journal article·2011-02

Lead-acid batteries in micro-hybrid applications. Part I. Selected key parameters

S. Schaeck, A.O. Stoermer, F. Kaiser, L. Koehler, J. Albers, H. Kabza

Journal of Power Sources· Volume 196· Issue 3
Publisher page

Abstract

Abstract Micro-hybrid electric vehicles were launched by BMW in March 2007. These are equipped with brake energy regeneration (BER) and the automatic start and stop function (ASSF) of the internal combustion engine. These functions are based on common 14 V series components and lead-acid (LA) batteries. The novelty is given by the intelligent onboard energy management, which upgrades the conventional electric system to the micro-hybrid power system (MHPS). In part I of this publication the key factors for the operation of LA batteries in the MHPS are discussed. Especially for BER one is high dynamic charge acceptance (DCA) for effective boost charging. Vehicle rest time is identified as a particular negative parameter for DCA. It can be refreshed by regular fully charging at elevated charge voltage. Thus, the batteries have to be outstandingly robust against overcharge and water loss. This can be accomplished for valve-regulated lead-acid (VRLA) batteries at least if they are mounted in the trunk. ASSF goes along with frequent high-rate loads for warm cranking. The internal resistance determines the drop of the power net voltage during cranking and is preferably low for reasons of power net stability even after years of operation. Investigations have to be done with aged 90 Ah VRLA–absorbent glass mat (AGM) batteries. Battery operation at partial state-of-charge gives a higher risk of deep discharging (overdischarging). Subsequent re-charging then is likely to lead to the formation of micro-short circuits in the absorbent glass mat separator.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Engine and Fuel Emissions · Electric and Hybrid Vehicle Technologies · Advanced Combustion Engine Technologies

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (37)

Show source-provided references
1. Wolff · 2007
2. Hafkemeyer · 2005
3. Schmid · 2007
4. S. Schaeck, Simultaneous engineering-based investigation of VRLA–AGM batteries in micro-hybrid electric vehicles, PhD thesis, to be published at Universität Ulm.
5. Schaeck · Journal of Power Sources · 2009 · 190 · 17310.1016/j.jpowsour.2008.10.061 ↗
6. Dudenhöffer · ATZ · 2004 · 106 · 42
7. ADAC e.V. (German Automobile Club), ADAC Statistik Batteriepannen 1996 und 2006, March 2009, www.adac.de.
8. T. Handschuh, Untersuchung des Betriebs- und Alterungsverhaltens von Blei-Säure-Akkumulatoren bei für Hybridantriebssystemen typischen Belastungen, PhD thesis, Universität Ulm, 2007.
9. Karden · 2004
10. Sauer · Journal of Power Sources · 2007 · 168 · 2210.1016/j.jpowsour.2006.11.064 ↗
11. Albers · Journal of Power Sources · 2009 · 190 · 16210.1016/j.jpowsour.2008.12.105 ↗
12. Cooper · Journal of Power Sources · 2009 · 188 · 64210.1016/j.jpowsour.2008.11.119 ↗
13. S. Schaeck, T. Karspeck, C. Ott, M. Weckler, A.O. Stoermer, A field operational test on VRLA–AGM batteries in micro-hybrid electric vehicles. Part I. Results based on Kernel Density Estimation, Journal of Power Sources, accepted for publication.
14. S. Schaeck, T. Karspeck, C. Ott, D. Weirather-Koestner, A.O. Stoermer, A field operational test on VRLA–AGM batteries in micro-hybrid electric vehicles. Part II. Results based on multiple regression analysis and tear-down analysis, Journal of Power Sources, (2010) doi:10.1016/j.jpowsour.2010.08.101.10.1016/j.jpowsour.2010.08.101 ↗
15. Pavlov · Journal of Power Sources · 2009 · 191 · 5810.1016/j.jpowsour.2008.11.056 ↗
16. Moseley · Journal of Power Sources · 2006 · 157 · 310.1016/j.jpowsour.2006.02.031 ↗
17. Moseley · Journal of Power Sources · 2009 · 191 · 13410.1016/j.jpowsour.2008.08.084 ↗
18. Shiomi · Journal of Power Sources · 1997 · 64 · 14710.1016/S0378-7753(96)02515-3 ↗
19. Thele · Journal of Power Sources · 2007 · 168 · 3110.1016/j.jpowsour.2006.11.088 ↗
20. Yamaguchi · Journal of Power Sources · 2001 · 93 · 10410.1016/S0378-7753(00)00554-1 ↗
21. Yamaguchi · Journal of Power Sources · 2001 · 102 · 15510.1016/S0378-7753(01)00794-7 ↗
22. Yamaguchi · Journal of Power Sources · 2000 · 85 · 2210.1016/S0378-7753(99)00377-8 ↗
23. Bode · 1977
24. D.U. Sauer, Optimierung des Einsatzes von Blei-Säure-Akkumulatoren in Photovoltaik-Hybrid-Systemen unter spezieller Berücksichtigung der Batteriealterung, PhD thesis, Universität Ulm, 2003.
25. Kappus · Electrochimica Acta · 1983 · 28 · 152910.1016/0013-4686(83)85212-8 ↗
26. M. Thele, A contribution for the modelling of the charge acceptance of lead-acid batteries – using frequency and time domain based concepts, PhD thesis, RWTH Aachen, 2007.10.1016/j.jpowsour.2006.11.088 ↗
27. E. Meissner, Private communication, April 29, 2009, Hannover.
28. H. Döring, Private communication, June 25, 2009, Stuttgart-Weilimdorf.10.1007/978-3-7643-8736-5_2 ↗
29. D. Berndt, Bleiakkumulatoren, VDI-Verlag, Düsseldorf, 1986.
30. Pavlov · Journal of Power Sources · 2010 · 195 · 444410.1016/j.jpowsour.2009.12.132 ↗
31. Pavlov · Journal of Power Sources · 2010 · 195 · 443510.1016/j.jpowsour.2009.11.060 ↗
32. DIN EN 50342-1, Lead-acid starter batteries – general requirements and methods of test, November 2006.
33. O. Bohlen, Impedance based battery monitoring, PhD thesis, RWTH Aachen, 2008.
34. Kurisawa · 1997
35. Hawkins · 1996
36. Toll · 2002
37. A.O. Stoermer, S. Schaeck, E. Hockgeiger, Design verification of VRLA–AGM batteries, Journal of Power Sources, in preparation.