journal article·2003-07

Study of multistage oxidation by flowsheet calculations on a combined heat and power molten carbonate fuel cell plant

S.F. Au, N. Woudstra, K. Hemmes

Journal of Power Sources· Volume 122· Issue 1
Publisher page

Abstract

Abstract The multistage oxidation configuration consists of a set of serially connected fuel cell stacks. By connecting the stacks serially, more homogenous current distribution over the cell surface can be achieved resulting in lower irreversible losses. This article presents a detailed assessment of multistage oxidation by flowsheet calculations in which the influence of operating temperature and gas composition on the fuel cell performance is incorporated. A 250 kW molten carbonate fuel cell (MCFC) combined heat and power (CHP) plant is used as reference and the fuel cell stack unit is substituted by two serially connected units ( N =2). Two multistage configurations are examined: (A) both anode and cathode flows are serially connected; (B) only the anode flow is serially connected while the cathode flow is parallel connected. For all systems, the total cell active area, cell current density, overall fuel utilization and gas temperature at the inlet and outlet of the fuel cell array are kept constant. Fuel cell performance at the operating conditions is calculated using a numerical model of the flowsheeting program. Influences of operating temperature and gas composition on the cell performance are incorporated using empirical relations that describe irreversible losses of the cell as function of these parameters. System performances are compared in order to assess the benefits of the multistage oxidation configurations. Differences in performance between the two multistage oxidation configurations are studied by analyzing the difference in exergy loss of stacks, stack power output, cooling requirement and cathode gas massflow and composition. Detailed flowsheet calculations show that the improvement in efficiency is about 0.6% for configuration A, and 0.8% for configuration B. Improvements are obtained by the enhanced fuel cell power output while the expander power output is slightly reduced. Heat output is slightly reduced due to the improved fuel cell conversion. Analysis of stack output revealed a intricate interaction between stack and the rest of the fuel cell system. Their mutual influences are examined and the results explain differences in results between configuration A and B.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Electrocatalysts for Energy Conversion · Advancements in Solid Oxide Fuel Cells · Fuel Cells and Related Materials

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (13)

Show source-provided references
1. S.F. Au, W.H.A. Peelen, F.R.A.M. Standaert, K. Hemmes, I. Uchida, Verification of Analytical Fuel Cell Models by Performance Testing at a 110 cm2 Molten Carbonate Fuel Cell, Pennington, NJ, USA, 2000, pp. A1051–A1057, J. Electrochem. Soc.148 (10).10.1149/1.1396335 ↗
2. F. Standaert, K. Hemmes, N. Woudstra, Nernst loss and multistage oxidation in fuel cells, in: Proceedings of the Fuel Cell Seminar, 16–19 November 1998, Palm Spring, California, USA, pp. 92–95.
3. F. Standeart, Analytical Fuel Cell Modelling and Exergy Analysis of Fuel Cells, Ph.D. Thesis, Delft University of Technology, 1998.
4. H.A. Liebhafsky, E.J. Cairns, Fuel Cells and Fuel Batteries, Wiley, New York, 1968.
5. Networked solid oxide fuel cell stacks combined with a gas turbine cycle10.1016/S0378-7753(01)01051-5 ↗
6. Numerical analyses of the internal condition of a molten carbonate fuel cell stack: comparison of stack performances for various gas flow types10.1016/S0378-7753(97)02727-4 ↗
7. Y. Mugikura, H. Morita, M. Yoshikawa, T. Watanabe, Modification of cathode performance equation and reaction mechanism of MCFC, in: Proceeding of the 7th FCDIC Fuel Cell Symposium, Tokyo, Japan, 2000.
8. S.F. Au, S.J. McPhail, N. Woudstra, K. Hemmes, The influence of operating temperature on the efficiency of a combined heat and power fuel cell plant, J. Power Sources 122 (2003) 37–46.10.1016/S0378-7753(03)00345-8 ↗
9. Cycle-Tempo version 4.42, Delft University of Technology, Section Thermal Power Engineering TNO Environment, Energy and Process Innovation, 2000, http://www-pe.wbmt.tudelft.nl/ev/cycle/cycle.html.
10. S.F. Au, N. Woudstra, K. Hemmes, I. Uchida, Verification of a simple numerical model in a flowsheeting program by performance testing at a 110 cm2 molten carbonate fuel cell, Energy Conv. Manage., in press.10.1016/S0196-8904(02)00253-4 ↗
11. J.G. Wimer, M.C. Williams, Molten Carbonate Fuel Cell Networks: Principles, Analysis, and Performance, Springfield, NTIS, 1993.10.2172/10177322 ↗
12. T. Ogawa, A. Matsunaga, T. Matsuyama, H. Kasai, K. Miyazawa, Evaluation of 250 kW MCFC stack for 1000 kW MCFC Power plant, Abstracts of the Fuel Cell Seminar, 2000.
13. Y. Izaki, H. Yasue, Demonstration of the first 1000 kW MCFC power plant in Japan, Abstracts of the Fuel Cell Seminar, 2000.