journal article·2026-06

Fatigue behaviour of direct and CAD/CAM indirect restorative materials bonded to a dentine analogue substrate

Yanning Chen, Hao Ding, Qianhui Li, Shujiang Chen, Xuedong Bai, Edmond Ho Nang Pow, James Kit Hon Tsoi

Publisher page

Abstract

Objectives This study aimed to investigate the fatigue behaviour of direct and CAD/CAM indirect restorative materials cemented to a dentine analogue substrate. Materials & methods Two resin-based direct restorative materials (G-ænial Universal Injectable, GU; Filtek Supreme Flowable Restorative, FS), and two CAD/CAM indirect restorative materials (IPS e.max CAD, EM; Tetric CAD, TE), were tested. Flexural properties (flexural strength and flexural modulus) and energy dissipation parameters (modulus of toughness, elastic recovery, and their difference) were determined via the three-point bending (3PB) test (n = 10). After the monotonic pilot trial, the wet cyclic fatigue test was performed following the staircase approach (initial load: approx. 40% of the monotonic load; step size: approx. 5% of the monotonic load; 500,000 cycles per specimen; 20 Hz; n = 15). Mean fatigue failure load (FFL), standard deviation (SD), and 95% confidence interval (CI) were calculated using the Dixon and Mood method. FFLs were also evaluated with Weibull statistics. Specimen survival or failure was examined visually and under a stereomicroscope, then fractographic analysis were conducted on sectioned specimens under the SEM. Finite Element Analysis (FEA) was performed using the mean FFLs and 300 N axial load on tri-layer models, respectively. SPSS 26.0 was used for statistical analysis and the significant level was pre-set as α = 0.05. Results EM showed significantly higher flexural strength and elastic modulus than the three resin-based composites (RBCs) (p < 0.001). Nevertheless, three energy dissipation parameters of RBCs were significantly higher than those of lithium disilicate, ranking TE > FS > GU > EM. The mean FFL showed a similar trend, ranking TE (353.93 ± 43.01 N) > GU (276.79 ± 34.24 N) > FS (255.33 ± 47.30 N) > EM (184.00 ± 76.92 N). EM presented the lowest Weibull parameters and the highest RSD values, while TE presented superior fatigue resistance and structural reliability. Distinct failure characteristics and stress distribution patterns between EM and three resin-matrix materials were found. Significance Distinct fatigue behaviours were discovered between lithium disilicate and resin-based materials, including the fatigue failure load, failure mode, and stress distribution pattern. Resin-based composites outperformed lithium disilicate in the cyclic fatigue test, among which the CAD/CAM indirect RBC material performed the best fatigue resistance. Energy dissipation parameters may serve as preliminary predictors to the fatigue properties.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (95)

Show source-provided references
1. Current status on lithium disilicate and zirconia: a narrative review10.1186/s12903-019-0838-x ↗
2. Current status and research trends of lithium disilicate in dentistry: a bibliometric analysis10.1016/j.prosdent.2020.08.012 ↗
3. Biocompatibility of dental casting alloys: a review10.1016/S0022-3913(00)80016-5 ↗
4. Assessment of corrosion resistance of cast cobalt- and nickel-chromium dental alloys in acidic environments
5. From artisanal to CAD-CAM blocks: state of the art of indirect composites10.1177/0022034516634286 ↗
6. The chemical and optical stability evaluation of injectable restorative materials under wet challenge10.1016/j.jdent.2024.105031 ↗
7. The mechanical, wear, antibacterial properties and biocompatibility of injectable restorative materials under wet challenge10.1016/j.jdent.2024.105025 ↗
8. Surface properties and wear resistance of injectable and computer-aided design/computer aided manufacturing-milled resin composite thin occlusal veneers
9. Are there universal restorative composites for anterior and posterior teeth?10.1016/j.jdent.2013.08.016 ↗
10. Comparison of mechanical and optical properties of a newly marketed universal composite resin with contemporary universal composite resins: An in vitro study10.1002/jemt.23985 ↗
