Measurements of the Limit of Detection for Electrochemical Gas Sensors
Source abstract
Abstract
ABSTRACT Electrochemical amperometric gas cells are becoming the sensor of choice when measuring polluting gases using low-cost air quality networks. A number of technical issues remain to be resolved to deliver fit-for-purpose monitoring systems: humidity corrections are needed but not well understood, interfering gases such as ozone can have variable cross-sensitivity and calibration intervals, and procedures are still being investigated. Another unanswered question is the limit of detection (LOD) for electrochemical gas sensors. Estimates range from hundreds of equivalent parts per billion (ppbv) to single-digit ppbv concentrations. We discuss the LOD for nitrogen dioxide (NO2), an important gas when monitoring air quality. Multiple NO2 sensor systems were tested in an environmental chamber to determine, among other parameters, the LOD for NO2 electrochemical gas sensors. Low-noise electronics and battery powering further reduced electronic noise, allowing the intrinsic LOD of the electrochemical cell to be determined. Noise, quantified as the standard deviation in zero air in a very stable temperature and relative humidity–controlled chamber was <500 pA, which translated into 1.6 ppbv, so the LOD, 3 × standard deviation, was 4.8 ppb. Interestingly, the LOD calculated with 300 ppbv NO2 test gas was the same (±0.1 ppbv). Further tests with a higher resolution analog-to-digital converter resulted in the same LOD, further leading to the conclusion that for the Alphasense NO2-A43F NO2 sensor, the limiting value for LOD is 4.8 ppbv.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Air Quality Monitoring and Forecasting · Gas Sensing Nanomaterials and Sensors · Advanced Chemical Sensor Technologies
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
NosmoTech Ltd. 1 , 11 The Crescent, Cambridge CB3 0AZ ,
Air Quality and Aerosol Metrology Group, National Physical Laboratory 2 , Hampton Rd., Teddington TW11 0LW ,
References (21)
Show source-provided references
1. Estimates and 25-Year Trends of the Global Burden of Disease Attributable to Ambient Air Pollution: An Analysis of Data from the Global Burden of Diseases Study 201510.1016/S0140-6736(17)30505-6 ↗
2. 2021
3. Air Quality Status and Trends over Large Cities in South America10.1016/j.envsci.2020.09.009 ↗
4. AQMesh, “AQMesh Tracks Pollution Hot-Spots,” AQMesh, 2016. https://www.aqmesh.com/news/aqmesh-tracks-pollution-hot-spots/
5. National Archives and Records Administration, “Code of Federal Regulations (CFR) Title 40, Chapter I, Subchapter C, Part 50,” National Archives and Records Administration, 2023, https://www.ecfr.gov/
6. World Health Organization · 2021
7. Considerations of Thermodynamics and Kinetics for the Effects of Relative Humidity on the Electrolyte in Electrochemical Toxic Gas Sensors10.1021/acssensors.1c01339 ↗
8. Field Calibration of Electrochemical NO2 Sensors in a Citizen Science Context10.5194/amt-11-1297-2018 ↗
9. Low-Cost Outdoor Air Quality Monitoring and Sensor Calibration: A Survey and Critical Analysis10.1145/3446005 ↗
10. Field Comparison of Electrochemical Gas Sensor Data Correction Algorithms for Ambient Air Measurements10.1016/j.snb.2020.128897 ↗
11. The Use of Electrochemical Sensors for Monitoring Urban Air Quality in Low-Cost, High-Density Networks10.1016/j.atmosenv.2012.11.060 ↗
12. 2014
13. Development of Air Quality Boxes Based on Low-Cost Sensor Technology for Ambient Air Quality Monitoring10.3390/s22103830 ↗
14. Understanding and Correcting Unwanted Influences on the Signal from Electrochemical Gas Sensors10.1021/acssensors.0c02589 ↗
15. Amperometric Gas Sensors as a Low Cost Emerging Technology Platform for Air Quality Monitoring Applications: A Review10.1021/acssensors.7b00620 ↗
16. An Improved Low-Power Measurement of Ambient NO2 and O3 Combining Electrochemical Sensor Clusters and Machine Learning10.5194/amt-12-1325-2019 ↗
17. Performance Evaluation of Amperometric Sensors for the Monitoring of O3 and NO2 in Ambient Air at ppb Level10.1016/j.proeng.2015.08.676 ↗
18. Evaluation of Low-Cost Electro-chemical Sensors for Environmental Monitoring of Ozone, Nitrogen Dioxide, and Carbon Monoxide10.1080/15459624.2017.1388918 ↗
19. Differentiating NO2 and O3 at Low Cost Air Quality Amperometric Gas Sensors10.1021/acssensors.6b00603 ↗
20. Breathe London Pilot, “Our Project,” Breathe London Pilot, 2023, https://breathelondonpilot.org/
21. Alphasense Limited · 2013