Current Interrupt Technique to Fully Characterize PEMWE Cells
Source abstract
Abstract
It is common practice to characterize cells in polymer electrolyte membrane water electrolysis (PEMWE) using electrochemical impedance spectroscopy (EIS) and Tafel analysis, which require special equipment and operation procedures. Additionally, these techniques are not suitable for large industrial size cells with very low impedances. We present a simpler approach based on a novel evaluation of the current interrupt (CI) technique. The CI technique utilizes the voltage response after an instantaneous drop of electric current to identify the ohmic resistance R Ω, charge transfer resistance R ct and double-layer capacity C dl in a simplified equivalent circuit (EC) of the cell. A direct link to results of typical EIS and Tafel analysis can be defined by using the improved CI method which considers a non-linear activation resistance instead of a constant charge transfer resistance. Thereby, access to equivalent information as the established standard method is granted, while being applicable to all cell and stack sizes without requiring special equipment (e.g. impedance spectrometer). The agreement with experimental data is significantly improved over the assumption of a constant charge transfer coefficient. Consistency of the proposed interpretation with explicit EIS and Tafel analysis is demonstrated and options for industrial application of the evaluation scheme are discussed.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Energy Harvesting in Wireless Networks · Quantum-Dot Cellular Automata · Radio Frequency Integrated Circuit Design
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (36)
Show source-provided references
1. Bessarabov · 201610.1201/b19096 ↗
2. The history of water electrolysis from its beginnings to the present10.1016/B978-0-12-819424-9.00010-0 ↗
3. Godula-Jopek · 201510.1002/9783527676507 ↗
4. Bessarabov · 2018 · Vol. 210.1016/C2018-0-02127-1 ↗
5. Hydrogen production by PEM water electrolysis – A review10.1016/j.mset.2019.03.002 ↗
6. Thomassen · 2022 · p. 19910.1016/B978-0-12-819424-9.00013-6 ↗
7. Development of reference hardware for harmonised testing of PEM single cell fuel cells10.2760/83818 ↗
8. O’hayre · 201610.1002/9781119191766 ↗
9. Chronopotentiometric response of an ion-exchange membrane in the underlimiting current-range. Transport phenomena within the diffusion layers10.1016/S0376-7388(96)00210-4 ↗
10. Electrochemical impedance of ion-exchange membranes with interfacial charge transfer resistances10.1021/acs.jpcc.5b12087 ↗
11. Identification of characteristic time constants in the initial dynamic response of electric double layer capacitors from high-frequency electrochemical impedance10.1016/j.jpowsour.2018.07.015 ↗
12. Breitkopf · 2017
13. Temperature and Performance Inhomogeneities in PEM Electrolysis Stacks with Industrial Scale Cells10.1149/1945-7111/accb68 ↗
14. Orazem · 200810.1002/9780470381588 ↗
15. Analysis of gas permeation phenomena in a PEM water electrolyzer operated at high pressure and high current density10.1149/1945-7111/abaa68 ↗
16. Novel Analytical Approach for Parameters Identification of PEM Electrolyzer10.1109/TII.2021.3132941 ↗
17. Automized parametrization of PEM and alkaline water electrolyzer polarisation curves10.1016/j.ijhydene.2022.07.085 ↗
18. Proton exchange membrane fuel cell stack consistency: Evaluation methods, influencing factors, membrane electrode assembly parameters and improvement measures10.1016/j.enconman.2022.115651 ↗
19. Yuan · 201010.1007/978-1-84882-846-9 ↗
20. Zhang · 200810.1007/978-1-84882-846-9 ↗
21. Diagnosis of PEM fuel cells through current interruption10.1016/j.jpowsour.2007.06.072 ↗
22. Application of current switching method to estimate the model parameters of proton exchange membrane fuel cell10.1016/j.simpat.2009.09.008 ↗
23. Transient techniques for investigating mass-transport limitations in gas diffusion electrodes: I. Modeling the cathode10.1149/1.1624294 ↗
24. Transient techniques for investigating mass-transport limitations in gas diffusion electrodes: II. Experimental characterization of the PEFC cathode10.1149/1.1624295 ↗
25. Characterisation tools development for PEM electrolysers10.1016/j.ijhydene.2014.02.096 ↗
26. Characterisation of a PEM electrolyser using the current interrupt method10.1016/j.ijhydene.2014.09.153 ↗
27. In situ membrane resistance measurements in polymer electrolyte fuel cells by fast auxiliary current pulses10.1149/1.2044211 ↗
28. Measurement of ohmic voltage losses in individual cells of a PEMFC stack10.1016/S0378-7753(02)00391-9 ↗
29. Burger · 2017
30. Proton-conducting polymer membranes in fuel cells—humidification aspects10.1016/j.ssi.2003.01.001 ↗
31. Understanding electrical under-and overshoots in proton exchange membrane water electrolysis cells10.1149/2.0881914jes ↗
32. Fundamentals of PEM Water Electrolysis10.1201/b19096 ↗
33. Impact of intermittent operation on lifetime and performance of a PEM water electrolyzer10.1149/2.0421908jes ↗
34. Current challenges in catalyst development for PEM water electrolyzers10.1002/cite.201900101 ↗
35. Characterization Tools for Polymer Electrolyte Membrane (pem) Water Electrolyzers10.1201/b19096 ↗
36. Comparison of electrical energy efficiency of atmospheric and high-pressure electrolysers10.1016/j.ijhydene.2006.01.018 ↗