journal article·2012-03

Prepreg age monitoring via differential scanning calorimetry

Lessa K. Grunenfelder, Steven R. Nutt

Publisher page

Abstract

Fabrication of composite parts from prepregs often requires layup and preparation times of days and even weeks, during which prepregs undergo room-temperature aging. The aging process can compromise compaction, tack, and overall quality of composite parts, and thus a need exists for an accurate and convenient method to monitor the extent of prepreg aging as a function of out-time. Here, we report a method to monitor prepreg age, which involves measurement of changes in glass transition temperature as a function of room-temperature aging time. Samples from three out-of-autoclave prepreg systems were aged in ambient conditions and tested periodically using modulated differential scanning calorimetry. A linear increase in glass transition temperature with prepreg age was noted. Results are discussed in the context of monitoring the chemical aging of epoxy resins that occurs at ambient temperature.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Epoxy Resin Curing Processes · Polymer crystallization and properties · Mechanical Behavior of Composites

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Chemical Engineering and Materials Science, University of Southern California, Los Angeles, CA, USA

References (22)

Show source-provided references
1. RepeckaL. and BoydJ.. Vacuum-bag-only-curable prepregs that produce void free parts. In: 47th International SAMPE Symposium. CA: Long Beach May 1216 2002 pp. 1862–1875.
2. JacksonK. and CrabtreeM.. Autoclave quality composites tooling for composite from vacuum bag only processing. In: 47th International SAMPE Symposium. CA: Long Beach May 12-16 2002 pp. 800-807.
3. 10.1016/j.compositesa.2008.03.01510.1016/j.compositesa.2008.03.015 ↗
4. CrabtreeD.J.. Quantitative analysis of resin matrix aging by gel permeation chromatography and differential scanning calorimetry. ASC Symposium Series. Am Chem Soc 1980; 459–468.
5. MillerS.G., HouT-H, SutterJ.K. Out-life characteristics of IM7/977-3 composites. SAMPE Fall Technical Conference.UT: Salt Lake City, October 11 14, 2010.
6. 10.1002/pc.2065910.1002/pc.20659 ↗
7. 10.1002/pc.1045410.1002/pc.10454 ↗
8. 10.1016/0266-3538(90)90021-V10.1016/0266-3538(90)90021-V ↗
9. 10.1021/ie801800510.1021/ie8018005 ↗
10. 10.1002/pc.75010030310.1002/pc.750100303 ↗
11. 10.1002/pc.75012031110.1002/pc.750120311 ↗
12. 10.1177/09673911020100080310.1177/096739110201000803 ↗
13. GrunenfelderL.K., and NuttS.R.. Out time effects on VBO prepreg and laminate properties. In: SAMPE Conference. CA: Long Beach, May 23-26, 2011.
14. 10.1002/pc.75008040610.1002/pc.750080406 ↗
15. 10.1002/pc.75001020610.1002/pc.750010206 ↗
16. 10.1002/app.1992.07045030410.1002/app.1992.070450304 ↗
17. 10.1002/pen.76021080710.1002/pen.760210807 ↗
18. 10.1016/S0378-5173(99)00267-710.1016/S0378-5173(99)00267-7 ↗
19. 10.1007/BF0254685210.1007/BF02546852 ↗
20. 10.1002/polb.1990.09028090610.1002/polb.1990.090280906 ↗
21. 10.1002/pol.1955.12015800610.1002/pol.1955.120158006 ↗
22. 10.1002/macp.20080021710.1002/macp.200800217 ↗