Online monitoring of fuel starvation and water management in an operating polymer electrolyte membrane fuel cell by a novel diagnostic tool based on total harmonic distortion analysis
Source abstract
Abstract
Abstract The present study deals with a novel diagnostic tool for fuel and water management problems by analyzing the harmonics on an operating polymer electrolyte membrane fuel cell. In this method, a low frequency signal is applied to the fuel cell and the total harmonic distortion contained in the resulting signal is observed under different conditions. The total harmonic distortion is used to monitor and identify the conditions online such as anode drying, anode flooding, hydrogen starvation and cathode flooding prevailing in the cell. This is done by identifying a set of indicator frequencies correspond to the aforementioned critical conditions. Through empirical studies, it is shown that frequency responses lead to a high total harmonic distortion value indicating critical conditions and provide an accurate diagnostic method to detect an even slightly degraded state. These results successfully demonstrate the promise of the proposed method in overcoming performance losses by efficient online monitoring of fuel cells. The relation between the health of the fuel cell and the variations in the harmonics present in the studied signal is characterized and utilized for the diagnostic studies of polymer electrolyte membrane fuel cell.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Fuel Cells and Related Materials · Advanced Battery Technologies Research · Electrocatalysts for Energy Conversion
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (32)
Show source-provided references
1. A review of polymer electrolyte membrane fuel cells: technology, applications, and needs on fundamental research10.1016/j.apenergy.2010.09.030 ↗
2. An overview of fuel cell technology: fundamentals and applications10.1016/j.rser.2014.01.012 ↗
3. Recent advances and challenges of fuel cell based power system architectures and control – a review10.1016/j.rser.2017.01.148 ↗
4. Batteries and fuel cells for emerging electric vehicle markets10.1038/s41560-018-0108-1 ↗
5. Fuel cell degradation and failure analysis
6. Compilation of factors affecting durability of proton exchange membrane fuel cell (PEMFC)
7. A review of durability test protocols of the proton exchange membrane fuel cells for vehicle10.1016/j.apenergy.2018.04.050 ↗
8. A review of automotive proton exchange membrane fuel cell degradation under start-stop operating condition10.1016/j.apenergy.2018.04.049 ↗
9. Diagnostic tools in PEM fuel cell research: Part I Electrochemical techniques10.1016/j.ijhydene.2008.01.013 ↗
10. Diagnostic tools in PEM fuel cell research: Part IIPhysical/chemical methods10.1016/j.ijhydene.2008.01.020 ↗
11. A review on model-based diagnosis methodologies for PEMFCs10.1016/j.ijhydene.2013.03.106 ↗
12. Diagnostic tools for PEMFCs: from conception to implementation10.1016/j.ijhydene.2014.04.163 ↗
13. A review on non-model based diagnosis methodologies for PEM fuel cell stacks and systems10.1016/j.ijhydene.2013.04.007 ↗
14. Total harmonic distortion based method for linearity assessment in electrochemical systems in the context of EIS10.1016/j.electacta.2015.10.152 ↗
15. On-line performance monitoring of PEM fuel cell using a fast EIS approach
16. FPGA implementation of the EIS technique for the on-line diagnosis of fuel-cell systems
17. Abraham · 2017
18. Polymer electrolyte fuel cells 14 (PEFC 14)
19. PEM fuel cell testing by electrochemical impedance spectroscopy, Electr10.1016/j.epsr.2008.05.012 ↗
20. Development of new test instruments and protocols for the diagnostic of fuel cell stacks10.1016/j.jpowsour.2010.08.029 ↗
21. Ramschak · 2009
22. Detection of fuel cell critical status by stack voltage analysis10.1016/j.jpowsour.2006.01.009 ↗
23. Total harmonic distortion analysis of oxygen reduction reaction in proton exchange membrane fuel cells10.1016/j.electacta.2013.03.194 ↗
24. Total harmonic distortion analysis for direct methanol fuel cell anode10.1016/j.elecom.2010.08.022 ↗
25. Sensing methanol concentration in direct methanol fuel cell with total harmonic distortion: theory and application10.1016/j.electacta.2012.02.018 ↗
26. Online health monitoring of a fuel cell using total harmonic distortion analysis10.1016/j.ijhydene.2013.12.180 ↗
27. Initial conditioning of Polymer Eelectrolyte Membrane fuel cell by temperature and potential cycling10.17344/acsi.2014.730 ↗
28. Block co-polymer templated mesoporous carbon–Nafion hybrid membranes for polymer electrolyte fuel cells under reduced relative humidity10.1016/j.memsci.2015.11.011 ↗
29. Sulfonated graphene–nafion composite membranes for polymer electrolyte fuel cells operating under reduced relative humidity10.1021/acs.jpcc.5b11674 ↗
30. System integration, durability and reliability of fuel cells: challenges and solutions10.1016/j.apenergy.2016.12.083 ↗
31. A sol-gel modified alternative nafion-silica composite membrane for polymer electrolyte fuel cells10.1149/1.2401031 ↗
32. Uncovering Nafion-multiwalled carbon nanotube hybrid membrane for prospective polymer electrolyte membrane fuel cell under low humidity10.1016/j.memsci.2018.05.051 ↗