journal article·2017-10Open access

Stall/surge dynamics of a multi-stage air compressor in response to a load transient of a hybrid solid oxide fuel cell-gas turbine system

Mohammad Ali Azizi, Jacob Brouwer

Abstract

Abstract A better understanding of turbulent unsteady flows in gas turbine systems is necessary to design and control compressors for hybrid fuel cell-gas turbine systems. Compressor stall/surge analysis for a 4 MW hybrid solid oxide fuel cell-gas turbine system for locomotive applications is performed based upon a 1.7 MW multi-stage air compressor. Control strategies are applied to prevent operation of the hybrid SOFC-GT beyond the stall/surge lines of the compressor. Computational fluid dynamics tools are used to simulate the flow distribution and instabilities near the stall/surge line. The results show that a 1.7 MW system compressor like that of a Kawasaki gas turbine is an appropriate choice among the industrial compressors to be used in a 4 MW locomotive SOFC-GT with topping cycle design. The multi-stage radial design of the compressor enhances the ability of the compressor to maintain air flow rate during transient step-load changes. These transient step-load changes are exhibited in many potential applications for SOFC/GT systems. The compressor provides sustained air flow rate during the mild stall/surge event that occurs due to the transient step-load change that is applied, indicating that this type of compressor is well-suited for this hybrid application.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Advancements in Solid Oxide Fuel Cells · Catalysis and Oxidation Reactions · Catalytic Processes in Materials Science

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (40)

Show source-provided references
1. Feasibility study for SOFC-GT hybrid locomotive power: Part I. Development of a dynamic 3.5 MW SOFC-GT FORTRAN model10.1016/j.jpowsour.2012.04.024 ↗
2. Feasibility study for SOFC-GT hybrid locomotive power part II. System packaging and operating route simulation10.1016/j.jpowsour.2012.04.023 ↗
3. Solid oxide fuel cells for stationary, mobile, and military applications10.1016/S0167-2738(02)00349-1 ↗
4. Fuel cell/gas turbine hybrid10.1016/B978-044452745-5.00911-4 ↗
5. Part load operation of SOFC/GT hybrid systems: stationary analysis10.1016/j.ijhydene.2012.08.015 ↗
6. 2002
7. Introduction to Stationary Fuel Cells Solid oxide fuel cells: from materials to system modeling
8. Analytical investigation of high temperature 1kW solid oxide fuel cell system feasibility in methane hydrate recovery and deep ocean power generation10.1016/j.apenergy.2016.06.119 ↗
9. Multi-fuel capability of solid oxide fuel cells10.1007/s10832-004-5174-z ↗
10. Direct JP-8 conversion using a liquid tin anode solid oxide fuel cell (LTA-SOFC) for military applications10.1115/1.3005589 ↗
11. Cannock landfill gas powering a small tubular solid oxide fuel cell—a case study10.1016/S0378-7753(99)00417-6 ↗
12. On-board diesel fuel processing for an SOFC–APU—technical challenges for catalysis and reactor design10.1016/j.apcatb.2006.02.025 ↗
13. O'Hayre · 2006
14. Hybrid fuel-cell strategies for clean power generation10.1109/TIA.2005.847293 ↗
15. A review of integration strategies for solid oxide fuel cells10.1016/j.jpowsour.2009.07.045 ↗
16. General fuel cell hybrid synergies and hybrid system testing status10.1016/j.jpowsour.2005.09.070 ↗
17. Power plant system configurations for the 21st century
18. Enhanced coal gasification heated by unmixed combustion integrated with an hybrid system of SOFC/GT
19. Thermodynamic analysis and optimization of IT-SOFC-based integrated coal gasification fuel cell power plants10.1115/1.4003018 ↗
20. Jacob Brouwer. Hybrid Gas Turbine Fuel Cell Systems Handbook, National Energy Technology Laboratory.
21. Sue Fuhs, Solid Oxide Fuel Cells & Hybrid, GE Hybrid Power Generation Systems.
22. Dustin Fogle McLarty · 2010
23. Evaluation of hybrid fuel cell turbine system startup with compressor bleed
24. Hybrid simulation facility based on commercial 100 kWe micro gas turbine10.1115/1.3006200 ↗
25. Hybrid system test rig: start-up and shutdown physical emulation10.1115/1.3176663 ↗
26. Fuel cell–gas turbine hybrid system design part I: steady state performance10.1016/j.jpowsour.2013.11.122 ↗
27. Fuel cell–gas turbine hybrid system design part II: dynamics and control.'' Journal of Power Sources
28. Control strategy for a solid oxide fuel cell and gas turbine hybrid system10.1016/j.jpowsour.2005.09.010 ↗
29. Development of controls for dynamic operation of carbonate fuel cell-gas turbine hybrid systems
30. Steady state analysis of a sofc/gt hybrid power plant test rig
31. Sensitivity analysis of transient compressor operation behaviour in SOFC-GT hybrid systems
32. Steady-state and transient compressor surge behavior within a SOFC-GT-hybrid system
33. Experimental test facility for the analysis of transient behavior of high temperature fuel cell/gas turbine hybrid power plants10.1115/1.2217954 ↗
34. Gas turbine components optimised for use in hybrid SOFC-GT systems
35. Dustin Fogle McLarty · 2013
36. Transient analysis of 220 kW solid oxide fuel cell-gas turbine hybrid system using computational fluid dynamics results10.1149/07101.0289ecst ↗
37. Experimental and theoretical evidence for control requirements in solid oxide fuel cell gas turbine hybrid systems10.1016/j.jpowsour.2012.02.102 ↗
38. Kawasaki gas turbines-americas gas turbines power generation Technol. Appl.. A Present. by Kawasaki Gas Turbines, pp. 1-45.
39. ANSYS® Academic Research, Release 16.0.
40. Two-equation eddy-viscosity turbulence models for engineering applications10.2514/3.12149 ↗