journal article·2018-07

The key role of 3-glycidoxypropyltrimethoxysilane sol–gel precursor in the development of wearable sensors for health monitoring

Valentina Trovato, Claudio Colleoni, Angela Castellano, Maria Rosaria Plutino

Publisher page

Abstract

Textiles represent an attractive class of materials for realizing wearable biosensors. Electronic textiles, or smart textiles, describe the convergence of electronics and textiles into fabrics, which are able to sense, compute, communicate, and actuate. As many different electronic systems can be connected to any clothing, a wearable system becomes more versatile, and the user can change its look depending on environmental changes and individual preference. In this review, we want to explain how it is possible to develop the sensing component of a wearable sensor by sol-gel method based on the use of opportune organofunctional trialkoxysilane precursors, such as 3-glycidoxypropyltrimethoxysilane. Results show that the halochromic dyestuffs are completely entrapped in the sol-gel coatings, both through chemical and physical interactions with the textile fabric. Moreover, a certain washing fastness was observed. Sensor films show excellent reproducibility, reversibility, and short response times, with dynamic ranges from pH 4.4-6.0 (Methyl Red), pH 6.0-7.0 (Nitrazine Yellow), and pH 4.5-8.3 (Litmus), respectively. [Figure not available: see fulltext.].
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Advanced Sensor and Energy Harvesting Materials · Conducting polymers and applications · Analytical Chemistry and Sensors

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (88)

Show source-provided references
1. Lobnik A, Turel M, Korent SU (2012) Optical chemical sensors: design and applications. In: Wang W (ed) Advances in chemical sensors. IntechOpen Limited, UK, pp 3–28
2. Lobnik A (2012) Wearable optical chemical sensors. In: Kiekens P, Jayaraman S (eds) Intelligent textiles and clothing for ballistic and NBC protection. NATO Science for Peace and Security Series B: Physics and Biophysics. Springer, Dordrecht, p 29–52
3. Stoppa M, Chiolerio A (2014) Wearable electronics and smart textiles: a critical review. Sensors 14:11957–11992. https://doi.org/10.3390/s14071195710.3390/s140711957 ↗
4. Diamond D, Coyle S, Scarmagnani S, Hayes J (2008) Wireless Sensor networks and chemo-/biosensing. Chem Rev 108:652–679. https://doi.org/10.1021/cr068118710.1021/cr0681187 ↗
5. Diamond D, Lau KT, Brady S, Cleary J (2008) Integration of analytical measurements and wireless communications - current issues and future strategies. Talanta 75:606–612. https://doi.org/10.1016/j.talanta.2007.11.02210.1016/j.talanta.2007.11.022 ↗
6. Farré M, Kantiani L, Pérez S et al. (2009) Sensors and biosensors in support of EU Directives. TrAC Trends Anal Chem 28:170–185. https://doi.org/10.1016/j.trac.2008.09.01810.1016/j.trac.2008.09.018 ↗
7. Kotanen CN, Moussy FG, Carrara S, Guiseppi-Elie A (2012) Implantable enzyme amperometric biosensors. Biosens Bioelectron 35:14–26. https://doi.org/10.1016/j.bios.2012.03.01610.1016/j.bios.2012.03.016 ↗
8. Yang Y-L, Chuang M-C, Lou S-L, Wang J (2010) Thick-film textile-based amperometric sensors and biosensors. Analyst 135:1230. https://doi.org/10.1039/b926339j10.1039/b926339j ↗
9. Williamson ED, Savage VL, Lingard B et al. (2007) A biocompatible microdevice for core body temperature monitoring in the early diagnosis of infectious disease. Biomed Microdevices 9:51–60. https://doi.org/10.1007/s10544-006-9007-510.1007/s10544-006-9007-5 ↗
