A review of standardising SOFC measurement and quality assurance at FZJ
Source abstract
Abstract
Abstract The need for standardisation/quality assurance (QA) is argued for citing extant problems with consistency, repeatability and reliability of data. A review of the cell testing procedure/QA system used at Forschungszentrum Julich (FZJ) is given including an outline of how the FZJ system was developed. This is put in the context of more extensive QA systems following the outlines of the ISO 9000 series standards. Examples are used to illustrate how and why a number of standard cell test parameters was adopted. It was found that pre-normative research used to define testing parameters led to an improvement in cell performance generally. Therefore, it is recommended that other solid oxide fuel cells (SOFC) labs develop standardisation in testing and QA systems to maintain and improve their measurement processes.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Advancements in Solid Oxide Fuel Cells · Fuel Cells and Related Materials · Thermal and Kinetic Analysis
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (2)
Show source-provided references
1. V.A.C. Haanappel, A. Mai, J. Mertens, Electrode activation of anode-supported solid oxide fuel cells with LSM- or LSCF-type cathodes, in: Proceedings of the 15th International Conference on Solid State Ionics, Baden-Baden, Germany, 17–22 July, Solid State Ionics 177 (2006) 2003–2037.