Effects of Trigger Method on Fire Propagation during the Thermal Runaway Process in Li-ion Batteries
Source abstract
Abstract
Lithium-ion batteries are prone to fire hazards due to the possibility of thermal runaway propagation. During battery product development and subsequent safety tests for design validation and safety certification, the thermal runaway onset is triggered by various test methods such as nail penetration, thermal ramp, or external short circuit. This failure initiation method affects the amount of heat contributions and the composition of gas generations. This study compares two such trigger methods, external heating and using a thermally-activated internal short circuit device (ISCD). The effects of the trigger method on total heat generation are experimentally investigated within 18650 cylindrical cells at single cell level as well as at multiple cell configuration level. The severity of failure was observed to be worse for cells with ISCDs at single cell level, whereas quite the opposite results were observed at multiple cell configuration level. A preliminary numerical analysis was performed to better understand the battery safety performance with respect to thermal runaway trigger methods and heat transfer conditions.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Advanced Battery Technologies Research · Advanced Battery Materials and Technologies · Advancements in Battery Materials
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (34)
Show source-provided references
1. Thermal runaway mechanism of lithium ion battery for electric vehicles: a review10.1016/j.ensm.2017.05.013 ↗
2. A critical review of lithium-ion battery safety testing and standards10.1016/j.applthermaleng.2023.121014 ↗
3. UL 9540A · 2022
4. Abuse response of batteries subjected to mechanical impact
5. Tracking internal temperature and structural dynamics during nail penetration of lithium-ion cells10.1149/2.1501713jes ↗
6. Internal short circuit and failure mechanisms of lithium-ion pouch cells under mechanical indentation abuse conditions:An experimental study10.1016/j.jpowsour.2020.227939 ↗
7. Lamb · ECS Meeting Abstracts · 2020 · MA2020-01 · 10410.1149/MA2020-011104mtgabs ↗
8. Internal short circuit trigger method for lithium-ion battery based on shape memory alloy10.1149/2.0731713jes ↗
9. Transport processes in a Li-ion cell during an internal short-circuit10.1149/1945-7111/ab995d ↗
10. Modeling extreme deformations in lithium ion batteries10.1016/j.etran.2020.100065 ↗
11. Coupled mechanical–electrochemical–thermal study on the short-circuit mechanism of lithium-ion batteries under mechanical abuse10.1149/1945-7111/aba96f ↗
12. Investigating the relationship between internal short circuit and thermal runaway of lithium-ion batteries under thermal abuse condition10.1016/j.ensm.2020.10.020 ↗
13. Thermal runaway of lithium-ion batteries without internal short circuit10.1016/j.joule.2018.06.015 ↗
14. Thermal model of cylindrical and prismatic lithium-ion cells10.1149/1.1377592 ↗
15. Model-based thermal runaway prediction of lithium-ion batteries from kinetics analysis of cell components10.1016/j.apenergy.2018.06.126 ↗
16. A comprehensive numerical and experimental study for the passive thermal management in battery modules and packs10.1149/1945-7111/ac9ee4 ↗
17. A review of lithium-ion battery thermal runaway modeling and diagnosis approaches10.3390/pr10061192 ↗
18. Numerical investigation of thermal runaway mitigation through a passive thermal management system10.1016/j.jpowsour.2019.04.091 ↗
19. Thermal runaway propagation behavior within 18,650 lithium-ion battery packs: a modeling study10.1016/j.est.2020.101668 ↗
20. Development of a computational fluid dynamics simulation framework for aerothermal analyses of electric vehicle battery packs10.1115/1.4063800 ↗
21. A three-dimensional thermal abuse model for lithium-ion cells10.1016/j.jpowsour.2007.04.018 ↗
22. A coupled electrochemical-thermal failure model for predicting the thermal runaway behavior of lithium-ion batteries10.1149/2.0311816jes ↗
23. Multi-field interpretation of internal short circuit and thermal runaway behavior for lithium-ion batteries under mechanical abuse10.1016/j.energy.2022.126027 ↗
24. A multiphysics understanding of internal short circuit mechanisms in lithium-ion batteries upon mechanical stress abuse10.1016/j.ensm.2021.12.018 ↗
25. Comprehensive battery safety risk evaluation: aged cells versus fresh cells upon mechanical abusive loadings10.1002/aenm.202300368 ↗
26. Safety issues caused by internal short circuits in lithium-ion batteries10.1039/C8TA08997C ↗
27. Toward the performance evolution of lithium-ion battery upon impact loading10.1016/j.electacta.2022.141192 ↗
28. On the damage and performance degradation of multifunctional sandwich structure embedded with lithium-ion batteries under impact loading10.1016/j.jpowsour.2023.233509 ↗
29. Modeling cell venting and gas-phase reactions in 18650 lithium ion batteries during thermal runaway10.1016/j.jpowsour.2021.229496 ↗
30. Simulating onset and evolution of thermal runaway in Li-ion cells using a coupled thermal and venting model10.1016/j.apenergy.2020.114972 ↗
31. Keyser · 2015
32. Characterising thermal runaway within lithium-ion cells by inducing and monitoring internal short circuits10.1039/C7EE00385D ↗
33. Investigating the role of energy density in thermal runaway of lithium-ion batteries with accelerating rate calorimetry10.1149/1945-7111/ac0699 ↗
34. Modelling Li-Ion cell thermal runaway triggered by an internal short circuit device using an efficiency factor and arrhenius formulations10.1149/2.0341704jes ↗