10. Pinna GD, Maestri R, Mortara A et al. (2010) Long-term time-course of nocturnal breathing disorders in heart failure patients. Eur Respir J 35:361–367. https://doi.org/10.1183/09031936.0006670910.1183/09031936.00066709 ↗
11. Massagram W, Hafner N, Chen M et al. (2010) Digital heart-rate variability parameter monitoring and assessment ASIC. IEEE Trans Biomed Circuits Syst 4:19–26. https://doi.org/10.1109/TBCAS.2009.203555510.1109/TBCAS.2009.2035555 ↗
12. NA (2000) Wireless capsule endoscopy. Nature 405:417–419. https://doi.org/10.1038/3501314010.1038/35013140 ↗
13. Ledet EH, D’Lima D, Westerhoff P et al. (2012) Implantable sensor technology: from research to clinical practice. J Am Acad Orthop Surg 20:383–392. https://doi.org/10.5435/JAAOS-20-06-38310.5435/JAAOS-20-06-383 ↗
14. Deng Z-S, Liu J (2008) Effect of fixing material on skin-contact temperature measurement by wearable sensor. In: 2008 5th international summer school and symposium on medical devices and biosensors. IEEE, p 137–140. https://doi.org/10.1109/ISSMDBS.2008.457503710.1109/ISSMDBS.2008.4575037 ↗
15. Fu X, Chen W, Ye S et al. (2011) A wireless implantable sensor network system for in vivo monitoring of physiological signals. IEEE Trans Inf Technol Biomed 15:577–584. https://doi.org/10.1109/TITB.2011.214953610.1109/TITB.2011.2149536 ↗
16. Troster G (2005) The agenda of wearable healthcare. In: IMIA yearbook of medical informatics. Stuttgart, Germany, Schattauer, pp 125–13810.1055/s-0038-1638446 ↗
17. Lam Po Tang S, Stylios GK (2006) An overview of smart technologies for clothing design and engineering. Int J Cloth Sci Technol 18:108–128. https://doi.org/10.1108/0955622061064576610.1108/09556220610645766 ↗
18. Chiang CK, Fincher CR, Park YW et al. (1977) Electrical conductivity in doped polyacetylene. Phys Rev Lett 39:1098–1101. https://doi.org/10.1103/PhysRevLett.39.109810.1103/PhysRevLett.39.1098 ↗
19. Guimard NKE, Sessler JL, Schmidt CE (2009) Toward a biocompatible and biodegradable copolymer incorporating electroactive oligothiophene units. Macromolecules 42:502–511. https://doi.org/10.1021/ma801985910.1021/ma8019859 ↗
20. Carpi F, De Rossi D (2005) Electroactive polymer-based devices for e-textiles in biomedicine. IEEE Trans Inf Technol Biomed 9:295–318. https://doi.org/10.1109/TITB.2005.85451410.1109/TITB.2005.854514 ↗
21. Maccioni M, Orgiu E, Cosseddu P et al. (2006) Towards the textile transistor: Assembly and characterization of an organic field effect transistor with a cylindrical geometry. Appl Phys Lett 89:143515. https://doi.org/10.1063/1.235703010.1063/1.2357030 ↗
22. Rosace G, Trovato V, Colleoni C et al. (2017) Structural and morphological characterizations of MWCNTs hybrid coating onto cotton fabric as potential humidity and temperature wearable sensor. Sens Actuators B Chem 252:428–439. https://doi.org/10.1016/j.snb.2017.05.17510.1016/j.snb.2017.05.175 ↗
23. Wong YWH, Yuen CWM, Leung MYS et al. (2006) Selected applications of nanotechnology in textiles. AUTEX Res J 6:1–810.1515/aut-2006-060101 ↗
24. Brinker CJ, Scherrer GW (1990) Sol-gel science: the physics and chemistry of sol-gel processing. Academic Press Inc., Boston
25. Lin J (2000) Recent development and applications of optical and fiber-optic pH sensors. TrAC Trends Anal Chem 19:541–552. https://doi.org/10.1016/S0165-9936(00)00034-010.1016/S0165-9936(00)00034-0 ↗
26. Tsai P-J, McIntosh J, Pearce P et al. (2002) Anthocyanin and antioxidant capacity in Roselle (Hibiscus Sabdariffa L.) extract. Food Res Int 35:351–356. https://doi.org/10.1016/S0963-9969(01)00129-610.1016/S0963-9969(01)00129-6 ↗
