An experimental study of temperature distribution in an autoclave
Source abstract
Abstract
In this work, the temperature distribution on an industrial mold tool is monitored during autoclave runs with three settings. In one of the settings, the temperature and pressure follow a scheme used in real moldings, while in the other two cases, the temperature is increased as fast as possible with and without an applied pressure. The temperature difference over the tool is relatively large and varies between 29℃ and 76℃ validating a detailed investigation of the temperature at different points. Two results of this are that positions on the up-stream side of the tool are heated faster than positions down-stream and the heating over the tool is symmetric while that within is asymmetric. Roughly estimated heat transfer coefficients reveal that the temperature ramping has no significant effect on the local heat transfer coefficients while the applied pressure more than doubled them. In addition flow field measurements with particle image velocimetry are performed, revealing a very slow flow near the roof of the autoclave and a velocity peak near the floor of it, indicating that the flow profile within the autoclave and variation in heat transfer coefficients should be considered in autoclave simulations.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Injection Molding Process and Properties · Epoxy Resin Curing Processes · Rheology and Fluid Dynamics Studies
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Division of Fluid and Experimental Mechanics, Luleå University of Technology, Luleå, Sweden
SAAB Aerostructures, Linköping, Sweden
References (25)
Show source-provided references
1. 10.1016/j.compositesa.2004.03.01910.1016/j.compositesa.2004.03.019 ↗
2. 10.1179/146580109X1254099504588610.1179/146580109X12540995045886 ↗
3. 10.1108/0961553031046455310.1108/09615530310464553 ↗
4. 10.1002/pc.2009010.1002/pc.20090 ↗
5. 10.1002/pc.1016210.1002/pc.10162 ↗
6. 10.1002/pc.2285610.1002/pc.22856 ↗
7. 10.1016/0924-0136(90)90152-K10.1016/0924-0136(90)90152-K ↗
8. 10.1177/002199831142961810.1177/0021998311429618 ↗
9. 10.1016/0010-4361(86)90250-810.1016/0010-4361(86)90250-8 ↗
10. 10.1016/j.compscitech.2010.09.00910.1016/j.compscitech.2010.09.009 ↗
11. 10.1016/j.compstruct.2005.02.00110.1016/j.compstruct.2005.02.001 ↗
12. 10.1016/0010-4361(95)96808-J10.1016/0010-4361(95)96808-J ↗
13. 10.1002/pc.1028210.1002/pc.10282 ↗
14. 10.1163/15685510332232037410.1163/156855103322320374 ↗
15. 10.1016/S0266-3538(98)00138-910.1016/S0266-3538(98)00138-9 ↗
16. 10.1016/0735-1933(94)90032-910.1016/0735-1933(94)90032-9 ↗
17. Oh JH and Lee DG. Cure cycle for thick glass/epoxy composite laminates. J Compos Mater 2002; 36(1): 19–45.10.1177/0021998302036001300 ↗
18. 10.1016/j.compscitech.2004.07.01510.1016/j.compscitech.2004.07.015 ↗
19. Slesinger N, Shimizu T, Arafath ARA, et al. Heat transfer coefficient distribution inside an autoclave. In: ICCM-17 , 21–27 July 2009, Edinburgh, UK.
20. 10.1177/073168440809387610.1177/0731684408093876 ↗
21. Bejan A · 1993
22. Green TM. PIV in practice . Doctoral thesis, Department of Engineering Sciences and Mathematics, Luleå University of Technology, Luleå (2011).
23. Green TM, et al. Flow characterization of an attraction channel as entrance to fishways. River Res Appl 2011; 27: 1290–1297.10.1002/rra.1426 ↗
24. 10.1007/s00348-012-1309-110.1007/s00348-012-1309-1 ↗
25. Nordling C · 2008