Biomechanical, structural and biological characterisation of a new silk fibroin scaffold for meniscal repair
Source abstract
Abstract
Meniscal injury is typically treated surgically via partial meniscectomy, which has been shown to cause cartilage degeneration in the long-term. Consequently, research has focused on meniscal prevention and replacement. However, none of the materials or implants developed for meniscal replacement have yet achieved widespread acceptance or demonstrated conclusive chondroprotective efficacy. A redesigned silk fibroin scaffold, which already displayed promising results regarding biocompatibility and cartilage protection in a previous study, was characterised in terms of its biomechanical, structural and biological functionality to serve as a potential material for permanent partial meniscal replacement. Therefore, different quasi-static but also dynamic compression tests were performed. However, the determined compressive stiffness (0.56 ± 0.31 MPa and 0.30 ± 0.12 MPa in relaxation and creep configuration, respectively) was higher in comparison to the native meniscal tissue, which could potentially disturb permanent integration into the host tissue. Nevertheless, µ-CT analysis met the postulated requirements for partial meniscal replacement materials in terms of the microstructural parameters, like mean pore size (215.6 ± 10.9 µm) and total porosity (80.1 ± 4.3%). Additionally, the biocompatibility was reconfirmed during cell culture experiments. The current study provides comprehensive mechanical and biological data for the characterisation of this potential replacement material. Although some further optimisation of the silk fibroin scaffold may be advantageous, the silk fibroin scaffold showed sufficient biomechanical competence to support loads already in the early postoperative phase.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Knee injuries and reconstruction techniques · Silk-based biomaterials and applications · Adhesion, Friction, and Surface Interactions
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (66)
Show source-provided references
1. Trends in meniscus repair and meniscectomy in the united states, 2005–201110.1177/0363546513495641 ↗
2. In-vitro measurement of static pressure distribution in synovial joints-part I: tibial surface of the knee10.1115/1.3138409 ↗
3. Silk-based biomaterials10.1016/S0142-9612(02)00353-8 ↗
4. Design and mechanical evaluation of a novel fiber-reinforced scaffold for meniscus replacement10.1002/jbm.a.33260 ↗
5. Meniscal tears: the effect of meniscectomy and of repair on intraarticular contact areas and stress in the human knee. A preliminary report10.1177/036354658601400405 ↗
6. Knee menisci. Correlation between microstructure and biomechanics10.1097/00003086-198607000-00016 ↗
7. The meniscus: review of basic principles with application to surgery and rehabilitation
8. Autologous perichondral tissue for meniscal replacement10.1302/0301-620X.80B5.0800918 ↗
9. The strength of the menisci of the knee as it relates to their fine structure10.1302/0301-620X.52B3.564 ↗
10. Tissue Engineering of the meniscus10.1016/S0142-9612(03)00499-X ↗
11. Dynamic compressive behavior of human meniscus correlates with its extra-cellular matrix composition
12. Physical-chemical and biological characterization of silk fibroin-coated porous membranes for medical applications
13. Compressive moduli of the human medial meniscus in the axial and radial directions at equilibrium and at a physiological strain rate10.1002/jor.20573 ↗
14. Design of a free-floating polycarbonate-urethane meniscal implant using finite element modeling and experimental validation10.1115/1.4001892 ↗
15. Risk factors for symptomatic knee osteoarthritis fifteen to twenty-two years after meniscectomy10.1002/art.20489 ↗
16. Knee joint changes after meniscectomy10.1302/0301-620X.30B4.664 ↗
17. The contact area and pressure distribution pattern of the knee. A study of normal and osteoarthrotic knee joints10.3109/17453678008990887 ↗
18. Meniscal tissue regeneration using a collagenous biomaterial derived from porcine small intestine submucosa10.1053/jars.2001.20959 ↗
19. In vivo performance of a novel silk fibroin scaffold for partial meniscal replacement in a sheep model10.1007/s00167-014-3009-2 ↗
20. Correction to: in vivo performance of a novel silk fibroin scaffold for partial meniscal replacement in a sheep model10.1007/s00167-018-4878-6 ↗
21. Degumming of silk with different protease enzymes
22. Changes in articular cartilage after meniscectomy and meniscus replacement using a biodegradable porous polymer implant10.1007/s00167-010-1244-8 ↗
23. Partial versus total meniscectomy. A prospective, randomised study with long-term follow-up10.1302/0301-620X.74B1.1732238 ↗
24. Interspecies variation of compressive biomechanical properties of the meniscus10.1002/jbm.820290706 ↗