27. Maciel VBV, Yoshida CMP, Franco TT (2012) Development of a prototype of a colourimetric temperature indicator for monitoring food quality. J Food Eng 111:21–27. https://doi.org/10.1016/j.jfoodeng.2012.01.03710.1016/j.jfoodeng.2012.01.037 ↗
28. Van der Schueren L, De Clerck K (2010) The use of pH-indicator dyes for pH-sensitive textile materials. Text Res J 80:590–603. https://doi.org/10.1177/004051750934644310.1177/0040517509346443 ↗
29. Schmid-Wendtner M-H, Korting HC (2006) The pH of the skin surface and its impact on the barrier function. Skin Pharmacol Physiol 19:296–302. https://doi.org/10.1159/00009467010.1159/000094670 ↗
30. Curto VF, Coyle S, Byrne R et al. (2012) Concept and development of an autonomous wearable micro-fluidic platform for real time pH sweat analysis. Sens Actuators B Chem 175:263–270. https://doi.org/10.1016/j.snb.2012.02.01010.1016/j.snb.2012.02.010 ↗
31. Patterson MJ, Galloway SD, Nimmo MA (2000) Variations in regional sweat composition in normal human males. Exp Physiol 85:869–875. https://doi.org/10.1111/j.1469-445X.2000.02058.x10.1111/j.1469-445X.2000.02058.x ↗
32. Morgan RM, Patterson MJ, Nimmo MA (2004) Acute effects of dehydration on sweat composition in men during prolonged exercise in the heat. Acta Physiol Scand 182:37–43. https://doi.org/10.1111/j.1365-201X.2004.01305.x10.1111/j.1365-201X.2004.01305.x ↗
33. Robinson KL, Lawrence NS (2006) Redox-sensitive copolymer: a single-component pH sensor. Anal Chem 78:2450–2455. https://doi.org/10.1021/ac051787k10.1021/ac051787k ↗
34. Wencel D, Abel T, McDonagh C (2014) Optical chemical pH sensors. Anal Chem 86:15–29. https://doi.org/10.1021/ac403516810.1021/ac4035168 ↗
35. Seitz WR, Sepaniak MJ (1988) Chemical sensors based on immobilized indicators and fiber optics. C R C Crit Rev Anal Chem 19:135–173. https://doi.org/10.1080/1040834880854281010.1080/10408348808542810 ↗
36. Van der Schueren L, de Clerck K (2012) Halochromic textile materials as innovative pH-sensors. Adv Sci Technol 80:47–52. https://doi.org/10.4028/www.scientific.net/AST.80.4710.4028/www.scientific.net/AST.80.47 ↗
37. Ismail WNW (2016) Sol–gel technology for innovative fabric finishing—a review. J Sol-Gel Sci Technol 78:698–707. https://doi.org/10.1007/s10971-016-4027-y10.1007/s10971-016-4027-y ↗
38. Mahltig B, Haufe H, Böttcher H (2005) Functionalisation of textiles by inorganic sol–gel coatings. J Mater Chem 15:4385. https://doi.org/10.1039/b505177k10.1039/b505177k ↗
39. Camlibel NO, Arik B (2017) Sol-gel applications in textile finishing processes. In: Chandra U (ed) Recent applications in sol-gel synthesis. IntechOpen Limited, UK, pp 253–281
40. Štular D, Simončič B, Tomšič B (2017) Stimuli-responsive hydrogels for textile functionalisation: a review. Tekstilec 60:76–96. https://doi.org/10.14502/Tekstilec2017.60.76-9610.14502/Tekstilec2017.60.76-96 ↗
41. Abidi N, Hequet E, Tarimala S, Dai LL (2007) Cotton fabric surface modification for improved UV radiation protection using sol–gel process. J Appl Polym Sci 104:111–117. https://doi.org/10.1002/app.2457210.1002/app.24572 ↗
42. Mahltig B, Textor T (2006) Combination of silica sol and dyes on textiles. J Sol-Gel Sci Technol 39:111–118. https://doi.org/10.1007/s10971-006-7744-910.1007/s10971-006-7744-9 ↗
43. Mahltig B, Fiedler D, Böttcher H (2004) Antimicrobial sol-gel coatings. J Sol-Gel Sci Technol 32:219–222. https://doi.org/10.1007/s10971-004-5791-710.1007/s10971-004-5791-7 ↗
44. Poli R, Colleoni C, Calvimontes A et al. (2015) Innovative sol–gel route in neutral hydroalcoholic condition to obtain antibacterial cotton finishing by zinc precursor. J Sol-Gel Sci Technol 74:151–160. https://doi.org/10.1007/s10971-014-3589-910.1007/s10971-014-3589-9 ↗
