Corrigendum to high performance metal-supported solid oxide fuel cells with infiltrated electrodes [Journal of Power Sources 410–411 (2019) 91–98]
Source abstract
Abstract
Author(s): Dogdibegovic, E; Wang, R; Lau, GY; Tucker, MC | Abstract: The authors regret that a technical mistake has been discovered, which impacts the current density and power density reported in this article. Briefly, the mistake was caused by catalyst solution leaking out of the intended 1 cm2 catalyzed area and depositing catalyst over the whole cell. As a result, the calculated current and power densities (total divided by the catalyzed area) were higher than reality because the measured current and power were dividing by the intended 1 cm2 instead of the actual area including the leakage, which was approximately 5 cm2. This issue is presented, analysed, and discussed in further detail in the supporting information of Reference 1. The authors would like to apologise for any inconvenience caused.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Fuel Cells and Related Materials · Advancements in Solid Oxide Fuel Cells · Machine Learning and ELM
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (1)
Show source-provided references
1. Dogdibegovic · J. Power Sources · 2021 · 48910.1016/j.jpowsour.2020.229439 ↗