DRT-based impedance analysis of two-phase flow conditions in PEM water electrolyzer cells
Source abstract
Abstract
The accumulation of hydrogen and oxygen within the flow channels of proton exchange membrane water electrolysis cells results in increased gas fractions and pronounced two-phase flow effects at higher current densities. Spatially resolved segmentation along the channel permits investigation of such gradients but necessitates complex hardware. In this study, a simplified method is introduced to emulate local gas production in an incremental cell through controlled injection of well-defined amounts of hydrogen and oxygen into the respective inlet streams. The impact of the gas-to-water ratio on ohmic resistance and polarization phenomena is examined using electrochemical impedance spectroscopy combined with subsequent distribution of relaxation times analysis. This reveals membrane dehydration effects as well as an impact on activation-related losses on the cathode side. A detailed comparison between an incremental (zero gradient) cell and an along-the-channel cell demonstrates a good overall performance correlation. In the medium current density region (2-3 A cm −2 ), the along-the-channel cell shows significantly increased polarization losses, which might be attributed to contamination from ion release from the CCM and/or mass transport issues.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Hybrid Renewable Energy Systems · Fuel Cells and Related Materials · Integrated Energy Systems Optimization
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (36)
Show source-provided references
1. Recent and future advances in water electrolysis for green hydrogen generation: critical analysis and perspectives10.3390/su152416917 ↗
2. Green hydrogen: pathway to net zero green house gas emission and global climate change mitigation10.3390/hydrogen6020029 ↗
3. Green hydrogen: a strategic energy vector for achieving net-zero emissions by 205010.1039/D5SE00902B ↗
4. A comprehensive review on coupling different types of electrolyzer to renewable energy sources10.1016/j.energy.2018.06.073 ↗
5. Proton exchange membrane electrolyzer systems operating dynamically at high current densities10.1149/07223.0011ecst ↗
6. Dynamic operation of water electrolyzers: a review for applications in photovoltaic systems integration
7. Hydrogen production by water electrolysis: a review of alkaline water electrolysis, PEM water electrolysis and high temperature water electrolysis
8. Proton exchange membrane (PEM) water electrolysis: cell-level considerations for gigawatt-scale deployment10.1021/acs.chemrev.3c00904 ↗
9. Durable membrane electrode assemblies for proton exchange membrane electrolyzer systems operating at high current densities10.1016/j.electacta.2016.04.164 ↗
10. An analysis of PEM water electrolysis cells operating at elevated current densities10.1016/j.ijhydene.2018.11.179 ↗
11. Hydrogen crossover in PEM water electrolysis at current densities up to 10 A cm−210.1149/1945-7111/ac908c ↗
12. In-situ investigation of bubble dynamics and two-phase flow in proton exchange membrane electrolyzer cells10.1016/j.ijhydene.2018.05.006 ↗
13. Two-phase flow behaviour and performance of polymer electrolyte membrane electrolysers: electrochemical and optical characterisation10.1016/j.ijhydene.2018.07.003 ↗
14. Effect of flow regime of circulating water on a proton exchange membrane electrolyzer10.1016/j.ijhydene.2010.06.103 ↗
15. A segmented along the channel test cell for locally resolved analysis at high current densities in PEM water electrolysis10.1149/1945-7111/ad9064 ↗
16. Understanding the cell performance along the channel for industrial PEM water electrolysis operation10.1021/acsaem.5c00505 ↗
17. Local current density and electrochemical impedance measurements within 50 cm single-channel PEM electrolysis cell10.1149/2.0411816jes ↗
18. Influence of the porous transport layer properties on the mass and charge transfer in a segmented PEM electrolyzer10.1016/j.ijhydene.2020.01.100 ↗
19. Water starvation phenomena in a segmented along the channel PEM water electrolysis cell10.1016/j.jpowsour.2025.237865 ↗
20. Quantitative investigation of internal polarization in a proton exchange membrane water electrolyzer stack using distribution of relaxation times10.1016/j.apenergy.2025.125543 ↗
21. Interpreting full-frequency impedance spectrum for PEM electrolyzers: distribution of relaxation times-based modeling10.1016/j.apenergy.2025.126185 ↗
22. Identifying electrochemical processes by distribution of relaxation times in proton exchange membrane electrolyzers10.1016/j.jpowsour.2024.235850 ↗
23. Application of distribution of relaxation times method in polymer electrolyte membrane water electrolyzer
24. Distribution of relaxation times-based impedance analysis of incremental PEM water electrolysis cells10.1016/j.ijhydene.2026.154048 ↗
25. On the influence of the anodic porous transport layer on PEM electrolysis performance at high current densities10.1016/j.ijhydene.2019.12.204 ↗
26. Advances in benchmarking and round robin testing for PEM water electrolysis: reference protocol and hardware10.1016/j.apenergy.2023.121898 ↗
27. Mass transport in PEM water electrolysers: a review10.1016/j.ijhydene.2021.10.013 ↗
28. Water transport according to temperature and current in PEM water electrolyzer10.1016/j.ijhydene.2019.10.209 ↗
29. On the nature of electro-osmotic drag10.3390/en13184726 ↗
30. A method for improving the robustness of linear kramers-kronig validity tests10.1016/j.electacta.2014.01.034 ↗
31. Evaluation of electrochemical impedance spectra by the distribution of relaxation times
32. Inductive low‐frequency processes in PEMFC‐Impedance spectra10.1002/fuce.201900212 ↗
33. 1995 · vol.328
34. Kinetic origin of the sub-nernstian cell voltage response in pressurised PEM water electrolysis10.1016/j.ijhydene.2026.154454 ↗
35. Inductive loops in impedance spectra of PEM water electrolyzers10.1016/j.jpowsour.2024.235375 ↗
36. Performance losses and current-driven recovery from cation contaminants in PEM water electrolysis10.1149/1945-7111/ad576b ↗