concrete structures using embedded nanotechnology/microelectromechanical systems (MEMS) sensors10.1016/j.conbuildmat.2006.05.047 ↗
29. Implementing RFIC and sensor technology to measure temperature and humidity inside concrete structures10.1016/j.conbuildmat.2011.06.066 ↗
30. Wireless sensor networks for temperature and humidity monitoring within concrete structures10.1016/j.conbuildmat.2012.11.087 ↗
31. High frequency and ultrahigh frequency radio frequency identification passive sensor10.1109/TIM.2013.2258763 ↗
32. Mass concrete structure damage identification research based on wireless sensor networks and agents10.1504/IJSNET.2015.069586 ↗
33. Concrete temperature monitoring using passive wireless surface acoustic wave sensor system10.1016/j.sna.2015.01.028 ↗
34. The experimental study on concrete permeability of wireless communication module embedded in reinforced concrete structures
35. Monitoring method for the chloride ion penetration in mortar by a thin-film sensor reacting to chloride ion10.1016/j.conbuildmat.2013.11.095 ↗
36. Use of fiber Bragg grating sensors for monitoring concrete structures with prestressed near-surface mounted carbon fiber-reinforced polymer strips10.1177/1045389X13489364 ↗
37. Optimum wireless powering of sensors embedded in concrete10.1109/TAP.2011.2173147 ↗
38. CYPE Ingenieros S.A., “CYPE Ingenieros S.A. Software for Architecture, Engineering and Construction. Spain, 2016”, 2016.