journal article·2001-12

Nonlinear transient analysis of reinforced concrete slabs subjected to blast loading and retrofitted with CFRP composites

Khalid M. Mosalam, Ayman S. Mosallam

Composites Part B: Engineering· Volume 32· Issue 8
Publisher page

Abstract

Abstract Computational models using the finite element method for nonlinear transient analysis of reinforced concrete (RC) two-way slabs subjected to blast loading are presented. Both as-built and retrofitted slabs with carbon fiber reinforced polymer (CFRP) composite strips are analyzed. The models are used to investigate different parameters including (a) loading duration, and (b) effect of CFRP retrofit on damage accumulation. In this study, damage is globally quantified by the amount of reduction of the first two vibrational frequencies of the slabs. Local representation of damage in terms of reinforcing steel strains is also discussed. The computational models for both the as-built and the retrofitted slabs are verified using experimental results. In these experiments, a slowly increasing uniform pressure is applied to the bottom surface of large-scale RC slab specimens using high-pressure water bag. Experimental results showed that an increase up to 200% in the load carrying capacity is achieved when using the CFRP composite retrofit system. Transient nonlinear analysis results proved the efficiency of the CFRP composite retrofit in improving the slab behavior under blast loading for different loading durations, i.e. for small, medium, and large charge weights at the same applied maximum pressure. In particular, less than 50% reduction of the fundamental frequency due to concrete damage is obtained for the retrofitted slab compared to more than 85% reduction for the as-built slab. Moreover, the maximum displacement is reduced by 40–70% with the CFRP retrofit compared to the as-built slab. As for reinforcing steel strains, the application of CFRP retrofit significantly limited the spread of yielding in time and space. The improved slab behavior with CFRP is best when retrofitting is applied to both sides of the slab.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Structural Response to Dynamic Loads · Structural Behavior of Reinforced Concrete · Structural Analysis of Composite Materials

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (15)

Show source-provided references
1. ACI Committee 440. State of the art report on fiber reinforced plastic reinforcement for concrete structures, ACI 440R-96, 1996, 68 p.
2. CEB-FIP Model Code 1990. Comité Euro-International du Béton, 1993.
3. Chopra · 1995
4. DIANA Finite Element Analysis User's Manual Release 7.2, Third ed, TNO Building and Construction Research, The Netherlands, 1999.
5. DTRA/TSWG Program. Blast mitigation for structures, Status Report, Commission on Engineering and Technical Systems, National Research Council, National Academy Press, Washington, DC, USA, 1999.
6. Fenestra PH. Computational aspects of biaxial stress in plain and reinforced concrete. PhD Dissertation, Delft University of Technology, Delft, The Netherlands, 1993.
7. Improved numerical dissipation for time integration algorithms in structural dynamics10.1002/eqe.4290050306 ↗
8. International Conference of Building Officials Evaluation Service. Acceptance criteria for concrete and reinforced and unreinforced masonry strengthening using fiber reinforced composite systems (AC125), ICBO-ES, Whittier, CA, USA, 1998.
9. Repair and rehabilitation of reinforced and unreinforced concrete slabs with polymer composites
10. 2000
11. Concrete under impact loading: tensile strength and bond
12. Ross · 1991 · 577
13. Rots JG. Computational modeling of concrete fracture. PhD Dissertation, Delft University of Technology, Delft, The Netherlands, 1988.
14. Tedesco · 1999
15. The generalized differential quadrature rule for fourth-order differential equations10.1002/nme.102 ↗