11. Can a single composite resin serve all purposes?10.1038/sj.bdj.4812520 ↗
12. Improvement of aesthetics in a patient with tetracycline stains using the injectable composite resin technique: case report with 24-month follow-up10.1038/s41415-020-2405-x ↗
13. The injectable resin composite restorative technique: A case report10.1111/jerd.12650 ↗
14. Effect of storage conditions on mechanical properties of resin composite blanks for CAD/CAM crowns10.4012/dmj.2019-202 ↗
15. Fracture force of CAD/CAM resin composite crowns after in vitro aging10.1007/s00784-019-03099-1 ↗
16. Chairside CAD/CAM materials. Part 3: Cyclic fatigue parameters and lifetime predictions10.1016/j.dental.2018.03.024 ↗
17. Mechanical degradation of contemporary CAD/CAM resin composite materials after water ageing10.1016/j.dental.2021.04.002 ↗
18. Step-stress vs. staircase fatigue tests to evaluate the effect of intaglio adjustment on the fatigue behavior of simplified lithium disilicate glass-ceramic restorations10.1016/j.jmbbm.2020.104091 ↗
19. Loading frequencies up to 20Hz as an alternative to accelerate fatigue strength tests in a Y-TZP ceramic10.1016/j.jmbbm.2016.01.008 ↗
20. How oral environment simulation affects ceramic failure behavior10.1016/j.prosdent.2017.05.013 ↗
21. Laboratory methods to simulate the mechanical degradation of resin composite restorations10.1016/j.dental.2021.12.006 ↗
22. Clinically relevant approach to failure testing of all-ceramic restorations10.1016/S0022-3913(99)70103-4 ↗
23. Which dentine analogue material can replace human dentine for crown fatigue test?10.1016/j.dental.2022.11.020 ↗
24. Lithium disilicate restorations fatigue testing parameters: a systematic review10.1111/jopr.12376 ↗
25. Accelerated loading frequency does not influence the fatigue behavior of polymer infiltrated ceramic network or lithium disilicate glass-ceramic restorations10.1016/j.jmbbm.2020.103905 ↗
26. ADM guidance-ceramics: Fatigue principles and testing10.1016/j.dental.2017.09.006 ↗
27. Fatigue testing of biomaterials and their interfaces10.1016/j.dental.2017.01.012 ↗
28. Cyclic fatigue tests on non-anatomic specimens of dental ceramic materials: a scoping review10.1016/j.jmbbm.2021.104985 ↗
29. JA. Contributions of stress corrosion and cyclic fatigue to subcritical crack growth in a dental glass-ceramic10.1016/j.dental.2014.05.026 ↗
30. Fatigue of dental ceramics10.1016/j.jdent.2013.10.007 ↗
31. High load frequency at 20Hz: Its effects on the fatigue behavior of a leucite-reinforced glass-ceramic10.1016/j.jmbbm.2020.103769 ↗
32. Mechanical fatigue degradation of ceramics versus resin composites for dental restorations10.1016/j.dental.2014.01.003 ↗
33. Hygroscopic and hydrolytic effects in dental polymer networks10.1016/j.dental.2005.05.005 ↗
34. Long-term sorption and solubility of bulk-fill and conventional resin-composites in water and artificial saliva10.1016/j.jdent.2015.10.001 ↗
35. Evaluation of the color stability, water sorption, and solubility of current resin composites10.3390/ma15196710 ↗
36. Degradation, fatigue, and failure of resin dental composite materials10.1177/154405910808700802 ↗
37. Hygroscopic and hydrolytic effects in dental polymernetworks10.1016/j.dental.2005.05.005 ↗
38. Academy of Dental Materials guidance-Resin composites: Part II-Technique sensitivity (handling, polymerization, dimensional changes)10.1016/j.dental.2017.08.188 ↗
39. Beer · 2021
40. Energy dissipation capacities of CAD-CAM restorative materials: A comparative evaluation of resilience and toughness10.1016/j.prosdent.2018.05.003 ↗
41. Influence of accelerated ageing on the physical properties of CAD/CAM restorative materials10.1007/s00784-019-03101-w ↗
42. Darvell B. Materials Science for Dentistry: Ninth Edition. Materials Science for Dentistry: Ninth Edition. 2009:1-662.10.1533/9781845696672.1 ↗
43. Resin-based composites show similar kinetic profiles for dimensional change and recovery with solvent storage10.1016/j.dental.2015.06.003 ↗
44. Mechanical properties of resin-ceramic CAD-CAM materials after accelerated aging10.1016/j.prosdent.2017.08.016 ↗
45. ISO. International Organization for Standardization. ISO Standard 6872:2015. Dentistry — Ceramic materials. Geneva: ISO. 2015.
