Use of a Fluorescent Indicator in Monitoring Underlying Corrosion on Coated Aluminum 2024-T4
Source abstract
Abstract
A fluorescent indicator (FI) can be used to monitor the underlying corrosion on metal substrates based on sensing pH changes caused by corrosion reactions. One coumarin derivative was chosen as FI and added to a coated-aluminum system. The initial state of the coating system is fluorescent under UV light and it changes to nonfluorescent at the site of corrosion. The effects of the fluorescent indicator on the fluorescent intensity and protectiveness of the coating system are discussed. Electrochemical impedance spectroscopy (EIS) was used to estimate the protectiveness of the coating and interface corrosion reactions between the metal and coating. This was correlated with the fluorescent intensity change of the coating. Based on the impedance measured by EIS, the coating failed shortly after immersing into the 3.5% sodium chloride solution. After , pH-induced fluorescent quenching points began to appear. Scanning electron microscopy and energy-dispersive spectroscopy of selected specimens indicated that the quenching point was the corrosion site. Several coating thicknesses were examined, and based on these tests the optimal coating thickness was determined to be about .
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Corrosion Behavior and Inhibition · Concrete Corrosion and Durability · Analytical Chemistry and Sensors
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References
Reference metadata was not supplied for this record.