45. Colleoni C, Guido E, Migani V, Rosace G (2015) Hydrophobic behaviour of non-fluorinated sol–gel based cotton and polyester fabric coatings. J Ind Text 44:815–834. https://doi.org/10.1177/152808371351666410.1177/1528083713516664 ↗
46. Colleoni C, Esposito F, Guido E et al. (2017) Ceramic coatings for water-repellent textiles. IOP Conf Ser Mater Sci Eng 254:122002. https://doi.org/10.1088/1757-899X/254/12/12200210.1088/1757-899X/254/12/122002 ↗
47. Mahltig B, Textor T (2008) Nanosols and textiles. World Scientific Publishing Co. Pte. Ltd, Singapore10.1142/6961 ↗
48. Alongi J, Colleoni C, Malucelli G, Rosace G (2012) Hybrid phosphorus-doped silica architectures derived from a multistep sol–gel process for improving thermal stability and flame retardancy of cotton fabrics. Polym Degrad Stab 97:1334–1344. https://doi.org/10.1016/j.polymdegradstab.2012.05.03010.1016/j.polymdegradstab.2012.05.030 ↗
49. Vasiljević J, Hadžić S, Jerman I et al. (2013) Study of flame-retardant finishing of cellulose fibres: Organic–inorganic hybrid versus conventional organophosphonate. Polym Degrad Stab 98:2602–2608. https://doi.org/10.1016/j.polymdegradstab.2013.09.02010.1016/j.polymdegradstab.2013.09.020 ↗
50. Kappes RS, Urbainczyk T, Artz U et al. (2016) Flame retardants based on amino silanes and phenylphosphonic acid. Polym Degrad Stab 129:168–179. https://doi.org/10.1016/j.polymdegradstab.2016.04.01210.1016/j.polymdegradstab.2016.04.012 ↗
51. Guido E, Alongi J, Colleoni C et al. (2013) Thermal stability and flame retardancy of polyester fabrics sol–gel treated in the presence of boehmite nanoparticles. Polym Degrad Stab 98:1609–1616. https://doi.org/10.1016/j.polymdegradstab.2013.06.02110.1016/j.polymdegradstab.2013.06.021 ↗
52. Grancaric AM, Colleoni C, Guido E et al. (2017) Thermal behaviour and flame retardancy of monoethanolamine-doped sol-gel coatings of cotton fabric. Prog Org Coat 103:174–181. https://doi.org/10.1016/j.porgcoat.2016.10.03510.1016/j.porgcoat.2016.10.035 ↗
53. Colleoni C, Massafra MR, Rosace G (2012) Photocatalytic properties and optical characterization of cotton fabric coated via sol–gel with non‐crystalline TiO2 modified with poly(ethylene glycol). Surf Coat Technol 207:79–88. https://doi.org/10.1016/j.surfcoat.2012.06.00310.1016/j.surfcoat.2012.06.003 ↗
54. Bhosale RR, Shende RV, Puszynski JA (2012) Thermochemical water-splitting for H2 generation using sol-gel derived Mn-ferrite in a packed bed reactor. Int J Hydrog Energy 37:2924–2934. https://doi.org/10.1016/j.ijhydene.2011.03.01010.1016/j.ijhydene.2011.03.010 ↗
55. Yin Y, Wang C (2012) Organic–inorganic hybrid silica film coated for improving resistance to capsicum oil on natural substances through sol–gel route. J Sol-Gel Sci Technol 64:743–749. https://doi.org/10.1007/s10971-012-2911-710.1007/s10971-012-2911-7 ↗
56. Schmidt H, Jonschker G, Goedicke S, Mennig M (2000) The sol-gel process as a basic technology for nanoparticle-dispersed inorganic-organic composites. J Sol-Gel Sci Technol 19:39–51. https://doi.org/10.1023/A:100870600399610.1023/A:1008706003996 ↗
57. Vasiljević J, Tomšič B, Jerman I, Simončič B (2017) Organofunctional trialkoxysilane sol-gel precursors for chemical modification of textile fibres. Tekstilec 60:198–213. https://doi.org/10.14502/Tekstilec2017.60.198-21310.14502/Tekstilec2017.60.198-213 ↗
58. Plutino MR, Colleoni C, Donelli I et al. (2017) Sol-gel 3 -glycidoxypropyltriethoxysilane finishing on different fabrics: the role of precursor concentration and catalyst on the textile performances and cytotoxic activity. J Colloid Interface Sci 506:504–517. https://doi.org/10.1016/j.jcis.2017.07.04810.1016/j.jcis.2017.07.048 ↗
