Tests of high-performance fiber-reinforced concrete beams with different shear span-to-depth ratios and main longitudinal reinforcement
Source abstract
Abstract
Test results of 12 reinforced concrete (RC) beams having three shear span to effective depth ratios and two main longitudinal reinforcement amounts are reported. Six of the test specimens were produced with engineered cementitious composites (ECCs) and another corresponding six with ultra high-strength fiber-reinforced cementitious composite (RMC). The shear span to effective depth ratios of test specimens were selected low to investigate the shear performance of ECCs and RMC characterized by ultra high ductility-moderate strength and ultra high strength-moderate ductility, respectively. Shear-carrying capacity and ductility ratios of large-scale reinforced ECC and RMC beams were compared and interpreted for different shear spans, energy absorption capacities, and stiffnesses. The experimental results showed that for the three different shear spans, the RMC beams had higher shear capacity results than the ECC beams. Using both concrete types markedly restricted shear cracking and led to flexural failure. Overall findings suggest that RMC beams have higher shear capacity and yield stiffness than ECC beams, while ECC beams have a higher deflection ductility ratio and energy absorption capacity.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Innovative concrete reinforcement materials · Structural Behavior of Reinforced Concrete · Concrete and Cement Materials Research
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Civil Engineering, Ryerson University, Toronto, ON, Canada
Department of Civil Engineering, Gazi University, Ankara, Turkey
School of Engineering, Bradford University, West Yorkshire, UK
References (16)
Show source-provided references
1. Bentz EC · ACI Struct J · 2006 · 103 · 614
2. 10.1680/macr.2008.60.9.63510.1680/macr.2008.60.9.635 ↗
3. Nilson AH · ACI Special Publ · 1985 · 87 · 85
4. Swamy RN · ACI Special Publ · 1985 · 87 · 110
5. Naaman AE and Reinhardt HW. Setting the stage: Toward performance-based classification of FRC composites. In: High performance fiber reinforced cement composites (HPFRCC-4) , Published by RILEM S.A.R.L., 2003, pp. 1–4.10.1007/BF02479507 ↗
6. Li VC. Engineered cementitious composites tailored composites through micromechanical modeling. In: Fiber reinforced concrete: Present and the future . Westmount, QC: Canadian Society for Civil Engineering, 1998, pp. 64–97.
7. 10.3151/jact.1.21510.3151/jact.1.215 ↗
8. 10.1016/S0022-5096(96)00095-610.1016/S0022-5096(96)00095-6 ↗
9. Lin Z · Concr Sci Eng · 1999 · 1 · 173
10. Ametrano D. Bond characteristics of glass fibre reinforced polymer bars embedded in high performance and ultra-high performance concrete . MS Thesis, Ryerson University, Toronto, ON, Canada, 2011, pp. 1–132.
11. 10.1061/(ASCE)MT.1943-5533.000050510.1061/(ASCE)MT.1943-5533.0000505 ↗
12. 10.1016/1065-7355(94)90045-010.1016/1065-7355(94)90045-0 ↗
13. Li VC · ACI Mater J · 2002 · 99 · 11
14. 10.1016/j.cemconres.2007.04.00910.1016/j.cemconres.2007.04.009 ↗
15. MacGregor JG · 1997
16. Yang E · ACI Mater J · 2009 · 106 · 357