journal article·2024-03-01

Material Selection for Artificial Femur Bone Using PROMETHEE-GAIA Method

Muhammed Tayyip Koçak, Mehmet Said Bayraklılar, Melih Kuncan

Journal of Testing and Evaluation· Volume 52· Issue 2
Publisher page

Abstract

ABSTRACT When replacing bones and implants, choosing the right materials for the artificial bone and orthopedic implants is crucial to the procedure’s success. In this work, a thorough assessment of the literature was followed by a thorough and rigorous evaluation of prospective materials for prosthetic femurs using a multicriteria decision-making process known as PROMETHEE-GAIA (Preference Ranking Organization METHod for Enrichment Evaluation and Geometric Analysis for Interactive Assistance). The proposed approach was validated using a total of 12 assessment parameters, including density, tensile strength, and ultimate tensile strength, and 17 candidate materials. The significance of the chosen criteria is well described. These 17 candidate implant materials and the 12 assessment criteria were used to develop a choice matrix. Rankings over the prepared matrix were produced using the PROMETHEE-GAIA program. Ti-6Al-7Nb, Ti-6Al-4V, and ASTM F1537, Standard Specification for Wrought Cobalt-28Chromium-6Molybdenum Alloys for Surgical Implants (UNS R31537, UNS R31538, and UNS R31539), Co-Cr-W emerged as the top contenders and were demonstrated as possible materials for effective artificial femur materials because of the assessment. With a large number of pertinent criteria and a wide range of materials, this study offers a framework for the selection of implant materials. It also emphasizes how choosing materials carefully may increase the durability and efficiency of orthopedic implants.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Titanium Alloys Microstructure and Properties · Orthopaedic implants and arthroplasty · Bone Tissue Engineering Materials

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Electrical and Electronics Engineering, Siirt University 1 , Mühendislik-Mimarlik Fakültesi A Blok, Kezer Yerleskesi, Siirt 56100 ,

Department of Software Engineering, Istanbul Health and Technology University 2 , Istanbul 34000 ,

Department of Civil Engineering Siirt University 3 , Siirt, 56100 ,

Department of Electrical and Electronics Engineering, Siirt University 4 , Kezer Kampüsü, Siirt, 56100 ,

References (64)