25. Medial meniscus replacement by a tendon autograft. Experiments in sheep10.1302/0301-620X.74B6.1447257 ↗
26. Loading of the knee joint during activities of daily living measured in vivo in five subjects10.1016/j.jbiomech.2010.03.046 ↗
27. Is the circumferential tensile modulus within a human medial meniscus affected by the test sample location and cross-sectional area?10.1002/jor.1100180614 ↗
28. Tibiofemoral contact mechanics after serial medial meniscectomies in the human cadaveric knee10.1177/0363546506286786 ↗
29. Evaluation of a porous polyurethane scaffold in a partial meniscal defect ovine model10.1016/j.arthro.2010.02.033 ↗
30. Epidemiology of athletic knee injuries: a 10-year study10.1016/j.knee.2006.01.005 ↗
31. Biomechanics
32. Anatomy
33. The inflammatory responses to silk films in vitro and in vivo10.1016/j.biomaterials.2004.02.047 ↗
34. Successful total meniscus reconstruction using a novel fiber-reinforced scaffold: a 16- and 32-week study in an ovine model10.1177/0363546515595065 ↗
35. Evaluation of platelet-rich plasma and hydrostatic pressure regarding cell differentiation in nucleus pulposus tissue engineering10.1002/term.524 ↗
36. Meniscus replacement using Hoffa's infrapatellar fat bodies--initial clinical results10.1007/BF02588774 ↗
37. Structure and function of articular cartilage and meniscus
38. Meniscus transplantation: indications, techniques, clinical outcomes
39. Macrophage responses to silk10.1016/S0142-9612(03)00158-3 ↗
40. Negative outcomes of poly(l-lactic acid) fiber-reinforced scaffolds in an ovine total meniscus replacement model10.1089/ten.tea.2016.0143 ↗
41. Finite element analysis of the effect of meniscal tears and meniscectomies on human knee biomechanics10.1016/j.clinbiomech.2005.01.009 ↗
42. Biomechanical and cellular segmental characterization of human meniscus: building the basis for tissue engineering therapies10.1016/j.joca.2014.07.001 ↗
43. The current state of meniscal allograft transplantation and replacement10.1016/S0968-0160(02)00139-4 ↗
44. A clinical study of collagen meniscus implants to restore the injured meniscus10.1097/00003086-199910001-00027 ↗
45. Biomaterials in search of a meniscus substitute10.1016/j.biomaterials.2014.01.017 ↗
46. Knee osteoarthritis after meniscectomy: prevalence of radiographic changes after twenty-one years, compared with matched controls10.1002/1529-0131(199804)41:4<687::AID-ART16>3.0.CO;2-2 ↗
47. Biomechanical comparison of menisci from different species and artificial constructs10.1186/1471-2474-14-324 ↗
48. In vitro evaluation of the inflammatory potential of the silk fibroin10.1002/(SICI)1097-4636(19990905)46:3<382::AID-JBM11>3.0.CO;2-R ↗
49. Optimization strategies on the structural modeling of gelatin/chitosan scaffolds to mimic human meniscus tissue10.1016/j.msec.2013.07.036 ↗
50. Arthroscopic partial meniscectomy: a 12-year follow-up and two-step evaluation of the long-term course10.1016/S0749-8063(98)70031-3 ↗
51. Effect of partial meniscectomy at the medial posterior horn on tibiofemoral contact mechanics and meniscal hoop strains in human knees10.1002/jor.22010 ↗
52. Increase in cell migration and angiogenesis in a composite silk scaffold for tissue-engineered ligaments10.1002/jor.20752 ↗
53. An analysis of variance test for normality (complete samples)10.2307/2333709 ↗
54. Viscoelastic properties of a synthetic meniscus implant10.1016/j.jmbbm.2013.08.021 ↗
55. Meniscus replacement10.1016/S0278-5919(20)30112-5 ↗
56. Regeneration of meniscal cartilage with use of a collagen scaffold. Analysis of preliminary data10.2106/00004623-199712000-00002 ↗
57. Meniscal replacement in dogs. Tissue regeneration in two different materials with similar properties10.1002/jbm.b.30406 ↗
58. Tensile stress-strain characteristics of the human meniscal material10.1016/0021-9290(94)00081-E ↗
59. Transplantation of viable meniscal allograft. Survivorship analysis and clinical outcome of one hundred cases10.2106/00004623-200504000-00004 ↗
60. Tissue ingrowth after implantation of a novel, biodegradable polyurethane scaffold for treatment of partial meniscal lesions10.1177/0363546511398040 ↗
61. Failure properties and strain distribution analysis of meniscal attachments10.1016/j.jbiomech.2007.01.015 ↗
62. Meniscus regeneration in a rabbit partial meniscectomy model10.1089/ten.1999.5.327 ↗
63. Friction properties of a new silk fibroin scaffold for meniscal replacement10.1016/j.triboint.2017.01.038 ↗
64. Effect on tissue differentiation and articular cartilage degradation of a polymer meniscus implant – a 2-year follow-up study in dogs10.1177/0363546508319900 ↗
65. Macro/microporous silk fibroin scaffolds with potential for articular cartilage and meniscus tissue engineering applications10.1016/j.actbio.2011.09.037 ↗
66. Chondroprotective effects of a polycarbonate-urethane meniscal implant: histopathological results in a sheep model10.1007/s00167-010-1210-5 ↗