article·2008-01-01

Chlorine Poisoning of SOFC Ni-Cermet Anodes

Kengo Haga, Yusuke Shiratori, Kohei Ito, Kazunari Sasaki

Publisher page

Abstract

Poisoning effects by chlorine compounds, including and HCl, to typical electrolyte-supported solid oxide fuel cells (SOFCs) with Ni–scandia-stabilized zirconia cermet anodes have been evaluated. The degradation rate of cell voltage poisoned by was estimated to be ca. . Chlorine degradation rate increased with increasing concentration. Microstructural change associated with the formation of nickel nanoparticles on zirconia grains, probably via sublimation, was observed after poisoning tests, whereas a partial recovery of cell voltage by removing chlorine from the fuels indicates that the chlorine poisoning is partially reversible. Thermochemical calculations, microstructural analysis, and electrochemical characterizations have revealed that the poisoning phenomena for Ni-based cermet anodes caused by chlorine compounds can be explained by the mixed adsorption-type and sublimation-type poisoning mechanism.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Advancements in Solid Oxide Fuel Cells · Electrocatalysts for Energy Conversion · Electronic and Structural Properties of Oxides

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References

Reference metadata was not supplied for this record.