Post-fire integrity of composite gratings for offshore platforms

AG Gibson, JK Humphrey, P Di-Modica, S Christke, G Kotsikos, R Holliday

Publisher page

Abstract

The post-fire integrity of pultruded phenolic/glass and polyester/glass floor gratings, of the type used offshore and elsewhere, was investigated. The aim was to determine whether glass/phenolic gratings may be safely walked on, post-fire, by offshore workers and fire-fighting teams. The load to be resisted was identified as equivalent to a running person carrying a load, the combined mass being 150 kg. The maximum resulting dynamic strains were determined by strain gauges on the undersides of the individual beam elements of gratings. This enabled target values of post-fire bending resistance to be identified. Individual beam elements from the gratings were exposed to heat fluxes of 12.5, 37.5 and 100 kW/m 2 using a propane burner, for periods up to 16 min, after which the residual strength was measured. Phenolic gratings showed longer ignition times, with lower flame and smoke emission, as well as greater post-fire strength compared to polyester ones. At the lowest flux, 12.5 kW/m 2 , all gratings remained serviceable beyond 16 min. At higher heat fluxes, the phenolic gratings retained some post-fire strength, assisted by the formation of a carbonaceous char binding the fibres. However, this was somewhat below the target level. A study of the effect of testing speed indicated that fire-exposed gratings are not especially strain-rate sensitive.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Fire effects on concrete materials · Fire dynamics and safety research · Combustion and Detonation Processes

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

School of Mechanical and Systems Engineering, Newcastle University, UK

MMI Engineering Ltd, AVC Business Centre, UK

References (17)

Show source-provided references
1. U.S. Coast Guard Policy File Memorandum (PFM) 2-98: Guide for use of fiber reinforced plastic (GRP) gratings and cable trays.
2. NORSOK S-001. Tech Saf Ed. 4 February 2008.
3. 10.1179/174328907X24821210.1179/174328907X248212 ↗
4. 10.1002/1099-1018(200003/04)24:2<67::AID-FAM720>3.0.CO;2-010.1002/1099-1018(200003/04)24:2<67::AID-FAM720>3.0.CO;2-0 ↗
5. 10.1016/S0263-8223(00)00043-X10.1016/S0263-8223(00)00043-X ↗
6. 10.1023/A:101452062891510.1023/A:1014520628915 ↗
7. 10.1016/j.polymdegradstab.2007.11.02710.1016/j.polymdegradstab.2007.11.027 ↗
8. ISO 22899:2007. Resistance to jet fires of passive fire protection materials.
9. 10.1177/002199831142938310.1177/0021998311429383 ↗
10. IMO Resolution A.753(18). Guidelines for the application of plastics pipes on ships 22 November 1993.
11. ISO 14692-2:2002. Petroleum and natural gas industries—glass-reinforced plastic (GRP) piping. Part 2: Qualification and manufacture.
12. ISO 13702:1999. Petroleum and natural gas industries—control and mitigation of fires and explosions on offshore production installations—requirements and guidelines.
13. Spouge J. CMPT. A guide to quantitative risk assessment for offshore installations. DNV Technica 1999.
14. MMU289-P01-TN02 Issue 1. Fire resistance testing of FRP gratings—anthropometric data for loading of test specimens. MMI Engineering 2012.
15. Yokoyama Y Ito K Matsunaga K et al. The relationship between moving velocity and load caused by human walking and running from a viewpoint of slipperiness and floor vibration. In: Summaries of technical papers of annual meeting Tokai Branch AIJ No. 35 February 1997 pp.53–56.
16. Offshore Standard DNV-05-C501:2010. Composite components.
17. 10.1007/s10853-008-3140-x10.1007/s10853-008-3140-x ↗