Equivalent circuit elements for PSpice simulation of PEM stacks at pulse load
Source abstract
Abstract
Abstract The PEFC stack in a commercial power system was operated with room air and pure hydrogen. After the system reached a steady temperature, an ac impedance test was conducted on the fuel cell power system. The impedance data were real-time response generated by the ac sinusoidal excitation. Data for a single PEM stack and PEM stacks operating in parallel and series were collected with or without an embedded system controller board and electronic devices. The equivalent circuit model with three time constants and the non-linear least square fitting program (NLLS) were applied for fitting the stack impedance spectrum. The Levenberg–Marquardt algorithm utilized in the NLLS fitting process automatically adjusted the parameter values of the physical elements in the model to find the best fit result. From the preliminary results, data interpretation and the equivalent circuit model identified the physical elements, the related electrochemical processes, and the phenomenon inside the fuel cells or stacks. Losses from ohmic conduction, anode activation, cathode activation, and mass transfer were separated and analyzed. Further PSpice simulation curves using these equivalent circuit elements demonstrate good agreement with the pulse testing data measured from the PEFC power system.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Fuel Cells and Related Materials · Electrochemical Analysis and Applications · Analytical Chemistry and Sensors
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (27)
Show source-provided references
1. Wagner · 2005
2. Ahn · J. Electrochem. Soc. · 1995 · 142 · 416910.1149/1.2048480 ↗
3. Eikerling · J. Electroanal. Chem. · 1999 · 107 · 475
4. Makharia · J. Electrochem. Soc. · 2005 · 152 · A97010.1149/1.1888367 ↗
5. Selman · Electrochim. Acta · 1993 · 38 · 206310.1016/0013-4686(93)80341-V ↗
6. Holz · J. Electrochem. Soc. · 1984 · 131 · 229810.1149/1.2115244 ↗
7. Springer · 1999
8. Diard · J. Electrochem. Soc. · 2004 · 151 · A219310.1149/1.1815152 ↗
9. Wagner · J. Appl. Electrochem. · 2002 · 32 · 85910.1023/A:1020551609230 ↗
10. Wilkinson · 2003 · 611
11. Yuan · J. Power Sources · 2006 · 161 · 92010.1016/j.jpowsour.2006.05.003 ↗
12. Kuhn · Electrochim. Acta · 2006 · 51 · 162210.1016/j.electacta.2005.02.108 ↗
13. R.S. Rodgers, Research Solutions & Resources, 2005, http://www.consultrsr.com/resources/eis/index.htm.
14. Boukamp · Solid State Ionics · 1986 · 18/19 · 13610.1016/0167-2738(86)90100-1 ↗
15. González-Cuenca · Fuel Cells · 2001 · 1 · 25610.1002/1615-6854(200112)1:3/4<256::AID-FUCE256>3.0.CO;2-I ↗
16. Bard · 1998
17. Gamry Instruments, Gamry Echem Analyst Software—“Porous Bounded Warburg”, 2007.
18. Gamry Instruments, Electrochemical Impedance Spectroscopy Primer, Warminster, PA, 2007, p. 6.
19. V.D. Jovic, Determination of the correct value of Cdl from the impedance results fitted by the commercially available software, http://www.gamry.com, Warminster, PA, 2003.
20. Ballard Power Systems, Nexa Power Module Installation Manual. British Columbia, Canada, 2002, pp. 1–49.
21. Gamry Instruments, FC350™ Fuel Cell Monitor. Warminster, PA, 2002, pp. 1–4.
22. Zhu · J. Power Sources · 2004 · 128 · 23110.1016/j.jpowsour.2003.09.074 ↗
23. Costamagna · J. Power Sources · 2001 · 102 · 242.10.1016/S0378-7753(01)00807-2 ↗
24. Wagner · Electrochim. Acta · 1998 · 43 · 378510.1016/S0013-4686(98)00138-8 ↗
25. Zhu · J. Power Sources · 2007 · 168 · 21110.1016/j.jpowsour.2007.02.071 ↗
26. Wikipedia Encyclopedia, Wikimedia Foundation Inc., 2007, http://en.wikipedia.org/wiki/PSPICE, http://en.wikipedia.org/wiki/SPICE.
27. PSpice Simulation, Cadence Design Systems, San Jose, CA, 2007, http://www.cadence.com/products/orcad/pspice_a_d/index.aspx.