journal article·2006-11

Model-based condition monitoring of PEM fuel cell using Hotelling T2 control limit

X. Xue, J. Tang, N. Sammes, Y. Ding

Journal of Power Sources· Volume 162· Issue 1
Publisher page

Abstract

Although a variety of design and control strategies have been proposed to improve the performance of polymer electrolyte membrane (PEM) fuel cell systems, temporary faults in such systems still might occur during operations due to the complexity of the physical process and the functional limitations of some components. The development of an effective condition monitoring system that can detect these faults in a timely manner is complicated by the operating condition variation, the significant variability/uncertainty of the fuel cell system, and the measurement noise. In this research, we propose a model-based condition monitoring scheme that employs the Hotelling T2 statistical analysis for fault detection of PEM fuel cells. Under a given operating condition, the instantaneous load current, the temperature and fuel/gas source pressures of the fuel cell are measured. These measurements are then fed into a lumped parameter dynamic fuel cell model for the establishment of the baseline under the same operating condition for comparison. The fuel cell operation is simulated under statistical sampling of parametric uncertainties with specified statistics (mean and variance) that account for the system variability/uncertainty and measurement noise. This yields a group of output voltages (under the same operating condition but with uncertainties) as the baseline. Fault detection is facilitated by comparing the real-time measurement of the fuel cell output voltage with the baseline voltages by employing the Hotelling T2 statistical analysis. The baseline voltages are used to evaluate the output T2 statistics under normal operating condition. Then, with a given confidence level the upper control limit can be specified. Fault condition will be declared if the T2 statistics of real-time voltage measurement exceeds the upper control limit. This model-based robust condition monitoring scheme can deal with the operating condition variation, various uncertainties in a fuel cell system, and measurement noise. Our analysis indicates that this scheme has very high detection sensitivity and can detect the fault conditions at the early stage.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Fuel Cells and Related Materials · Advanced Battery Technologies Research · Electrocatalysts for Energy Conversion

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (25)

Show source-provided references
1. A water and heat management model for proton-exchange-membrane fuel cells10.1149/1.2220792 ↗
2. polymer electrolyte fuel cell model10.1149/1.2085971 ↗
3. Modeling and experimental diagnostics in polymer electrolyte fuel cells10.1149/1.2221120 ↗
4. Operational aspects of a large PEFC stack under practical conditions10.1016/j.jpowsour.2003.09.060 ↗
5. Anode water removal: a water management and diagnostic technique for solid polymer fuel cells10.1016/0013-4686(94)00266-4 ↗
6. Effect of direct liquid water injection and interdigitated flow field on the performance of proton exchange membrane fuel cells10.1016/S0013-4686(98)00139-X ↗
7. A liquid water management strategy for PEM fuel cell stacks10.1016/S0378-7753(02)00591-8 ↗
8. Control of miniature proton exchange membrane fuel cells based on fuzzy logic10.1016/j.jpowsour.2003.10.010 ↗
9. Diagnosis of automotive fuel cell power generators10.1016/j.jpowsour.2003.10.001 ↗
10. Seber · 1984
11. Decomposition of T2 for multivariate control chart interpretation10.1080/00224065.1995.11979573 ↗
12. Automatic feature extraction of waveform signals for in-process diagnostic performance improvement10.1023/A:1011248925750 ↗
13. A model predicting transient response of proton exchange membrane fuel cells10.1016/S0378-7753(96)02360-9 ↗
14. PEM fuel cell dynamic model with phase change effect10.1115/1.2041670 ↗
15. Three-dimensional analysis of transport and electrochemical reactions in polymer electrolyte fuel cells10.1016/j.jpowsour.2003.07.007 ↗
16. Control-oriented modeling and analysis for automotive fuel cell systems10.1115/1.1648308 ↗
17. Transport phenomena analysis in proton exchange membrane fuel cells10.1115/1.2098830 ↗
18. Two-phase flow and transport in the air cathode of proton exchange membrane fuel cells10.1016/S0378-7753(00)00662-5 ↗
19. A two-phase flow and transport model for the cathode of PEM fuel cells10.1016/S0017-9310(01)00322-2 ↗
20. Numerical predication of mass-exchange between cathode and anode channels in a PEM fuel cell10.1016/S0017-9310(00)00257-X ↗
21. Saltelli · 2000
22. Robust wave function optimization procedures in quantum Monte Carlo methods10.1063/1.1455618 ↗
23. A comparison of three methods for selecting values of input variables in the analysis of output from a computer code10.2307/1268522 ↗
24. Latin hypercube sampling of Gaussian random fields10.2307/1271347 ↗
25. An efficient sampling technique for off-line quality control10.2307/1271135 ↗