article·2001-01-01

A Study of Capacity Fade in Cylindrical and Prismatic Lithium-Ion Batteries

Robert S. Rubino, Hong Gan, Esther S. Takeuchi

Publisher page

Abstract

Identical electrodes wound in both a cylindrical and a prismatic configuration provided different capacity fade rates. At the completion of 300 cycles with a C/2 charge and 1C discharge, the prismatic cells faded 24% and the cylindrical cells faded 16%. In the cylindrical-type cell, the fade was primarily caused by a reduction in the capacity of the cathode. The higher fade rate in the prismatic cell was attributed to lower cell stack pressure which resulted in more anode swelling during cycling. The increased porosity of the anode in this cell reduced the integrity of the electrical conduction network causing many graphite particles to become isolated or less accessible. © 2001 The Electrochemical Society. All rights reserved.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Advancements in Battery Materials · Advanced Battery Technologies Research · Advanced Battery Materials and Technologies

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References