journal article·2003-09

Seismic Performance of Aramid Fiber Square Tubed Concrete Columns with Metallic and/or Non-Metallic Reinforcement

T. Yamakawa, P. Zhong, A. Ohama

Publisher page

Abstract

In prefabricated Aramid Fiber Reinforced Polymer (AFRP) tubed concrete columns with metallic and/or nonmetallic reinforcement, the AFRP square tube performs the dual functions of stay-in-place formwork and transverse reinforcement. Nine column specimens including a hybrid concrete column with steel bars or AFRP rods for longitudinal reinforcement, were tested under cyclic lateral forces while simultaneously subjected to a constant axial load. Double confinement due to an aramid fiber tube and steel hoops with cross ties can provide a much greater transverse confinement effect. The ply of composite laminates can be designed such that when the shear and the bond strengths exceed the flexural strengths, adequate seismic performance of the hybrid RC columns can be ensured.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Structural Behavior of Reinforced Concrete · Innovative concrete reinforcement materials · Microbial Applications in Construction Materials

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Civil Engineering and Architecture

School of Engineering and Science University of the Ryukyus Okinawa,903-0213,Japan

References (7)

Show source-provided references
1. 1. The Building Disaster Prevention Association of Japan (BDPAJ). (1999). Guidelines for Seismic Retrofit Design and Construction of Existing Reinforced Concrete and Steel Reinforced Concrete Buildings Utilizing Continuous Fiber Reinforcing Material, Japan (In Japanese).
2. 2. Seible, F., Hegemier, G., Karbhari, V., Burgueno, R. and Davol, A. (1997). The Carbon Shell System for Modular Short and Medium Span Bridges, International Composites EXPO'97 Session 3-D/1-6.
3. 3. Yamakawa, T. and Zhong, P. (1999). Seismic Performance of RC Columns Laterally Confined by Carbon Fiber Reinforcing Plastic Tube, Specialist Techniques and Materials for Concrete Construction, 455-463, Thomas Telford, UK .10.1680/stamfcc.28258.0043 ↗
4. 4. Yamakawa, T., Satoh, H. and Zhong, P. (1999). Seismic Performance of Hybrid Reinforced Concrete Circular Columns Confined in Aramid Fiber Reinforced Polymer Tube , Fourth International Symposium on Fiber Reinforced Polymer Reinforcement for Reinforced Concrete Structures, 1089-1102 , American Concrete Institute, USA.
5. 5. Yamakawa, T. & Zhong, P. (2001). Seismic Performance of Hybrid RC Columns Confined in Aramid Fiber Reinforced Polymer Square Tube , Proceedings of the First International Structural Engineering and Construction Conference Creative Systems in Structural and Construction Engineering, 769-774 , USA.
6. 6. Architectural Institute of Japan (AIJ). (1999). AIJ Standard for Structural Calculation of Reinforced Concrete Structures-Based on Allowable Stress Concept-revised 1999, AIJ, Japan (In Japanese).
7. 7. Architectural Institute of Japan (AIJ). (1999). Design Guidelines for Earthquake Resistant Reinforced Concrete Buildings based on Inelastic Displacement Concept, AIJ, Japan (In Japanese).