journal article·1991-01-01

Nernstian Hydrogen Sensor Using BaCeO3 ‐ Based , Proton‐Conducting Ceramics Operative at 200°–900°C

H. Iwahara, H. Uchida, K. Ogaki, H. Nagato

Publisher page

Abstract

A hydrogen concentration cell was constructed by using a high‐temperature, proton‐conducting oxide ceramic based on . This Nernstian hydrogen sensor gave rise to a stable electromotive force in correspondence to a hydrogen partial pressure, and the response speed was fast. Because of its high protonic conductivity, the working temperature range of the sensor was very wide, from 200° to 900°C. At 200°C, this sensor had a good selectivity to hydrogen.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Gas Sensing Nanomaterials and Sensors · Advanced Chemical Sensor Technologies · Analytical Chemistry and Sensors

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Synthetic Crystal Research Laboratory, Nagoya University, Chikusa‐ku, Nagoya 464‐01, Japan

Department of Applied Chemistry, Osaka University, Suita, Osaka 565, Japan

Department of Environmental Chemistry and Technology, Tottori University, Koyama‐cho, Tottori 680, Japan

References

Reference metadata was not supplied for this record.