journal article·2021-12

A self-powered glucose biosensor device based on microfluidics using human blood

Ricardo A. Escalona-Villalpando, A. Sandoval-García, J. Roberto Espinosa L., M.G. Miranda-Silva, L.G. Arriaga, Shelley D. Minteer, J. Ledesma-García

Publisher page

Abstract

Abstract A self-powered glucose biosensor (SPGB) was developed based on biofuel cells (BFCs)and a microfluidic system as a suitable technology for high potential application in clinical diagnosis. In this work, a bioanode and biocathode were assembled by glucose oxidase-based and laccase-based electrodes, respectively, which were incorporated into a microfluidic system (m-SPGB), while the anolyte and catholyte were phosphate buffered at different pH values of 7.4 and 5.6, respectively. The m-SPGB showed a linear dynamic interval of 0–10 mM (R2 = 0.9907), a low limit of detection of 0.48 mM and a response to interfering species. Subsequently, human blood was used in the anolyte to quantify glucose molecules in real samples, obtaining a low relative error percentage when compared with a commercial glucometer. The coupling of the m-SPGB with a wireless electronic device allowed the detection and processing of the signal in the quantification of glucose directly without using a potentiostat/galvanostat. The promising results of the m-SPGB connected to a Wi-Fi electronic device are well suited for clinical application.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Electrochemical sensors and biosensors · Advanced biosensing and bioanalysis techniques · Neuroscience and Neural Engineering

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (60)

