Biomechanical simulation of forces and moments of initial orthodontic tooth movement in dependence on the used archwire system by ROSS (Robot Orthodontic Measurement & Simulation System)
Source abstract
Abstract
OBJECTIVES: Aim of this study was to determine the forces and moments during simulated initial orthodontic tooth movements using a novel biomechanical test setup. METHODS: The test setup consisted of an industrial precision robot with a force-torque sensor, a maxillary model and a control computer and software. Forces and moments acting on the corresponding experimental tooth during the motion simulations were dynamically measured for two 0.016" NiTi round archwires (Sentalloy Light/Sentalloy Medium). Intrusive (#1), rotational (#2) and angular (#3) tooth movements were simulated by a control program based on the principle of force control and executed by the robot. The results were statistically analysed using K-S-test and Mann-Whitney U test with a significance level of α = 5%. RESULTS: Sentalloy Medium archwires generated higher forces and moments than the Sentalloy Light archwires in all simulations. In simulation #1 the mean initial forces/moments reached 1.442 N/6.781 Nmm for the Light archwires and 1.637 N/9.609 Nmm for the Medium archwires. In movement #2 Light archwires generated mean initial forces/moments of 0.302 N/-8.271 Nmm whereas Medium archwires generated 0.432 N/-9.653 Nmm. Simulation #3 showed mean initial forces/moments of -0.122 N/8.477 Nmm from the Light archwires compared to -0.300 N/11.486 Nmm for the Medium archwires. SIGNIFICANCE: The measured forces and moments were suitable for initial orthodontic tooth movement in simulations #2 and #3, however inadequate in simulation #1. Reduced archwire dimensions (<0.016″) should be selected for initial leveling of vertical malocclusions.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Orthodontics and Dentofacial Orthopedics · Temporomandibular Joint Disorders · Motor Control and Adaptation
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (57)
Show source-provided references
1. Robotic applications in orthodontics: changing the face of contemporary clinical care10.1155/2021/9954615 ↗
2. Comparison of conventional methods of simultaneous intrusion and retraction of maxillary anterior: a finite element analysis10.1080/14653125.2018.1525928 ↗
3. Three-dimensional modeling and finite element analysis in treatment planning for orthodontic tooth movement10.1016/j.ajodo.2010.09.020 ↗
4. Three-dimensional orthodontic force measurements10.1016/j.ajodo.2009.02.025 ↗
5. Physical properties of root cementum: Part 10. Comparison of the effects of invisible removable thermoplastic appliances with light and heavy orthodontic forces on premolar cementum. A microcomputed-tomography study10.1016/j.ajodo.2006.01.043 ↗
6. An experimental apparatus for the simulation of three-dimensional movements in orthodontics10.1016/0141-5425(92)90081-U ↗
7. Force systems from an ideal arch10.1016/S0002-9416(74)90332-7 ↗
8. Application of bioengineering devices for stress evaluation in dentistry: the last 10 years FEM parametric analysis of outcomes and current trends10.23736/S0026-4970.19.04263-8 ↗
9. Accuracy of clear aligners: a retrospective study of patients who needed refinement10.1016/j.ajodo.2017.11.028 ↗
10. Complete orthodontic load systems on teeth in a continuous full archwire: the role of triangular loop position10.1016/j.ajodo.2006.10.016 ↗
11. Quantification of three-dimensional orthodontic force systems of T-loop archwires10.2319/082509-484.1 ↗
12. Bioengineering methods of analysis and medical devices: a current trends and state of the art10.3390/ma13030797 ↗
13. Pure mandibular incisor intrusion: a finite element study to evaluate the segmented arch technique10.3390/ma12172784 ↗
14. Forces and moments applied during derotation of a maxillary central incisor with thinner aligners: an in-vitro study10.1016/j.ajodo.2016.08.020 ↗
15. Root resorptions in upper first premolars after application of continuous intrusive forces. Intra-individual study10.1007/BF01579165 ↗