46. Static and fatigue mechanical behavior of three dental CAD/CAM ceramics10.1016/j.jmbbm.2016.01.023 ↗
47. Fatigue failure load of zirconia-reinforced lithium silicate glass ceramic cemented to a dentin analogue: Effect of etching time and hydrofluoric acid concentration10.1016/j.jmbbm.2017.09.028 ↗
48. Fatigue resistance of simplified CAD-CAM restorations: foundation material and ceramic thickness effects on the fatigue behavior of partially- and fully-stabilized zirconia10.1016/j.dental.2021.01.001 ↗
49. How does hydrofluoric acid etching affect the cyclic load-to-failure of lithium disilicate restorations?10.1016/j.jmbbm.2018.07.040 ↗
50. A method for obtaining and analyzing sensitivity data10.1080/01621459.1948.10483254 ↗
51. Collins · 1993
52. Fatigue failure load of an adhesively-cemented lithium disilicate glass-ceramic: Conventional ceramic etching vs etch & prime one-step primer10.1016/j.dental.2018.04.012 ↗
53. ADM guidance-Ceramics: guidance to the use of fractography in failure analysis of brittle materials10.1016/j.dental.2017.03.004 ↗
54. Lithium disilicate glass-ceramic vs translucent zirconia polycrystals bonded to distinct substrates: fatigue failure load, number of cycles for failure, survival rates, and stress distribution10.1016/j.jmbbm.2018.12.010 ↗
55. IA-FEMesh: an open-source, interactive, multiblock approach to anatomic finite element model development10.1016/j.cmpb.2008.12.003 ↗
56. Effect of occlusal contact size on interfacial stresses and failure of a bonded ceramic: FEA and monotonic loading analyses10.1016/j.dental.2007.06.017 ↗
57. Numerical fatigue analysis of premolars restored by CAD/CAM ceramic crowns10.1016/j.dental.2018.03.017 ↗
58. A new concept and finite-element study on dental bond strength tests10.1016/j.dental.2016.07.005 ↗
59. Alumina particle air-abrasion and aging effects: Fatigue behavior of CAD/CAM resin composite crowns and flexural strength evaluations10.1016/j.jmbbm.2021.104592 ↗
60. CAD-FEA modeling and analysis of different full crown monolithic restorations10.1016/j.dental.2018.06.024 ↗
61. Canine guidance reconstruction with ceramic or composite resin: A 3D finite element analysis and in vitro wear study10.1016/j.prosdent.2022.01.020 ↗
62. Fatigue failure load and finite element analysis of multilayer ceramic restorations10.1016/j.dental.2018.10.006 ↗
63. Effect of preparation design for all-ceramic restoration on maxillary premolar: a 3D finite element study10.1016/j.jpor.2018.04.002 ↗
64. Maximal bite force with centric and eccentric load10.1111/j.1365-2842.1982.tb01034.x ↗
65. Estimation of the risk of failure for an endodontically treated maxillary premolar with MODP preparation and CAD/CAM ceramic restorations10.1016/j.joen.2009.06.020 ↗
66. Aspects of adhesion tests on resin-glass ceramic bonding10.1016/j.dental.2017.06.013 ↗
67. Effect of thermal cycling on fracture toughness of CAD/CAM materials
68. Phenomena and mechanisms of crack propagation in glass-ceramics10.1016/j.jmbbm.2007.11.005 ↗
69. Lifetime-limiting strength degradation from contact fatigue in dental ceramics10.1177/00220345000790020501 ↗
