Operando Analysis of Thermal Runaway in Lithium Ion Battery during Nail-Penetration Test Using an X-ray Inspection System
Source abstract
Abstract
The thermal runaway of a lithium ion battery (LIB) during a nail-penetration test was investigated using an LIB internal short circuit observation system equipped with an X-ray scanner (LiSC scanner). Using high-speed moving images and high-precision voltage measurements, the layer-by-layer internal short circuit caused by the nail was clearly observed during nail motion. Following this motion, gas generation outside the cell, which is well-known in thermal runaway, was observed. The main causes of smoke are speculated to be the boiling of the electrolyte and/or decomposition of the active materials owing to heating by the short circuit current. The initial behavior of the short circuit before gas generation was clearly observed. Therefore, gas generation, which is well-known to indicate an internal short circuit of the cell, and the electrical behavior of the short circuit during the nail-penetration test were observed separately. This LiSC scanner allowed us to analyze the details of the internal short circuit of the cell, and it is expected to lead to significant advancements in the safety of LIBs.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Advanced Battery Technologies Research · Advancements in Battery Materials · Advanced Battery Materials and Technologies
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (26)
Show source-provided references
1. 10.1016/j.jpowsour.2005.12.00210.1016/j.jpowsour.2005.12.002 ↗
2. 10.1149/2.F03122if10.1149/2.F03122if ↗
3. 10.1039/c0ee00831a10.1039/c0ee00831a ↗
4. Assessing the safety of lithium-ion batteries10.1021/cen-09106-scitech1 ↗
5. Secondary cells and batteries containing alkaline or other non-acid electrolytes - Safety requirements for portable sealed secondary lithium cells, and for batteries made from them, for use in portable applications - Part 2: Lithium systems, IEC 62133-2:2017, 2017-02-07.
6. Safety tests for portable Lithium Ion secondary cells and batteries for use in portable electronic applications, JIS C 8714:2007, 2007-11-12.
7. Secondary lithium cells and batteries for use in industrial applications - Part 2: Tests and requirements of safety, JIS C 8715-2:2012, 2012-07-20.
8. 10.1016/j.jpowsour.2013.11.06910.1016/j.jpowsour.2013.11.069 ↗
9. 10.1016/j.apenergy.2016.04.01610.1016/j.apenergy.2016.04.016 ↗
10. 10.1016/j.apenergy.2016.08.10110.1016/j.apenergy.2016.08.101 ↗
11. 10.1016/j.energy.2017.02.01710.1016/j.energy.2017.02.017 ↗
12. 10.1016/j.jpowsour.2009.02.07010.1016/j.jpowsour.2009.02.070 ↗
13. 10.1016/j.jpowsour.2013.09.02210.1016/j.jpowsour.2013.09.022 ↗
14. 10.1016/j.jpowsour.2016.11.01810.1016/j.jpowsour.2016.11.018 ↗
15. Ichimura M. , The Safety Characteristics of Lithium-ion Batteries for Mobile Phones and the Nail Penetration Test, 29th Telecommunications Energy Conference (2007) 687–692.10.1109/INTLEC.2007.4448869 ↗
16. 10.1063/1.497565310.1063/1.4975653 ↗
17. 10.1149/2.1071501jes10.1149/2.1071501jes ↗
18. 10.1149/2.1031507jes10.1149/2.1031507jes ↗
19. 10.1149/07401.0071ecst10.1149/07401.0071ecst ↗
20. 10.1016/j.jpowsour.2014.11.01710.1016/j.jpowsour.2014.11.017 ↗
21. 10.3390/batteries302001410.3390/batteries3020014 ↗
22. 10.1149/2.0921509jes10.1149/2.0921509jes ↗
23. 10.3390/s11100994210.3390/s111009942 ↗
24. 10.1038/ncomms792410.1038/ncomms7924 ↗
25. 10.1016/j.jpowsour.2018.04.09210.1016/j.jpowsour.2018.04.092 ↗
26. 10.1149/2.0231510jes10.1149/2.0231510jes ↗