journal article·2004-05

Tissue engineered composite of a woven fabric scaffold with tendon cells, response on mechanical simulation in vitro

E. Karamuk, J. Mayer, G. Raeber

Composites Science and Technology· Volume 64· Issue 6
Publisher page

Abstract

Abstract In reconstructive surgery, complications of implanted textiles are often associated with mechanical and structural incompatibility between implant and host tissue. Ingrowing cells and maturation of an extracellular matrix form together with the textile a vital/avital composite and by this change mechanical properties of the textile implant. Thus, a profound understanding is required to consider these effects in the design of the implant. Mechanical stimulation in tissue engineering is proposed as a viable experimental technique to investigate structure-properties relations to design vital/avital composites. Therefore, the aim of this study was to investigate the effects of cyclic mechanical stimulation (2% sinusoidal strain, 1 h at 0.5 Hz stimulation followed by 6 h recreation phase at 0.01 Hz) on a vital/avitat composite that consists of a woven fabric as scaffold and confluent tendon fibroblasts as the vital matrix. The force response during the exertion phase could be correlated to dynamic orientation of f-actin filaments in the cytosceleton.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Tendon Structure and Treatment · Electrospun Nanofibers in Biomedical Applications · Bone Tissue Engineering Materials

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (19)

Show source-provided references
1. de Haan J. Structure-property relations in plain weft-knitted fabric reinforced composites (KFRCs) preparing for load bearing implants: experimental study and beam model approach. PhD Thesis, ETH Zurich, Department of Materials, 1999.
2. The effect of motion on the tissue response to polymeric fiber implants10.1016/0267-6605(94)90007-8 ↗
3. Meshes within the abdominal wall10.1007/s001040050737 ↗
4. Influence of polyclactin-coating on functional and morphological parameters of polypropylene-mesh modifications for abdominal wall repair10.1016/S0142-9612(98)00211-7 ↗
5. Functional and morphological evaluation of different polypropylene-mesh modifications for abdominal wall repair10.1016/S0142-9612(98)00115-X ↗
6. Pathology of traditional surgical nets for hernia repair after long-term implantations in humans10.1007/s001040051011 ↗
7. Biomechanics of human common carotid artery and design of a novel hybrid textile compliant vascular grafts10.1002/(SICI)1097-4636(19970305)34:3<341::AID-JBM9>3.0.CO;2-K ↗
8. On the correlation between the failure of vascular grafts and their structural and material properties10.1002/jbm.820200309 ↗
9. Bicomponent vascular graft consisting of synthetic absorbable fibers. I. in vitro study10.1002/jbm.820271013 ↗
10. Comparative investigation on the biomechanical properties of ligament replacement in the sheep knee using six different ligament prostheses10.1016/0267-6605(94)90004-3 ↗
11. Analysis of retrieved polymer fiber based replacements for the ACL10.1016/S0142-9612(00)00114-9 ↗
12. Reconstruction of rabbit achilles tendon with three bioabsorbable materials10.1007/s007760050161 ↗
13. Prosthetic replacement of the anterior cruciate ligament10.1016/0267-6605(94)90003-5 ↗
14. The stiffness of bone marrow cell-knit composites is increased during mechanical loading10.1016/S0142-9612(01)00069-2 ↗
15. Tendons and ligaments
16. The control of cell division by tension or diffusion10.1038/274052a0 ↗
17. Tensional homeostasis in dermal fibroblasts10.1002/(SICI)1097-4652(199806)175:3<323::AID-JCP10>3.0.CO;2-6 ↗
18. Theoretical study of intracellular stress fiber orientation under cyclic deformation10.1016/S0021-9290(00)00114-7 ↗
19. Oblique alignment of stress fibers in cells reduces the mechanical stress in cyclically deforming fields10.1016/S0171-9335(98)80076-9 ↗