16. The leveling effectiveness of self-ligating and conventional brackets for complex tooth malalignments10.1007/s00056-009-9916-z ↗
17. Measuring system for in vivo recording of force systems in orthodontic treatment-concept and analysis of accuracy10.1016/S0021-9290(98)00112-2 ↗
18. Force systems in the initial phase of orthodontic treatment -- a comparison of different leveling arch wires10.1007/s00056-006-0521-0 ↗
19. Gabersek · 2007
20. Graber · 2022
21. How accurate is Invisalign in nonextraction cases? Are predicted tooth positions achieved?10.2319/022717-147.1 ↗
22. Initial forces and moments delivered by removable thermoplastic appliances during rotation of an upper central incisor10.2319/033009-181.1 ↗
23. Three-dimensional analysis of orthodontic tooth movement based on XYZ and finite helical axis systems10.1093/ejo/cjm061 ↗
24. Comparison of two different initial archwires for tooth alignment during fixed orthodontic treatment-A randomized clinical trial10.4103/jos.JOS_17_20 ↗
25. Mechanistic insight into orthodontic tooth movement based on animal studies: a critical review
26. Force systems from orthodontic appliances: an analytical and experimental comparison10.1115/1.3138226 ↗
27. Hyalinization and root resorption during early orthodontic tooth movement in adolescents
28. Influence of archwire and bracket dimensions on sliding mechanics: derivations and determinations of the critical contact angles for binding10.1093/ejo/21.2.199 ↗
29. Digital design and fabrication of simulation model for measuring orthodontic force
30. Load deflection characteristics and force level of nickel titanium initial archwires10.2319/032511-213.1 ↗
31. Which orthodontic archwire sequence? A randomized clinical trial10.1093/ejo/cjl030 ↗
32. Infinite applications of finite element method10.4103/jios.jios_242_18 ↗
33. Alignment efficiency and discomfort of three orthodontic archwire sequences: a randomized clinical trial10.1179/14653121141218 ↗
34. Comparative assessment of forces generated during simulated alignment with self-ligating and conventional brackets10.1093/ejo/cjn107 ↗
35. Clinical effectiveness of Invisalign® orthodontic treatment: a systematic review10.1186/s40510-018-0235-z ↗
36. Effect of archwire qualities and bracket designs on the force systems during leveling of malaligned teeth
37. Proffit · 2007
38. Finite element analysis in orthodontics
39. Forces in initial archwires during leveling and aligning: an in-vitro study10.4103/2231-0762.192940 ↗
40. Some factors determining the evaluation of forces in orthodontics10.1016/0002-9416(57)90114-8 ↗
41. Tissue behavior during orthodontic tooth movement10.1016/0002-9416(60)90091-9 ↗
42. Clinical and histologic observations on tooth movement during and after orthodontic treatment10.1016/0002-9416(67)90118-2 ↗
43. Biological principles and reactions
44. Reitan · 1989 · 149
45. Bioprogressive therapy as an answer to orthodontic needs. Part II10.1016/0002-9416(76)90111-1 ↗
46. The use of finite element analysis in dentistry and orthodontics: critical points for model development and interpreting results10.1053/j.sodo.2020.06.014 ↗
47. Efficacy of clear aligners in controlling orthodontic tooth movement: a systematic review10.2319/061614-436.1 ↗
48. Sander · 2011
49. Sifakakis · 2017 · 382
50. Treatment outcome and efficacy of an aligner technique–regarding incisor torque, premolar derotation and molar distalization10.1186/1472-6831-14-68 ↗
51. Revolution in orthodontics: finite element analysis10.4103/2231-0762.178743 ↗
52. Initial arch wires for alignment of crooked teeth with fixed orthodontic braces
53. The development of orthodontics in the three dimensional finite element method
54. Wichelhaus · 2013
55. Stainless steel and NiTi torque archwires and apical root resorption10.1007/s00056-020-00244-4 ↗
56. CCR2(+) macrophages promote orthodontic tooth movement and alveolar bone remodeling
57. Neural regulation of alveolar bone remodeling and periodontal ligament metabolism during orthodontic tooth movement in response to therapeutic loading