journal article·2007-09

UV-cured FRP joint thickness effect on coupled composite pipes

Jerry Alan Peck, Randy A. Jones, Su-Seng Pang, Guoqiang Li, Brett H. Smith

Composite Structures· Volume 80· Issue 2
Publisher page

Abstract

Abstract In this study, 36 FRP composite pipes were joined with various layers of fiber-reinforced UV curing vinylester. Twelve of the composite pipes were joined with an eight-layer weld, 12 with five layers and 12 with three layers; each configuration used exactly one layer of E-glass woven fabric with the remaining layers being comprised of chopped strand mat of various widths. The joined pipes were cured with UV lamps at 80 milli-Watts per square centimeter. The mechanical properties of the cured pipe joints were evaluated by conducting internal pressure testing and simply supported four-point bending testing. The effect of joint thickness on the internal pressure rating, ultimate bending load, and stiffness was evaluated to determine the role of joint thickness in under-curing of UV curing vinylesters. There was a direct correlation observed between joint thickness and internal pressure rating. The five-layer and three-layer joints each performed better than the eight-layer joint in bursting. The mechanism for variation in the residual properties was found to be the degree of cure and was validated by finite element analysis that utilized a composite model that simulates variable cure.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Mechanical Behavior of Composites · Material Properties and Processing · Epoxy Resin Curing Processes

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (13)

Show source-provided references
1. Koch GH, Brongers PH, Thompson NG, Virmani TP, Payer JH. Corrosion cost and preventive strategies in the United States. Office of Infrastructure Research and Development. Federal Highway Administration, Report No. FHWA-RD-01-XXX, September 2001.
2. Fast joining of composite pipes using UV curing FRP composites10.1002/pc.20024 ↗
3. Ultraviolet curing of acrylic systems: real-time Fourier transform infrared, mechanical, and fluorescence studies10.1002/pola.10515 ↗
4. Jönsson S, Hasselgren C. Secrets of the dark. Fusion UV Systems, Inc., 910 Clopper Road, Gaithersburg, MD 20878. Available from: http://www.fusionuv.com.
5. Real-time FTIR-ATR spectroscopy to study the kinetics of ultrafast photopolymerization reactions induced by monochromatic UV light10.1016/S0924-2031(98)00070-8 ↗
6. Effect of UV light source intensity and spectral distribution on the photopolymerization reactions of a multifunctional acrylated monomer10.1016/S1010-6030(02)00172-7 ↗
7. Photoinduced alignment of polymer liquid crystals containing azobenzene moieties in the side chain. 1. Effect of light intensity on alignment behavior10.1021/ma970943p ↗
8. Real-time fourier transform infrared study of the free-radical ultraviolet-induced polymerization of a hybrid sol–gel. II. The effect of physicochemical parameters on the photopolymerization kinetics10.1002/pola.10623 ↗
9. Chain-length-dependent termination rate processes in free-radical polymerizations. 1. Theory10.1021/ma00035a026 ↗
10. The effect of curing light intensity and test temperature on the dynamic mechanical properties of two polymer composites10.1046/j.1365-2842.1999.00432.x ↗
11. Light intensity effect on UV cured FRP coupled composite pipe joints10.1016/j.compstruct.2003.10.003 ↗
12. Wells K. Welding procedures for FIBERBOND® fiberglass piping systems. EDO Specialty Plastics, Baton Rouge, Louisiana. Available from: http://www.fiberbond.com, October 2002.
13. Fast repair of laminated beams using UV curing composites10.1016/S0263-8223(02)00292-1 ↗