Integrated fuel cell system with tubular solid oxide fuel cells
Source abstract
Abstract
An integrated fuel cell system based on tubular fuel cells is examined. The system relies on free convection to pass air and spent gas through the system by using a chimney. Thus, an expensive air supply mechanism is not required. It is shown that the use of free convection up to a power generating scale of around 2 kW is feasible. Factors determining the dimensions of the heat exchanging system are studied. A complete system capable of generating 2 kW of electricity, running on natural gas and ambient air, is anticipated to have a diameter of approximately 300 mm and a height of 1700 mm. Including the chimney a total height of 5 m was found.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Advancements in Solid Oxide Fuel Cells · Fuel Cells and Related Materials · Solar Energy Systems and Technologies
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (7)
Show source-provided references
1. H.H. Möbius, B. Rohland, US patent 3,377,203, 1968.
2. Boersma · J. Aust. Ceram. Soc. · 1998 · 34 · 242
3. K. Kendall, M. Prica, in: U. Bossel (Ed.), 1st European Solid Oxide Fuel Cell Forum, Lucerne, 1994, p. 163.
4. R.J. Boersma, N.M. Sammes, C.J. Fee, Solid State Ionics, 1999, in print.
5. R.J. Boersma, N.M. Sammes, C. Fee, in: S.C. Singhal (Ed.), Proc. of the 6th SOFC Conference, Honolulu, Hawaii, 1999, in print.
6. Stephan · Chem.-Ing.-Tech. · 1962 · 34 · 20710.1002/cite.330340313 ↗
7. R. Byron Bird, W.E. Stewart, E.N. Lightfoot, Physical Transport Phenomena, 1960.