Influence of measurement procedure on quality of impedance spectra on lead–acid batteries
Source abstract
Abstract
Abstract Many battery simulation models, but also electrochemical interpretations are based on impedance spectroscopy. However, the impedance of a battery is influenced by various factors, e.g. in the case of a lead–acid battery: state of charge (SOC), charging or discharging, superimposed dc current, short-term history or homogeneity of the electrolyte. This paper analyses the impact of those factors on impedance spectra of lead–acid batteries. The results show that very detailed information about the conditions during the measurement is crucial for the correct interpretation of a spectrum.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Advanced Battery Technologies Research · Advancements in Battery Materials · Conducting polymers and applications
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (24)
Show source-provided references
1. Andersson · J. Appl. Electrochem. · 2001 · 31 · 110.1023/A:1004105622558 ↗
2. Barsoukov · 2005
3. M. Bragard, Aufbau und Inbetriebnahme eines Elektrometer-Vorverstärkers, Student Research Project, Institute for Power Electronics and Electrical Drives ISEA, RWTH Aachen University, 2005.
4. S. Buller, Impedance-based simulation models for energy storage devices in advanced automotive power systems, PhD thesis, Institute for Power Electronics and Electrical Drives ISEA, RWTH Aachen University, 2002.
5. Buller · J. Power Sources · 2003 · 113 · 42210.1016/S0378-7753(02)00558-X ↗
6. B. Fricke, T. Sanders, EISmeter Manual, Institute for Power Electronics and Electrical Drives ISEA, RWTH Aachen University, 2003.
7. Gaskatel Gesellschaft fuer Gassysteme durch Katalyse und Elektrochemie mbH, Germany, Reference Electrode, http://www.gaskatel.de/english/hydroflex/, September 2010.
8. Karden · J. Power Sources · 2000 · 85 · 7210.1016/S0378-7753(99)00385-7 ↗
9. E. Karden, Using low-frequency impedance spectroscopy for characterisation, monitoring and modeling of industrial batteries, PhD thesis, RWTH Aachen University, Institute for Power Electronics and Electrical Drives ISEA, 2001, ISBN 3-8265-9766-4.
10. Karden · J. Power Sources · 2007 · 168 · 210.1016/j.jpowsour.2006.10.090 ↗
11. Kirchev · J. Power Sources · 2007 · 170 · 49510.1016/j.jpowsour.2007.03.045 ↗
12. Kirchev · J. Power Sources · 2008 · 179 · 80810.1016/j.jpowsour.2007.12.015 ↗
13. Kirchev · J. Power Sources · 2009 · 191 · 8210.1016/j.jpowsour.2008.10.098 ↗
14. Kowal · J. Power Sources · 2009 · 191 · 4210.1016/j.jpowsour.2008.12.016 ↗
15. Kowal · IEEE Trans. Instrum. Meas. · 2009 · 58 · 234310.1109/TIM.2009.2013927 ↗
16. J. Kowal, Spatially resolved impedance of nonlinear inhomogeneous devices – using the example of lead-acid batteries, PhD thesis, RWTH Aachen University, Institute for Power Electronics and Electrical Drives ISEA, 2010, ISBN 978-3-8322-9483-0.
17. Pavlov · J. Power Sources · 2010 · 195 · 444410.1016/j.jpowsour.2009.12.132 ↗
18. Schaeck · J. Power Sources · 2011 · 196 · 154110.1016/j.jpowsour.2010.08.077 ↗
19. C.A. Schiller, W. Strunz, Impedanzmessung – Sein oder Schein, in Technische Mitteilungen, vol. 99, 1. Symposium Impedanzspektroskopie, Haus der Technik, Essen, May 2006, 12–18, ISSN 0040-1439
20. C.A. Schiller, W. Strunz, Impedanzmessungen an Systemen mit merklicher zeitlicher Drift, in Technische Mitteilungen, 99, 1. Symposium Impedanzspektroskopie, Haus der Technik, Essen, May 2006, 107–111, ISSN 0040-1439
21. M. Thele, A contribution to the modelling of the charge acceptance of lead-acid batteries – using frequency and time domain based concepts, PhD thesis, RWTH Aachen University, Germany, Institute for Power Electronics and Electrical Drives ISEA, 2008.
22. Thele · J. Power Sources · 2007 · 168 · 3110.1016/j.jpowsour.2006.11.088 ↗
23. Urquidi-Macdonald · J. Electrochem. Soc. · 1986 · 133 · 201810.1149/1.2108332 ↗
24. Urquidi-Macdonald · Electrochim. Acta · 1990 · 35 · 155910.1016/0013-4686(90)80010-L ↗