Show source-provided references
1. Obstructive sleep apnoea in people with Type 1 diabetes: prevalence and association with micro- and macrovascular complications10.1111/dme.12582 ↗
2. Polyaniline-based glucose biosensor: a review10.1016/j.jelechem.2016.10.033 ↗
3. The technology tree in the design of glucose biosensors10.1016/j.trac.2019.115642 ↗
4. Self-powered sensors10.1007/s00216-011-4782-0 ↗
5. Single glucose biofuel cells implanted in rats power electronic devices10.1038/srep01516 ↗
6. Self-powered enzyme-based biosensors10.1021/ja0167102 ↗
7. A self-powered biosensing device with an integrated hybrid biofuel cell for intermittent monitoring of analytes10.1016/j.bios.2017.11.045 ↗
8. Self-powering amperometric sensor and biosensor10.1016/j.jelechem.2012.02.017 ↗
9. Cholesterol self-powered biosensor10.1021/ac501699p ↗
10. Self-powered sensor for trace Hg2+ detection10.1021/ac2001884 ↗
11. Biofuel cell based self-powered sensing platform for l-cysteine detection10.1021/ac504694z ↗
12. Fabrication of surface protein-imprinted biofuel cell for sensitive self-powered glycoprotein detection10.1021/acsami.6b12010 ↗
13. Nitroaromatic actuation of mitochondrial bioelectrocatalysis for self-powered explosive sensors10.1021/ja807250b ↗
14. A self-powered origami paper analytical device with a pop-up structure for dual-mode electrochemical sensing of ATP assisted by glucose oxidase-triggered reaction10.1016/j.bios.2019.111839 ↗
15. Light-driven self-powered biosensor for ultrasensitive organophosphate pesticide detection via integration of the conjugated polymer-sensitized CdS and enzyme inhibition strategy10.1039/C8TB02286K ↗
16. Enzymes as working or inspirational electrocatalysts for fuel cells and electrolysis10.1021/cr0680639 ↗
17. Biofuel cell based on anode and cathode modified by glucose oxidase10.1002/elan.201300482 ↗
18. Self-powered biosensors10.1021/acssensors.7b00818 ↗
19. Improving the performance of lactate/oxygen biofuel cells using a microfluidic design10.1016/j.jpowsour.2016.12.082 ↗
20. Evaluation of hybrid and enzymatic nanofluidic fuel cells using 3D carbon structures10.1016/j.ijhydene.2018.04.016 ↗
21. Integrated printed microfluidic biosensors10.1016/j.tibtech.2019.03.009 ↗
22. Enzymatic fuel cells in a microfluidic environment: status and opportunities. A mini review10.1016/j.elecom.2019.106533 ↗
23. Intervention of microfluidics in biofuel and bioenergy sectors: technological considerations and future prospects10.1016/j.rser.2018.11.040 ↗
24. Isolation and purification of PQQ-dependent lactate dehydrogenase from Gluconobacter and use for direct electron transfer at carbon and gold electrodes10.1016/j.bioelechem.2008.07.005 ↗
25. Employing FAD-dependent glucose dehydrogenase within a glucose/oxygen enzymatic fuel cell operating in human serum10.1016/j.bioelechem.2015.04.005 ↗
26. Anthracene-modified multi-walled carbon nanotubes as direct electron transfer scaffolds for enzymatic oxygen reduction10.1021/cs200475q ↗
27. Improving the performance of lactate/oxygen biofuel cells using a microfluidic design10.1016/j.jpowsour.2016.12.082 ↗
28. Promiscuous glucose oxidase: electrical energy conversion of multiple polysaccharides spanning starch and dairy milk10.1021/acscatal.5b01777 ↗
29. Stability of carbon nanotube yarn biofuel cell in human body fluid10.1016/j.jpowsour.2015.03.140 ↗
30. Wearable biofuel cells based on the classification of enzyme for high power outputs and lifetimes10.1016/j.bios.2018.09.086 ↗
31. An enzymatic glucose/O2 biofuel cell operating in human blood10.1016/j.bios.2016.04.016 ↗
32. Perspective use of direct human blood as an energy source in air-breathing hybrid microfluidic fuel cells10.1016/j.jpowsour.2015.04.089 ↗
33. Self-powered electronic-skin for detecting glucose level in body fluid basing on piezo-enzymatic-reaction coupling process10.1016/j.nanoen.2016.05.021 ↗
34. Triboelectric liquid volume sensor for self-powered lab-on-chip applications10.1016/j.nanoen.2016.02.054 ↗
35. A self-powered electronic-skin for real-time perspiration analysis and application in motion state monitoring10.1039/C8TC03296C ↗
36. Hybrid PbS quantum dot/nanoporous NiO film nanostructure: preparation, characterization, and application for a self-powered cathodic photoelectrochemical biosensor10.1021/acs.analchem.7b01557 ↗
37. Integrated self-powered microchip biosensor for endogenous biological cyanide10.1021/ac100274s ↗
38. A glucose/O2 fuel cell-based self-powered biosensor for probing a drug delivery model with self-diagnosis and self-evaluation10.1039/C8SC04019B ↗
39. Enzymatic biofuel cell-based self-powered biosensing of protein kinase activity and inhibition via thiophosphorylation-mediated interface engineering10.1039/C8CC02328J ↗
40. Miniature amperometric self-powered continuous glucose sensor with linear response10.1021/ac300217p ↗
41. A 3D paper-based enzymatic fuel cell for self-powered, low-cost glucose monitoring10.1016/j.bios.2015.12.020 ↗
42. A self-powered glucose biosensing system10.1016/j.bios.2015.11.022 ↗
43. Visible-light induced self-powered sensing platform based on a photofuel cell10.1021/acs.analchem.6b01600 ↗
44. A highly flexible self-powered biosensor for glucose detection by epitaxial deposition of gold nanoparticles on conductive bacterial cellulose10.1016/j.cej.2018.06.098 ↗
45. Coupling of an enzymatic biofuel cell to an electrochemical cell for self-powered glucose sensing with optical readout10.1016/j.bioelechem.2015.04.003 ↗
46. Microneedle-based self-powered glucose sensor10.1016/j.elecom.2014.07.014 ↗
47. Highly selective and sensitive self-powered glucose sensor based on capacitor circuit10.1038/s41598-017-01665-9 ↗
48. Sensitive electrochemical detection of glucose via a hybrid self-powered biosensing system10.1016/j.sbsr.2018.08.002 ↗
49. Biofuel cell-based self-powered biogenerators for online continuous monitoring of neurochemicals in rat brain10.1039/C2AN36385B ↗
50. A dual functional analytical device for self-powered point of care testing and electric energy storage10.1039/C5CC01283J ↗
51. A micro-planar amperometric glucose sensor unsusceptible to interference species10.1016/S0925-4005(98)00145-2 ↗
52. Ferrocene-pyrene conjugates for detection of various monovalent anions in solution10.1016/j.aca.2020.02.045 ↗
53. Fabrication of a novel Ferrocene/Thionin bimediator modified electrode for the electrochemical determination of dopamine and hydrogen peroxide10.1016/j.jelechem.2017.08.016 ↗
54. Perspective use of direct human blood as an energy source in air-breathing hybrid microfluidic fuel cells10.1016/j.jpowsour.2015.04.089 ↗
55. Clean energy from human sweat using an enzymatic patch10.1016/j.jpowsour.2018.11.076 ↗
56. BaTiO3 nanoparticles as biomaterial film for self-powered glucose sensor application10.1016/j.snb.2016.05.004 ↗
57. Stretchable biofuel cells as wearable textile-based self-powered sensors10.1039/C6TA08358G ↗
58. A self-powered glucosa biosensing system10.1016/j.bios.2015.11.022 ↗
59. BioCapacitor—a novel category of biosensor10.1016/j.bios.2008.09.014 ↗
60. Simultaneously harvesting mechanical and chemical energies by a hybrid cell for self-powered biosensors and personal electronics10.1039/c3ee40764k ↗