Show source-provided references
1. To Study the Total Duration of Union Following Pfixationi with Titanium Elastic Nail10.33545/orthor.2019.v3.i3a.155 ↗
2. A Comparative Study on Neck Shaft Angle and Length Femur in South Gujarat10.16965/ijar.2019.268 ↗
3. Neck Shaft Angle of Non-articulated Femur Bones among Adults in Nepal10.3126/mjsbh.v14i2.13713 ↗
4. Age-Dependent Cortical Bone Loss in a Medieval Population10.1002/(SICI)1099-1212(199603)6:2<144::AID-OA261>3.0.CO;2-G ↗
5. Tissue-Sparing Surgery: 25 Years’ Experience with Femoral Neck Preserving Hip Arthroplasty10.1007/s10195-006-0120-2 ↗
6. Biomechanical Measurements of Surgical Drilling Force and Torque in Human versus Artificial Femurs10.1115/1.4007953 ↗
7. Microstructural Failure Mechanisms in the Human Proximal Femur for Sideways Fall Loading10.1002/jbmr.2033 ↗
8. Cancellous Bone Screw Purchase: A Comparison of Synthetic Femurs, Human Femurs, and Finite Element Analysis10.1243/09544119JEIM409 ↗
9. The Biomechanical Effect of Changes in Cancellous Bone Density on Synthetic Femur Behaviour10.1177/0954411911420004 ↗
10. Cortical Screw Pullout Strength and Effective Shear Stress in Synthetic Third Generation Composite Femurs10.1115/1.2540926 ↗
11. Stress Analysis of Concrete Materials Based on Finite Element Analysis10.1155/2022/1826598 ↗
12. Inner Design of Artificial Test Bones for Biomechanical Investigations Using Topology Optimization10.1007/s40964-022-00343-1 ↗
13. Development of New Metallic Alloys for Biomedical Applications10.1016/j.actbio.2012.06.037 ↗
14. Ceramic Materials for Biomedical Applications: An Overview on Properties and Fabrication Processes10.3390/jfb14030146 ↗
15. Application of MCDM Method in Material Selection for Optimal Design: A Review10.1016/j.rinma.2020.100115 ↗
16. Material Selection for Turbine Seal Strips Using Promethee-Gaia Method10.1016/j.matpr.2018.06.069 ↗
17. Density, Specific Gravity, and Api Gravity
18. Tensile Strength Measurement for Foundry Sand Brick10.31033/ijemr.8.4.3 ↗
19. Determination of Poisson’s Ratio of Rock Material by Changing Axial Stress and Unloading Lateral Stress Test10.1007/s00603-014-0586-9 ↗
20. 2016
21. Specific Heat Capacity of Wood10.5552/drind.2014.1333 ↗
22. Thermal Conductivity of Solids10.1063/1.3037419 ↗
23. Melting Point Determination from Solid−Liquid Coexistence Initiated by Surface Melting10.1021/jp070242m ↗
24. On the Mechanisms of Biocompatibility10.1016/j.biomaterials.2008.04.023 ↗
25. Corrosion Resistance through the Application of Anti-corrosion Coatings
26. Microalgal Species Selection for Biodiesel Production Based on Fuel Properties Derived from Fatty Acid Profiles10.3390/en6115676 ↗
27. Analysis of Heavy Metals in Road-Deposited Sediments10.1016/j.aca.2006.04.064 ↗
28. A Multi-criteria Analysis Approach for Ranking and Selection of Microorganisms for the Production of Oils for Biodiesel Production10.1016/j.biortech.2015.04.083 ↗
29. Spatial Distribution, Accumulation and Human Health Risk Assessment of Heavy Metals in Soil and Groundwater of the Tano Basin, Ghana10.1016/j.ecoenv.2018.09.015 ↗
30. Optimal Material Selection Study of Prosthetic Socket and Pylon Tube in Transtibial Prosthesis Fabrication10.1088/2631-8695/ac0094 ↗
31. Multiple-Criteria Decision-Making and Sensitivity Analysis for Selection of Materials for Knee Implant Femoral Component10.3390/ma14082084 ↗
32. Multicriteria Decision Analysis in Improving Quality of Design in Femoral Component of Knee Prostheses: Influence of Interface Geometry and Material10.1155/2015/693469 ↗
33. An Approach for Material Selection for Bone Staple (an Orthopaedic Implant) Using Gra and Fuzzy Logic10.1016/j.matpr.2020.11.331 ↗
34. Biomedical Applications of Titanium and Its Alloys10.24874/PES03.01.005 ↗
35. In Vitro Analyses of the Toxicity, Immunological, and Gene Expression Effects of Cobalt-Chromium Alloy Wear Debris and Co Ions Derived from Metal-on-Metal Hip Implants10.3390/lubricants3030539 ↗
36. A Review on Surface Treatment of Stainless Steel Orthopedic Implants
37. Influences of Passivating Elements on the Corrosion and Biocompatibility of Super Stainless Steels10.1002/jbm.b.31018 ↗
38. Ceramics for Medical Applications: A Picture for the Next 20 Years10.1016/j.jeurceramsoc.2008.08.025 ↗
39. Total Hip Arthroplasty: Past, Present, and Future. What Has Been Achieved?10.5371/hp.2019.31.4.179 ↗
40. Use of Carbon-Fiber-Reinforced Composite Implants in Orthopedic Surgery10.3928/01477447-20141124-05 ↗
41. The Use of Composite Materials in Modern Orthopaedic Medicine and Prosthetic Devices: A Review10.1016/j.compscitech.2011.08.017 ↗
42. Magnesium Alloys as Implant Materials—Principles of Property Design for Mg-RE Alloys10.1016/j.actbio.2009.09.010 ↗
43. Biodegradable Magnesium Alloys as Temporary Orthopaedic Implants: A Review10.1007/s10534-019-00170-y ↗
44. Biocompatibility Issues with Modern Implants in Bone - A Review for Clinical Orthopedics10.2174/1874325000802010066 ↗
45. Short-Term and Long-Term Effects of Orthopedic Biodegradable Implants10.1615/JLongTermEffMedImplants.v21.i2.10 ↗
46. Numerical Analysis of Fractured Femur Bone with Prosthetic Bone Plates10.1016/j.proeng.2013.09.204 ↗
47. Corrosion Behaviour of Nitrogen Implanted Titanium in Simulated Body Fluid10.1179/000705900101501308 ↗
48. The Corrosion Behaviour of Ti–6Al–4V, Ti–6aAl–7Nb and Ti–13Nb–13Zr in Protein Solutions10.1016/S0142-9612(98)00217-8 ↗
49. Corrosion Resistance of Ti-6Al-4V and ASTM F75 Alloys Processed by Electron Beam Melting10.1016/j.jmrt.2017.05.003 ↗
50. Biomaterials for Hip Implants – Important Considerations Relating to the Choice of Materials10.1515/bams-2017-0017 ↗
51. Materials Design for Bone-Tissue Engineering10.1038/s41578-020-0204-2 ↗
52. MatWeb, “Online Materials Information Resource- MatWeb,” MatWeb, 1996, https://matweb.com/index.aspx
53. Iron Boar Labs Ltd., “MakeItFrom.com: Material Properties Database,” MakeItFrom, https://www.makeitfrom.com/
54. Bone Density and Primary Stability in Implant Therapy10.1111/j.1600-0501.2006.01356.x ↗
55. Influence of Implant Design and Bone Quality on Stress/Strain Distribution in Bone around Implants: A 3-Dimensional Finite Element Analysis
56. A Double-Blind Randomized Controlled Trial (RCT) of Titanium-13Zirconium versus Titanium Grade IV Small-Diameter Bone Level Implants in Edentulous Mandibles—Results from a 1-Year Observation Period10.1111/j.1708-8208.2010.00324.x ↗
57. Biomechanical Optimization of Elastic Modulus Distribution in Porous Femoral Stem for Artificial Hip Joints10.1007/s42235-018-0057-1 ↗
58. On the Specific Heat Capacity of CuO Nanofluid10.1155/2010/172085 ↗
59. Study on Thermophysical Properties of a Lead–Bismuth-Based Graphene Nanofluid10.3389/fenrg.2021.727447 ↗
60. Graphene Oxide and Graphene Reinforced PMMA Bone Cements: Evaluation of Thermal Properties and Biocompatibility10.3390/ma12193146 ↗
61. Optimal Material Selection for Total Hip Implant: A Finite Element Case Study10.1007/s13369-019-04088-y ↗
62. The Biocompatibility of Implant Materials10.1016/B978-0-12-800196-7.00003-7 ↗
63. Corrosion of Metallic Biomaterials: A Review10.3390/ma12030407 ↗
64. B. Mareschal, “Visual PROMETHEE Download,” Informer Technologies, 2023, https://visual-promethee.software.informer.com/download/