journal article·2017-09-01

Effect of Self-Contained Breathing Apparatus (SCBA) on Heat Loss in Structural Firefighter Turnout Suits

Meredith McQuerry, Emiel DenHartog, Roger Barker

AATCC Journal of Research· Volume 4· Issue 5
Publisher page

Abstract

The purpose of this research was to determine the effect of firefighter's self-contained breathing apparatus (SCBA) on heat loss through clothing ventilation openings in structural firefighter turnout suits. Passive and active ventilation openings were fabricated into structural turnout suits and tested with and without the SCBA to determine the effect on clothing ventilation. Turnout suits were evaluated under two test conditions on a sweating manikin to measure thermal and evaporative resistance. A predicted total heat loss (THL) value was calculated for each suit and compared to a control turnout without ventilation openings. A significant improvement in heat loss was measured when the SCBA harness, mask, and thermal hood were removed from the structural ensemble. Results showed the SCBA harness significantly decreased heat loss in firefighter turnouts.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Occupational Health and Performance · Fire dynamics and safety research · Ergonomics and Musculoskeletal Disorders

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Florida State University

North Carolina State University

References (19)

Show source-provided references
1. Rossi R. · Tech. Text. · 2005 · 48 · 1
2. 10.17265/2159-5313/2016.09.00310.17265/2159-5313/2016.09.003 ↗
3. 10.17265/2159-5313/2016.09.00310.17265/2159-5313/2016.09.003 ↗
4. Fulmer D.B., Jirka G.P. Fire Engineering, August 2004, pp 1–9.
5. 10.1080/00140139.2011.62279710.1080/00140139.2011.622797 ↗
6. 10.1016/S0003-6870(01)00007-210.1016/S0003-6870(01)00007-2 ↗
7. 10.1007/BF0101522410.1007/BF01015224 ↗
8. 10.1007/s00421-008-0924-210.1007/s00421-008-0924-2 ↗
9. 10.1177/004051751559502910.1177/0040517515595029 ↗
10. Smith C.J. · Eur. J. Appl. Physiol. · 2011 · 111 · 110.1007/s00421-010-1744-8 ↗
11. Kurlick G. M. · Mon. Labor Rev. · 2012 · 134 · 18
12. 10.14504/ajr.3.3.210.14504/ajr.3.3.2 ↗
13. 10.1177/00405175800500030810.1177/004051758005000308 ↗
14. 10.1177/00405175820520011010.1177/004051758205200110 ↗
15. ASTM F1291-10. ASTM International, West Conshohocken, PA, USA, 2010, www.astm.org.
16. ASTM F2370-10. ASTM International, West Conshohocken, PA, USA, 2010, www.astm.org.
17. Ross K., Barker R., Deaton A.S. In Performance of Protective Clothing and Equipment: Emerging Issues and Technologies; Shepherd A.M., Ed. ASTM International: West Conshohocken, PA, 2012; pp 27–47.
18. McCullough E. A · ASHRAE Trans. · 1985 · 91 · 29
19. 10.1108/RJTA-14-04-2010-B00310.1108/RJTA-14-04-2010-B003 ↗