journal article·2002-03

Study of the interface nickel/composite cathode of industrially made Li/V2O5 polymer (POE) batteries working at 90 °C

Pascal André, Philippe Deniard, Raymond Brec, Stéphane Lascaud

Journal of Power Sources· Volume 105· Issue 1
Publisher page

Abstract

Abstract ωLi/V 2 O 5 spirally wound polymer (POE) batteries functioning at 90 °C presented an important capacity fading ca. 20th cycle. This behavior could arise from the cathode material itself, including its in situ formation during the first reduction step from αLi/V 2 O 5 , or from a technical problem linked either to the composite cathode or one of the other cell components. In this paper, after rejection of the two first hypothesis, we clearly demonstrate the negative role of the nickel foil used as cathodic collector.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Advancements in Battery Materials · Advanced Battery Materials and Technologies · Advanced Battery Technologies Research

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (6)

Show source-provided references
1. P. André, P. Deniard, R. Brec, Solid State Sci., 2001, in press.
2. Maingot · Mater. Sci. Forum · 1994 · 152/153 · 29710.4028/www.scientific.net/MSF.152-153.297 ↗
3. Rietveld · J. Appl. Crystallogr. · 1962 · 2 · 6510.1107/S0021889869006558 ↗
4. A.C. Larson, R.B. von Dreele, Generalized structure analysis system (GSAS), Los Alamos National Laboratory Report no. LA-UR-86-748.
5. C. Mouget, Y. Chabre, MacPile, Licensed from CNRS and UJP Grenoble to Bio-Logic, 1, Av. de l’Europe, 38640 Claix, France.
6. Delmas · Solid State Ionics · 1991 · 34 · 113