Ductility Evaluation of Prestressed Concrete Beams with CFRP Tendons
Source abstract
Abstract
Conventional definition of ductility index which are based on yielding of the reinforcement, are inappropriate for the evaluation of structural ductility of concrete beams reinforced or prestressed with FRP tendons. In this paper, a new definition of ductility index is expressed as the ratio of the total energy to the elastic energy at the failure state of a beam. It is applicable to beams with steel as well as brittle FRP reinforcements, thus providing a common basis for comparison. From the experimental results of prestressed concrete beams, the beams with a carbon fiber reinforcement plastic (CFRP) tendon have higher flexural cracking load, flexural yielding load, and flexural fracture load. While the displacement at the fracture stage was lower compared to steel tendons, excessive steel reinforcement lead to a lower ductility index. Prestressed concrete beam with a CFRP tendon have sufficient ductility when ruptured by crushing of concrete or used with unbonded tendon. Accordingly, ductility of structure could be secured by overcoming reinforcement failure as inducing compress-controlled failure based on overreinforcement designs in the beam which is used in CFRP tendons. Therefore, the practical design method for prestressed concrete beams with CFRP tendons turn out to be overreinforcement, and use of unbonded tendon.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Structural Behavior of Reinforced Concrete · Concrete Corrosion and Durability · Innovative concrete reinforcement materials
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Hanyang University Department of Civil Engineering Seoul, Korea
References (8)
Show source-provided references
1. 1. Shin Hyun Muk (1996). Prestressed Concrete, Dong Myung Coperation.
2. 2. Sang Yeol Park (1995). Shear Behavior of Prestressed Concrete Beams Using Fiber Reinforced Tendons, Ph. D. Dissertation, The University of Michigan, December, 1995.
3. 3. L.E. Holte, C.W. Dolan and R.J. Schmidt (1993). Epoxy Socket Anchors for Non-Metalic Pres Tendons, FRP Reinforcement for Concrete Structures , In: Proceedings of International Symposium, ACI American Concrete Institute, pp. 381–400 .
4. 4. C.V. Jerrett, S.H. Ahmad and G. Scotti (1996). Behavior of Prestressed Concrete Beams Strength by External FRP Post-Tensioned Tendons, Advanced Composite Materials in Bridges and Structures Society for Civil Engineering, 305–112.
5. 5. H. Mutsuyoshi and A. Machida (1993). Behavior of Prestressed Concrete Beams using FRP as Cable, FRP Reinforcement for Concrete Structures , In: Proceedings of International Symposium, ACI American Concrete Institute, pp. 401–417 .
6. 6. C.J. Burgoyne (1993). Should FRP be Bonded to Concrete, FRP Reinforcement for Concrete Structures , In: Proceedings of International Symposium, American Concrete Institute, SP-138-23, pp. 367–380 .
7. 7. T. Kato and N. Hayashida (1994). Flexural Characteristics of Prestressed Concrete Beams with Tendons, FRP Reinforcement for Concrete Structures , In: Proceedings of International Sympoisum, American Concrete Institute, pp. 419–439 .
8. 8. A.E. Naaman and S.M. Jeong (1994). Structural Ductility of Concrete Beams Prestressed with FRP Non-Metalic Reinforcement for Concrete Structures , In: Proceedings of the 2nd International Rilem Sy London, pp. 379–386 .