70. Diffusion and concurrent solubility of self-adhering and new resin–matrix composites during water sorption/desorption cycles10.1016/j.dental.2010.10.014 ↗
71. Resin based restorative dental materials: characteristics and future perspectives10.1016/j.jdsr.2019.09.004 ↗
72. Nanofilled Resin Composite Properties and Clinical Performance: a review10.2341/17-208-T ↗
73. Resin-based dental composites: nanotechnology, properties and application
74. Academy of dental materials guidance-resin composites: Part I-mechanical properties10.1016/j.dental.2017.04.013 ↗
75. Resin-composite blocks for dental CAD/CAM applications10.1177/0022034514553976 ↗
76. Resin composite blocks via high-pressure high-temperature polymerization10.1016/j.dental.2011.12.003 ↗
77. Surface morphology and mechanical properties of new-generation flowable resin composites for dental restoration10.1016/j.dental.2011.08.596 ↗
78. Comparison of the wear and flexural characteristics of flowable resin composites for posterior lesions10.3109/00016357.2012.734405 ↗
79. Silane adhesion mechanism in dental applications and surface treatments: A review10.1016/j.dental.2017.09.002 ↗
80. Mechanical properties of nanohybrid resin composites containing various mass fractions of modified zirconia particles10.2147/IJN.S283742 ↗
81. Damping behaviour and mechanical properties of restorative materials for primary teeth10.3390/ma15217698 ↗
82. Interrelation among the handling, mechanical, and wear properties of the newly developed flowable resin composites10.1016/j.jmbbm.2018.09.019 ↗
83. Aging behavior of high-translucent CAD/CAM resin-based composite blocks10.1016/j.jmbbm.2020.104269 ↗
84. Influence of artificial aging on mechanical properties of six resin composite blocks for CAD/CAM application10.3390/coatings12060837 ↗
85. Reliability and properties of core materials for all-ceramic dental restorations10.1016/j.jdsr.2008.04.001 ↗
86. Development of a clinically validated bulk failure test for ceramic crowns10.1016/S0022-3913(10)60129-1 ↗
87. Interactive effect of indenter size and specimen thickness in Hertzian indentation test10.1016/j.dental.2010.02.001 ↗
88. Failure mode of dental restorative materials under Hertzian indentation10.1016/j.dental.2006.11.016 ↗
89. Failure behavior of glass ionomer cement under Hertzian indentation10.1016/j.dental.2008.02.002 ↗
90. Effect of elastic modulus mismatch on failure behaviour of glass ionomer cement under Hertzian indentation10.1016/j.dental.2011.11.004 ↗
91. Fatigue performance of adhesively luted glass or polycrystalline CAD-CAM monolithic crowns10.1016/j.prosdent.2020.03.032 ↗
92. Fatigue resistance of monolithic CAD/CAM ceramic crowns on human premolars10.1016/j.ceramint.2016.07.029 ↗
93. Pressable lithium disilicate ceramic versus CAD/CAM resin composite restorations in patients with moderate to severe tooth wear: Clinical observations up to 13 years10.1111/jerd.12947 ↗
94. Morphology and mechanical performance of dental crown designed by 3D-DCGAN10.1016/j.dental.2023.02.001 ↗
95. Morphology and fracture behavior of lithium disilicate dental crowns designed by human and knowledge-based AI10.1016/j.jmbbm.2022.105256 ↗