journal article·2021-04-01

A Potential Strategy for Simultaneous Determination of Deferoxamine and Vitamin C Using MCR-ALS with Nanostructured Electrochemical Sensor in Serum and Urine of Thalassemia and Diabetic Patients

Rozhin Darabi, Mehdi Shabani-Nooshabadi, Asma Khoobi

Publisher page

Abstract

Simultaneous determination of deferoxamine and vitamin C at the surface of a nanostructured -modified sensor is reported at this study. The electrode is designed based on a carbon paste electrode (CPE) modified with 1-ethyl-3-methylimidazolium chloride as an ionic liquid (IL) and CdO-nanoparticle/rGO (IL/CdO/rGO/CPE). The nanostructures are studied by various techniques containing X-ray diffraction (XRD), energy dispersive X-ray (EDX), field emission scanning electron microscopes (FESEM), cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS) and differential pulse voltammetry (DPV). The high degree of overlapping voltammograms is studied by multivariate curve resolution alternating least (MCR-ALS) algorithm. At first, a multivariate optimization is studied using response surface methodology (RSM) and central composite rotatable design (CCRD) model based on a five-level, three factor to optimize various parameters on DPV signal of the drugs. Then, second order data are built by changing in pulse heights of DPV. Results of MCR-ALS are used to data analysis that is obtained by electro-oxidation of deferoxamine and vitamin C. The strategy shows the current method is a potential way for analysis of the two important drugs in the presence of each other with high voltammetric overlapping in human serum and urine samples of patients with thalassemia major and minor. The voltammetric analyses of deferoxamine and vitamin C are performed in the concentration range of 5.0 × 10 −8 −900.0 × 10 −2 and 6.0 × 10 −8 −900.0 × 10 −2 M, and the detection limits are calculated 0.030 × 10 −6 and 0.025 × 10 −6 M, respectively.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Electrochemical Analysis and Applications · Electrochemical sensors and biosensors · Conducting polymers and applications

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (67)

