article·2005-01-01

Probing the Dealloying Critical Potential

Aziz Dursun, Dylan Pugh, Sean G. Corcoran

Publisher page

Abstract

One of the important characteristics of dealloying systems is the location of the critical potential which marks the transition from a "passivated" alloy surface to the sustained formation of a bicontinuous porous structure. A steady-state method for accurately determining the dealloying critical potential is compared with the more traditional approach of extrapolation from anodic polarization data. Misinterpretation in the literature of short-term potential hold data is discussed in light of these results. The dealloying critical potentials for and were 0.80, 0.94, and 1.01 V (normal hydrogen electrode), respectively. The polarization data is shown to overestimate these values by 100 mV. Morphological investigations confirm the presence of porosity for a potential hold only 10 mV above the critical potential. For alloys with compositions between 70-80 atom % Ag, the critical potential increased by 20 mV per atom % decrease in the Ag composition. Long-term current fluctuations were observed during the potential hold experiments that suggest the presence of a surface corrosion instability occurring over 1-5% of the total surface area. © 2005 The Electrochemical Society. All rights reserved.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Nanoporous metals and alloys · Electrocatalysts for Energy Conversion · Anodic Oxide Films and Nanostructures

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References

Reference metadata was not supplied for this record.