Quick crossover current measurement of a polymer electrolyte fuel cell stack with and without cell voltage terminals
Source abstract
Abstract
Abstract Crossover current (COC) measurement is an important diagnostic method for a polymer electrolyte fuel cell. Although a COC measurement method for single cells has already been established, a considerable amount of time is required to individually measure the COC of cells in a stack. Herein, we proposed two new methods to measure the COC of all cells in a stack quickly without the risk of electrode deterioration owing to overvoltage, even in a stack with a large COC difference between the cells. The first method was applied to a stack with cell voltage terminals in which parallel resistors are connected to each cell, and the COC of each cell is simultaneously measured via current scanning. The other method was applicable to a stack without cell voltage terminals in which the COC is obtained from the open-circuit voltage decay characteristics of the stack after applying direct voltage instantaneously. The measurement accuracy of these two methods was verified using a layered stack comprising four cells with different electrolyte membrane thicknesses.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Fuel Cells and Related Materials · Analytical Chemistry and Sensors · Electrocatalysts for Energy Conversion
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (32)
Show source-provided references
1. New Energy and Industrial Technology Development Organization(NEDO), A single cell evaluation and analysis protocol, http://www.nedo.go.jp/content/100537904.pdf.
2. A review of polymer electrolyte membrane fuel cell stack testing10.1016/j.jpowsour.2010.07.072 ↗
3. Diagnostic tools in PEM fuel cell research: Part II Physical/chemical methods10.1016/j.ijhydene.2008.01.020 ↗
4. Diagnostic tools in PEM fuel cell research: Part I Electrochemical techniques10.1016/j.ijhydene.2008.01.013 ↗
5. Proton exchange membrane fuel cell degradation under close to open-circuit conditions Part I: in situ diagnosis10.1016/j.jpowsour.2009.08.095 ↗
6. In situ measurement of active catalyst surface area in fuel cell stacks10.1016/j.jpowsour.2013.05.046 ↗
7. Development of new test instruments and protocols for the diagnostic of fuel cell stacks10.1016/j.jpowsour.2010.08.029 ↗
8. Improved electrochemical in-situ characterization of polymer electrolyte membrane fuel cell stacks10.1016/j.jpowsour.2015.12.070 ↗
9. Use of galvanostatic charge method as a membrane electrode assembly diagnostic tool in a fuel cell stack10.1016/j.jpowsour.2013.05.201 ↗
10. Development of a galvanostatic analysis technique as an in-situ diagnostic tool for PEMFC single cells and stacks10.1016/j.ijhydene.2011.12.152 ↗
11. Degradation of a polymer exchange membrane fuel cell stack with Nafion® membranes of different thicknesses: Part I. In situ diagnosis10.1016/j.jpowsour.2010.06.023 ↗
12. Characterization of gas crossover and its implications in PEM fuel cells10.1002/aic.10780 ↗
13. Measurement of ohmic voltage losses in individual cells in a PEMFC stack10.1016/S0378-7753(02)00391-9 ↗
14. Model based PEM fuel cell state-of-health monitoring via ac impedance measurements10.1016/j.jpowsour.2005.11.035 ↗
15. Multiphysics DC and AC models of a PEMFC for the detection of degraded cell parameters10.1016/j.ijhydene.2013.04.057 ↗
16. Detection of fuel cell critical status by stack voltage analysis10.1016/j.jpowsour.2006.01.009 ↗
17. On-line diagnosis of a PEM fuel cell
18. AC impedance technique in PEM fuel cell diagnosis — a review10.1016/j.ijhydene.2007.05.036 ↗
19. AC impedance diagnosis of a 500W PEM fuel cell stack Part I: stack impedance10.1016/j.jpowsour.2006.05.003 ↗
20. AC impedance diagnosis of a 500W PEM fuel cell stack Part II: individual cell impedance10.1016/j.jpowsour.2006.07.020 ↗
21. Simultaneous electrochemical impedance spectroscopy of single cells in a PEM fuel cell stack10.1016/j.jpowsour.2005.10.055 ↗
22. Relationship between pressure drop and cell resistance as a diagnostic tool for PEM fuel cells10.1016/j.jpowsour.2004.08.055 ↗
23. Dominant frequency of pressure drop signal as a novel diagnostic tool for the water removal in proton exchange membrane fuel cell flow channel10.1016/j.jpowsour.2009.09.003 ↗
24. Hydrogen pressure drop characteristics in a fuel cell stack10.1016/j.ijhydene.2005.08.008 ↗
25. Diagnosis of PEM fuel cell stack dynamic behaviors10.1016/j.jpowsour.2007.11.038 ↗
26. Model-based fault diagnosis in PEM fuel cell systems10.1016/j.jpowsour.2008.12.014 ↗
27. Diagnosis methods dedicated to the localization of failed cells within PEMFC stacks10.1016/j.jpowsour.2007.12.038 ↗
28. Identification of failed cells inside PEMFC stacks in two cases: anode/cathode crossover and anode/cooling compartment leak10.1016/j.ijhydene.2009.05.015 ↗
29. A review of polymer electrolyte membrane fuel cell durability test protocols10.1016/j.jpowsour.2011.07.082 ↗
30. Gas-leak-induced pinhole formation at polymer electrolyte membrane fuel cell electrode edges10.1016/j.ijhydene.2016.11.038 ↗
31. Degradation of a PEM fuel cell stack with Nafion® membranes of different thicknesses. Part II: Ex situ diagnosis10.1016/j.jpowsour.2012.01.074 ↗
32. The single cell testing protocol utilizing JARI standard single cell