Show source-provided references
1. A nanocellulose-based colorimetric assay kit for smartphone sensing of iron and iron-chelating deferoxamine drug in biofluids10.1016/j.aca.2019.08.056 ↗
2. Iron chelator Deferoxamine protects human neuroblastoma cell line SH-SY5Y from 6-Hydroxydopamine-induced apoptosis and autophagy dysfunction10.1016/j.jtemb.2019.126406 ↗
3. Role of vitamin C as an adjuvant therapy to different iron chelators in young β-thalassemia major patients: Efficacy and safety in relation to tissue iron overload10.1111/ejh.12594 ↗
4. Blood antioxidant status and urinary levels of catecholamine metabolites in β-thalassemia10.1080/10715769900300491 ↗
5. An impedimetric biosensor for DNA damage detection and study of the protective effect of deferoxamine against DNA damage10.1016/j.bioelechem.2018.03.012 ↗
6. The preventive role of deferoxamine against acute doxorubicin-induced cardiac, renal and hepatic toxicity in rats10.1006/phrs.2000.0769 ↗
7. Immunomodulatory and antimicrobial effects of vitamin C10.1556/1886.2019.00016 ↗
8. Awareness on thalasemia prevention and its treatment in community practice-a brief review
9. Product indiscriminate use of vitamin risks: A review10.1080/10408398.2019.1628003 ↗
10. The association of ascorbic acid, deferoxamine and N-acetylcysteine improves cardiac fibroblast viability and cellular function associated with tissue repair damaged by simulated ischemia/reperfusion10.3390/antiox8120614 ↗
11. Synergy between the iron chelator deferoxamine and the antimicrobial agents gentamicin, chloramphenicol, cefalothin, cefotiam and cefsulodin10.1007/BF02013900 ↗
12. Symposium : prooxidant effects of antioxidant vitamins (vitamin c-driven fre radical generation from iron)
13. Urinary iron excretion for evaluating iron chelation efficacy in children with thalassemia major10.1016/j.bcmd.2019.03.007 ↗
14. Is vitamin C supplementation in patients with β-thalassemia major beneficial or detrimental?10.1080/03630269.2016.1190373 ↗
15. Management of beta-thalassemia major using transfusions and iron chelation with deferoxamine10.1016/S0887-7963(88)70041-3 ↗
16. Determination of vitamin C from human urine and blood
17. Al-ayash · Determination of Desferrioxamine in the Drug Desferal TM as DFOM - Au (III) Complex by Using Indirect Electrothermal Atomic Absorption Spectrometry and Other Techniques · 2008 · 1-7
18. Ascorbic acid in human seminal plasma is protected from iron-mediated oxidation, but is potentially exposed to copper-induced damage10.1093/humrep/12.8.1699 ↗
19. A fast and validated chromatographic method for simultaneous determination of deferoxamine and D-penicillamine via chelate formation with metal ions in bulk and dosage forms10.4314/tjpr.v18i2.19 ↗
20. Iron and Alu- Liquid Chro-
21. Cramer · Department of · 1984 · 295 · 405
22. Differential pulse polarography procedure for the estimation of deferoxamine in pharmaceuticals
23. Voltammetric determination of uric acid at a fullerene-C 60-modified glassy carbon electrode10.1002/elan.200503353 ↗
24. ZnO/Ag/Mn2O3 nanocomposite for visible light-induced industrial textile effluent degradation, uric acid and ascorbic acid sensing and antimicrobial activity10.1039/C5RA02557E ↗
25. Micellar vs reversed phase liquid chromatography for the determination of desferrioxamine and its chelates with aluminium and iron in uremic serum10.1016/S0039-9140(97)00097-0 ↗
26. The determination of vitamin C in urine
27. Simultaneous determination of hydroxylamine, phenol and sulfite in water and waste water samples using a voltammetric nanosensor10.1016/S1452-3981(23)04994-5 ↗
28. ZnO/Ag nanocomposite: An efficient catalyst for degradation studies of textile effluents under visible light10.1016/j.msec.2013.01.046 ↗
29. Visible light induced degradation of methylene blue using CeO 2/V2O5 and CeO2/CuO catalysts10.1016/j.msec.2013.07.034 ↗
30. ZnO/Ag/CdO nanocomposite for visible light-induced photocatalytic degradation of industrial textile effluents10.1016/j.jcis.2015.04.035 ↗
31. The photocatalytic activity of ZnO prepared by simple thermal decomposition method at various temperatures10.1016/j.molliq.2012.10.018 ↗
32. A sensitive voltammetric sensor for determination of synthetic corticosteroid triamcinolone, abused for doping10.1016/j.bios.2009.05.016 ↗
33. Fullerene-C60-modified edge plane pyrolytic graphite electrode for the determination of dexamethasone in pharmaceutical formulations and human biological fluids10.1016/j.bios.2008.08.024 ↗
34. A novel copper (II) selective sensor based on Dimethyl 4, 4′ (o-phenylene) bis(3-thioallophanate) in PVC matrix10.1016/j.molliq.2012.07.016 ↗
35. Potential of activated carbon from waste rubber tire for the adsorption of phenolics: Effect of pre-treatment conditions10.1016/j.jcis.2013.11.067 ↗
36. Removal of arsenate from aqueous solution by electro-coagulation method using Al-Fe electrodes10.1016/S1452-3981(23)13848-X ↗
37. A novel electro analytical nanosensor based on graphene oxide/silver nanoparticles for simultaneous determination of quercetin and morin10.1016/j.electacta.2013.12.086 ↗
