Abstract

Abstract This work presents a flexible and light air-breathing hybrid microfluidic fuel cell (HμFC) operated under biological conditions. A mixture of glucose oxidase, glutaraldehyde, multi-walled carbon nanotubes and vulcan carbon (GOx/VC-MWCNT-GA) was used as the bioanode. Meanwhile, integrating an air-exposed electrode (Pt/C) as the cathode enabled direct oxygen delivery from air. The microfluidic fuel cell performance was evaluated using glucose obtained from three different sources as the fuel: 5 mM glucose in phosphate buffer, human serum and human blood. For the last fuel, an open circuit voltage and maximum power density of 0.52 V and 0.20 mW cm−2 (at 0.38 V) were obtained respectively; meanwhile the maximum current density was 1.1 mA cm−2. Furthermore, the stability of the device was measured in terms of recovery after several polarization curves, showing excellent results. Although this air-breathing HμFC requires technological improvements before being tested in a biomedical device, it represents the best performance to date for a microfluidic fuel cell using human blood as glucose source.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Electrochemical sensors and biosensors · Electrochemical Analysis and Applications · Conducting polymers and applications

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (30)

Show source-provided references
1. Agnès · Electrochem. Commun. · 2013 · 34 · 10510.1016/j.elecom.2013.05.018 ↗
2. Barton · Chem. Rev. · 2004 · 104 · 486710.1021/cr020719k ↗
3. Beneyton · Chem. Comm. · 2013 · 49 · 109410.1039/c2cc37906f ↗
4. Zebda · Electrochim. Acta · 2011 · 56 · 1037810.1016/j.electacta.2011.01.101 ↗
5. Cosnier · Electrochem. Commun. · 2014 · 38 · 1910.1016/j.elecom.2013.09.021 ↗
6. Bankar · Biotechnol. Adv. · 2009 · 27 · 48910.1016/j.biotechadv.2009.04.003 ↗
7. Radisic · Microelectron. Eng. · 2014 · 120 · 25110.1016/j.mee.2013.07.004 ↗
8. Trogadas · Carbon · 2014 · 75 · 510.1016/j.carbon.2014.04.005 ↗
9. Falk · Electrochim. Acta · 2012 · 82 · 19110.1016/j.electacta.2011.12.133 ↗
10. Pan · Adv. Mater. · 2010 · 22 · 538810.1002/adma.201002519 ↗
11. Wang · Biosens. Bioelectron. · 2012 · 31 · 21910.1016/j.bios.2011.10.020 ↗
12. Ammam · Biosens. Bioelectron. · 2010 · 25 · 147410.1016/j.bios.2009.11.001 ↗
13. Gao · Electrochem. Commun. · 2007 · 9 · 98910.1016/j.elecom.2006.12.008 ↗
14. Kim · Phys. Chem. Chem. Phys. · 2013 · 15 · 351010.1039/c3cp00074e ↗
15. Lee · Enzyme Microb. Tech. · 2011 · 48 · 8010.1016/j.enzmictec.2010.09.010 ↗
16. Ammam · Biotechnol. Bioeng. · 2012 · 109 · 160110.1002/bit.24438 ↗
17. Bergmeyer · 1986
18. Moreno-Zuria · J. Power Sourc. · 2014 · 269 · 78310.1016/j.jpowsour.2014.07.049 ↗
19. López-González · Biosens. Bioelectron. · 2014 · 62 · 22110.1016/j.bios.2014.06.054 ↗
20. Coman · Fuel Cells · 2010 · 10 · 910.1002/fuce.200900121 ↗
21. Ugwu · Pharm. Technol. · 2004 · 86
22. Pikal-Cleland · Arch. Biochem. Biophys. · 2000 · 384 · 39810.1006/abbi.2000.2088 ↗
23. Boron · 2005 · 849
24. Dimcheva · Z. fur Naturforsch. C. J. Biosci. · 2002 · 57 · 70510.1515/znc-2002-7-826 ↗
25. Wang · Chem. Rev. · 2008 · 108 · 81410.1021/cr068123a ↗
26. Blaedel · Clin. Chem. · 1975 · 21 · 11910.1093/clinchem/21.1.119 ↗
27. Schmelzeisen-Redeker · J. Diabetes Sci. Tech. · 2013 · 7 · 80810.1177/193229681300700402 ↗
28. Barreau · Diabetes Care · 1988 · 11 · 11610.2337/diacare.11.2.116 ↗
29. Rao · Clin. Chim. Acta · 2005 · 356 · 17810.1016/j.cccn.2005.01.027 ↗
30. Tang · Arch. Pathol. Lab. Med. · 2000 · 124 · 113510.5858/2000-124-1135-EODHLO ↗