59. Serra A, Ramis X, Fernández-Francos X (2016) Epoxy sol-gel hybrid thermosets. Coatings 6:8. https://doi.org/10.3390/coatings601000810.3390/coatings6010008 ↗
60. Wen J, Wilkes GL (1996) Organic/inorganic hybrid network materials by the sol−gel approach. Chem Mater 8:1667–1681. https://doi.org/10.1021/cm960114310.1021/cm9601143 ↗
61. Schubert U, Huesing N, Lorenz A (1995) Hybrid Inorganic-organic materials by sol-gel processing of organofunctional metal alkoxides. Chem Mater 7:2010–2027. https://doi.org/10.1021/cm00059a00710.1021/cm00059a007 ↗
62. Sanchez C, Julián B, Belleville P, Popall M (2005) Applications of hybrid organic–inorganic nanocomposites. J Mater Chem 15:3559. https://doi.org/10.1039/b509097k10.1039/b509097k ↗
63. Boury B, Corriu RJP (2002) Auto-organisation of hybrid organic–inorganic materials prepared by sol–gel chemistry. Chem Commun 795–802. https://doi.org/10.1039/b109040m10.1039/b109040m ↗
64. Schmidt H (1985) New type of non-crystalline solids between inorganic and organic materials. J Non-Cryst Solids 73:681–691. https://doi.org/10.1016/0022-3093(85)90388-610.1016/0022-3093(85)90388-6 ↗
65. Sanchez C, Rozes L, Ribot F et al. (2010) “Chimie douce”: a land of opportunities for the designed construction of functional inorganic and hybrid organic-inorganic nanomaterials. Comptes Rendus Chim 13:3–39. https://doi.org/10.1016/j.crci.2009.06.00110.1016/j.crci.2009.06.001 ↗
66. Wolfbeis OS (2008) Fiber-optic chemical sensors and biosensors. Anal Chem 80:4269–4283. https://doi.org/10.1021/ac800473b10.1021/ac800473b ↗
67. Wolfbeis OS, Reisfeld R, Oehme I (1996) Sol-gels and chemical sensors. In: Aegerter MA, Mehrota RC, Oehme I, Reisfeld R, Sakka S, Wolfbeis OS, Jørgensen CK (eds) Optical and electronic phenomena in sol-gel glasses and modern application. Springer Berlin Heidelberg, Berlin, Heidelberg, pp 51–9810.1007/BFb0111488 ↗
68. Widmer S, Dorrestijn M, Camerlo A et al. (2014) Coumarin meets fluorescein: a Förster resonance energy transfer enhanced optical ammonia gas sensor. Analyst 139:4335–4342. https://doi.org/10.1039/C4AN00061G10.1039/C4AN00061G ↗
69. Shahamirifard SA, Ghaedi M, Hajati S (2018) A new silver (I) ions optical sensor based on nanoporous thin films of sol–gel by rose bengal dye. Sens Actuators B Chem 259:20–29. https://doi.org/10.1016/j.snb.2017.12.03010.1016/j.snb.2017.12.030 ↗
70. Chu C-S, Chuang C-Y (2015) Optical fiber sensor for dual sensing of dissolved oxygen and Cu2+ ions based on PdTFPP/CdSe embedded in sol–gel matrix. Sens Actuators B Chem 209:94–99. https://doi.org/10.1016/j.snb.2014.11.08410.1016/j.snb.2014.11.084 ↗
71. Liu D, Lian X, Mallik AK, et al. (2017) Detection of volatile organic compounds using an optical fiber sensor coated with a sol-gel silica layer containing immobilized Nile red. Proc. SPIE 10323, 25th International Conference on Optical Fiber Sensors, p 103232W10.1117/12.2263671 ↗
72. Dunbar ADF, Brittle S, Richardson TH et al. (2010) Detection of volatile organic compounds using porphyrin derivatives. J Phys Chem B 114:11697–11702. https://doi.org/10.1021/jp102755h10.1021/jp102755h ↗
73. Delmarre D, Méallet R, Bied-Charreton C, Pansu R (1999) Heavy metal ions detection in solution, in sol–gel and with grafted porphyrin monolayers. J Photochem Photobiol A Chem 124:23–28. https://doi.org/10.1016/S1010-6030(99)00046-510.1016/S1010-6030(99)00046-5 ↗
74. Feng L, Musto CJ, Kemling JW et al. (2010) Colorimetric sensor array for determination and identification of toxic industrial chemicals. Anal Chem 82:9433–9440. https://doi.org/10.1021/ac102088610.1021/ac1020886 ↗