38. Determination of Acid Green 25 in the presence of Brilliant Blue in hair dye and wastewater using voltammetric sensor amplified with reduced graphene oxide/CoFe12O19-ionic liquid nanocomposite10.1016/j.eti.2020.101020 ↗
39. Optimization of bacteriocin production from Lactobacillus gasseri NBL 18 through response surface methodology10.20546/ijcmas.2019.803.238 ↗
40. Response surface methodology based optimization of air-film blade cooled gas turbine cycle for thermal performance prediction10.1016/j.applthermaleng.2019.114425 ↗
41. Application of Fe doped ZnO nanorods-based modified sensor for determination of sulfamethoxazole and sulfamethizole using chemometric methods in voltammetric studies10.1016/j.jelechem.2014.12.008 ↗
42. Monitoring the protective ability of thymoquinone mixture with p-cymene against bovine serum albumin (BSA) glycation: MCR-ALS analysis based on combined spectroscopic and electrochemical methods10.1016/j.ijbiomac.2017.10.135 ↗
43. Experimental and theoretical investigation of interaction between bovine serum albumin and the mixture of caffeic acid and salicylic acid as the antioxidants10.1016/j.electacta.2017.09.184 ↗
44. Optimization of ultrasonic-assisted extraction of pomegranate (Punica granatum L.) peel antioxidants by response surface methodology10.1016/j.seppur.2012.06.038 ↗
45. Chemometric studies of thymol binding with bovine serum albumin: A developing strategy for the successful investigation of pharmacological activity10.1016/j.bioelechem.2018.07.017 ↗
46. Subnanomolar determination of indium by adsorptive stripping differential pulse voltammetry using factorial design for optimization10.1080/00032710903061154 ↗
47. Removal of basic dye Auramine-O by ZnS:Cu nanoparticles loaded on activated carbon: Optimization of parameters using response surface methodology with central composite design10.1039/C4RA15637D ↗
48. A reversible fluorescence ‘off-on-off’ sensor for sequential detection of aluminum and acetate/fluoride ions10.1016/j.talanta.2015.05.053 ↗
49. Azo linked polycyclic aromatic hydrocarbons-based dual chemosensor for Cu2 + and Hg2 + ions10.1021/acs.iecr.5b00775 ↗
50. Modeling of competitive ultrasonic assisted removal of the dyes - Methylene blue and Safranin-O using Fe3O4 nanoparticles10.1016/j.cej.2014.12.090 ↗
51. The effect of carbonaceous materials on faradaic and charging current contribution in carbon paste electrodes investigated by chemometrics methods10.1007/s10008-019-04422-2 ↗
52. Reversible high capacity and reaction mechanism of Cr2(NCN)3 negative electrodes for li-ion batteries10.1002/ente.201901260 ↗
53. Optimization of enzyme-assisted extraction of ferulic acid from sweet corn cob by response surface methodology10.1002/jsfa.10155 ↗
54. Encapsulation of live marine bacteria for use in aquaculture facilities and process evaluation using response surface methodology10.1007/s00253-019-10332-0 ↗
55. Improved adsorption performance of rubber-based hydrogel: optimisation through response surface methodology, isotherm, and kinetic studies10.1007/s10971-020-05254-7 ↗
56. On the performance of multivariate curve resolution to resolve highly complex liquid chromatography–full scan mass spectrometry data for quantification of selected immunosuppressants in blood and water samples10.1016/j.microc.2019.104298 ↗
57. A novel fluorimetric method for glyphosate and AMPA determination with NBD-Cl and MCR-ALS10.1016/j.saa.2019.01.078 ↗
58. Application of multivariate curve resolution alternating least squares to biomedical analysis using electrochemical techniques at a nanostructure-based modified sensor10.1016/j.electacta.2014.03.016 ↗
59. Chemometrics-assisted determination of Sudan dyes using zinc oxide nanoparticle-based electrochemical sensor10.1016/j.foodchem.2018.12.132 ↗
60. Modification of carbon paste electrode with NiO/graphene oxide nanocomposite and ionic liquids for fabrication of high sensitive voltammetric sensor on sulfamethoxazole analysis10.1016/j.molliq.2016.05.001 ↗
61. Synthesis of graphene oxide using modified hummers method: solvent influence10.1016/j.proeng.2017.04.118 ↗
62. Optimization of the electro-Fenton and solar photoelectro-Fenton treatments of sulfanilic acid solutions using a pre-pilot flow plant by response surface methodology10.1016/j.jhazmat.2012.04.053 ↗
63. Screening and production of a potential extracellular fungal laccase from Penicillium chrysogenum: Media optimization by response surface methodology (RSM)and central composite rotatable design (CCRD)10.1016/j.btre.2019.e00344 ↗
64. Optimization of diesel engine performance and emission parameters employing cassia tora methyl esters-response surface methodology approach10.1016/j.energy.2018.12.013 ↗
65. Applications of electrochemical data analysis by multivariate curve resolution-alternating least squares10.1016/j.trac.2017.01.005 ↗
66. Multidimensional voltammetry: Four-way multivariate calibration with third-order differential pulse voltammetric data for multi-analyte quantification in the presence of uncalibrated interferences10.1016/j.chemolab.2015.09.003 ↗
67. Maier · Fundamentals and Applications Plasmonics : Fundamentals and Applications. · 2004 · 22710.1007/0-387-37825-1 ↗