Enhanced performance of VRLA batteries with a novel spirally-wound electrode design
Source abstract
Abstract
A spirally-wound electrode has been designed, constructed and applied to VRLA cells. Because of its unique construction: high strength, light-weight lead-coated glass fibre mesh as the grid, comparatively thin plates and sufficient internal compression, this new design provides significant advantages over the conventional prismatic type of VRLA battery. The total weight of grids and top lead used in a battery can be reduced by 40% compared with conventional cast grids. There was no positive active-material softening and expansion until after over 300 deep cycles. Substantial improvement in sustaining the cycleability has been achieved. This technique also provides a convenient process for manufacturing a spirally-wound VRLA battery in a simple and cost competitive way.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Advanced Battery Technologies Research · Advancements in Battery Materials · ZnO doping and properties
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (8)
Show source-provided references
1. Moseley · J. Power sources · 1997 · 67 · 11510.1016/S0378-7753(97)02503-2 ↗
2. Moseley · J. Power sources · 1998 · 73 · 122010.1016/S0378-7753(98)00029-9 ↗
3. R.D. Prengaman, in: Proceedings of the Thirteenth Annual Battery Conference on Applications and Advances, Long Beach, CA, 13–16 January 1998, p. 199.10.1109/BCAA.1998.653866 ↗
4. Meissner · J. Power Sources · 1999 · 78 · 9910.1016/S0378-7753(99)00019-1 ↗
5. Pavlov · J. Power Sources · 2000 · 87 · 3910.1016/S0378-7753(99)00358-4 ↗
6. Landfors · J. Power Sources · 1994 · 52 · 9910.1016/0378-7753(94)01944-4 ↗
7. Juergens · J. Power Sources · 1995 · 53 · 20110.1016/0378-7753(94)01993-6 ↗
8. Patents CN02203242, CN02203241.