75. Caldara M, Colleoni C, Guido E et al. (2012) Development of a textile-optoelectronic pH meter based on hybrid xerogel doped with Methyl Red. Sens Actuators B Chem 171–172:1013–1021. https://doi.org/10.1016/j.snb.2012.06.02410.1016/j.snb.2012.06.024 ↗
76. Guido E, Colleoni C, De Clerck K et al. (2014) Influence of catalyst in the synthesis of a cellulose-based sensor: kinetic study of 3-glycidoxypropyltrimethoxysilane epoxy ring opening by Lewis acid. Sens Actuators B Chem 203:213–222. https://doi.org/10.1016/j.snb.2014.06.12610.1016/j.snb.2014.06.126 ↗
77. Plutino MR, Guido E, Colleoni C, Rosace G (2017) Effect of GPTMS functionalization on the improvement of the pH-sensitive methyl red photostability. Sens Actuators B 238:281–291. https://doi.org/10.1016/j.snb.2016.07.05010.1016/j.snb.2016.07.050 ↗
78. Schottner G (2001) Hybrid sol−gel-derived polymers: applications of multifunctional materials. Chem Mater 13:3422–3435. https://doi.org/10.1021/cm011060m10.1021/cm011060m ↗
79. Rosace G, Guido E, Colleoni C et al. (2017) Halochromic resorufin-GPTMS hybrid sol-gel: chemical-physical properties and use as pH sensor fabric coating. Sens Actuators B Chem 241:85–95. https://doi.org/10.1016/j.snb.2016.10.03810.1016/j.snb.2016.10.038 ↗
80. Trovato V, Rosace G, Colleoni C, Plutino MR (2017) Synthesis and characterization of halochromic hybrid sol-gel for the development of a pH sensor fabric. IOP Conf Ser Mater Sci Eng 254:72027. https://doi.org/10.1088/1757-899X/254/7/07202710.1088/1757-899X/254/7/072027 ↗
81. Van der Schueren L, De Clerck K, Brancatelli G et al. (2012) Novel cellulose and polyamide halochromic textile sensors based on the encapsulation of Methyl Red into a sol-gel matrix. Sens Actuators B Chem 162:27–34. https://doi.org/10.1016/j.snb.2011.11.07710.1016/j.snb.2011.11.077 ↗
82. Caldara M, Colleoni C, Guido E, et al. (2013) A wearable sensor platform to monitor sweat pH and skin temperature. In: 2013 IEEE international conference on body sensor networks. IEEE, p 1–6. https://doi.org/10.1109/BSN.2013.657546510.1109/BSN.2013.6575465 ↗
83. Caldara M, Colleoni C, Guido E et al. (2016) Optical monitoring of sweat pH by a textile fabric wearable sensor based on covalently bonded litmus-3-glycidoxypropyltrimethoxysilane coating. Sens Actuators B Chem 222:213–220. https://doi.org/10.1016/j.snb.2015.08.07310.1016/j.snb.2015.08.073 ↗
84. Sun X-Z, Branford-White C, Yu Z-W, Zhu L-M (2015) Development of universal pH sensors based on textiles. J Sol-Gel Sci Technol 74:641–649. https://doi.org/10.1007/s10971-015-3643-210.1007/s10971-015-3643-2 ↗
85. Qiu X, Hu S (2013) “Smart” materials based on cellulose: a review of the preparations, properties, and applications. Materials 6:738–781. https://doi.org/10.3390/ma603073810.3390/ma6030738 ↗
86. Adedayo O, Javadpour S, Taylor C et al. (2004) Decolourization and detoxification of methyl red by aerobic bacteria from a wastewater treatment plant. World J Microbiol Biotechnol 20:545–550. https://doi.org/10.1023/B:WIBI.0000043150.37318.5f10.1023/B:WIBI.0000043150.37318.5f ↗
87. Ngwabebhoh FA, Erdem A, Yildiz U (2016) Synergistic removal of Cu(II) and nitrazine yellow dye using an eco-friendly chitosan-montmorillonite hydrogel: optimization by response surface methodology. J Appl Polym Sci 133:43664. https://doi.org/10.1002/app.4366410.1002/app.43664 ↗
88. Caldara M, Colleoni C, Guido E, Rosace G (2012) Optical sensor development for smart textiles. In: 12th World textile conference AUTEX 2012, p 1149–1452