journal article·2007-11

Molten carbonate fuel cell operation with dual fuel flexibility

Joseph Daly, George Steinfeld, David K. Moyer, Franklin H. Holcomb

Journal of Power Sources· Volume 173· Issue 2
Publisher page

Abstract

Abstract The ability to operate highly efficient, pollution-free, distributed-generation power plants on either natural gas or HD-5 grade propane is of interest to the U.S. Army and the U.S. Department of Homeland Security as secure power for critical power operations. To address this interest, Concurrent Technologies Corporation (CTC) teamed with FuelCell Energy (FCE) to test an internally reforming 250 kW carbonate fuel cell using HD-5 propane. This fuel cell power plant, originally designed to operate on pipeline natural gas or digester gas, was modified for dual fuel operation (natural gas and propane). Fuel cell operation using HD-5 propane was demonstrated for over 3900 h and achieved high-electrical efficiency (45.7–47.1% lower heating value (LHV)) over a broad range of power outputs. In addition, instantaneous and on-load fuel switching from natural gas to propane and back was demonstrated without loss of power. This dual fuel power plant operates efficiently on either fuel and provides the U.S. Army and other power users with a viable technology solution for critical power operations.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Fuel Cells and Related Materials · Advancements in Solid Oxide Fuel Cells · Electrocatalysts for Energy Conversion

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (15)

Show source-provided references
1. Appleby · Aerosp. Electron. Syst. Mag. IEEE · 1991 · 6 · 4910.1109/62.121939 ↗
2. Army Energy and Water Campaign Plan for Installations, Department of the Army, August 2006, p. 52. http://army-energy.hqda.pentagon.mil/docs/campaign_plan_01_08_06.pdf.
3. Varbanov · J. Fuel Cell Sci. Technol. · 2006 · 3 · 37510.1115/1.2349515 ↗
4. Fuel Cell Energy DFC300A Fuel Cell Combined Heat and Power Test Report. Submitted to the U.S. Army Engineer Research and Development Center, Construction Engineering Research Laboratory by Concurrent Technologies Corporation, December 2, 2005.
5. Final Technical Progress Report, submitted to U.S. Department of Energy National Energy Technology Laboratory, Submitted by FuelCell Energy Inc., March 2005.
6. D. Brdar, C. Bentley, M. Farooque, P. Oei,T. Rauseo. 2006 Fuel Cell Seminar, Abstract 84, November 16, 2006.
7. Peltier · Power · 2006 · 150
8. US DOE/NETL · 2000
9. Brdar · Fuel Cell Rev. · 2005 · 2
10. Farooque · J. Power Sources · 2006 · 160 · 82710.1016/j.jpowsour.2006.04.127 ↗
11. ASTM D 1835, Standard Specification for Liquefied Petroleum (LP) Gases, ASTM International, West Conshohocken, PA, USA.
12. Wang · Chem. Eng. J. · 2007 · 129 · 1110.1016/j.cej.2006.10.027 ↗
13. Brown · Int. J. Hydrogen Energy · 2001 · 26 · 38110.1016/S0360-3199(00)00092-6 ↗
14. Fuel Cell Power Systems, Performance Test Codes (ASME PTC 50-2002), The American Society of Mechanical Engineers, Three Park Avenue, New York, NY, November 29, 2002.
15. Final Report, prepared for U.S. EPA by King County and CH2MHill, April 2007.