Battery impedance characterization through inspection of discharge curve and testing with short pulses
Source abstract
Abstract
A simple method is proposed for battery impedance characterization at low frequencies (relevant to the electrochemical processes) and at higher frequencies (relevant to the double-layer process). The electrochemical impedance at very low frequencies is described using discharge curve information. This method makes it possible to distinguish between outwardly similar batteries that differ in backup times. The double-layer impedance at higher frequencies is characterized using short testing pulses. It is shown that the double-layer impedance of the negative electrode is observable in hertz range while the positive electrode is observable at the boundary to the millihertz range. The double-layer impedance of deeply discharged battery is observable at higher frequencies than the impedance of fully charged (or significantly discharged) battery because the electrodes are less overlapping in frequency and the spectrum shift to the higher frequencies is larger especially for the negative electrode.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Advanced Battery Technologies Research · Fuel Cells and Related Materials
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (5)
Show source-provided references
1. Conductance testing compared to traditional methods of evaluating the capacity of valve-regulated lead/acid batteries and predicting state-of-health10.1016/0378-7753(92)80056-H ↗
2. A method for measurement and interpretation of impedance spectra for industrial batteries10.1016/S0378-7753(99)00385-7 ↗
3. The non-linear low-frequency impedance of lead/acid batteries during discharge, charge and float operation
4. On-line battery testing: a reliable method for determining battery health
5. Method for battery impedance analysis10.1149/1.1697413 ↗