journal article·2003-03

Small bandwidth measurement of the noise voltage of batteries

D.H.J. Baert, A.A.K. Vervaet

Journal of Power Sources· Volume 114· Issue 2
Publisher page

Abstract

The purpose of this paper is to measure the very small electrochemical noise voltage (about 10 nV) generated in batteries. The new method presented here is able to realize these measurements of the noise signal in an industrial environment. The technique we developed is based on a small part of the frequency noise spectrum between 3 and 30 Hz. As we will show this seems to offer a good compromise for applications in an industrial environment where a relatively high electrical background noise can be expected to exist. In the proposed measurement setup, we have included the possibility to discriminate between different kinds of noise voltages. This selectivity permits to find indications of different noise generating mechanisms in electrochemical systems, e.g. shot- and burst-noise sources. Measurements confirm the practicability of the proposed measurement setup.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Scientific Measurement and Uncertainty Evaluation · Sensor Technology and Measurement Systems · Advanced Electrical Measurement Techniques

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (24)

Show source-provided references
1. A.R. Waters, K.R. Bullock, Monitoring the state-of-health of VRLA batteries through Ohmic measurements, in: Proceedings of the International Telecommunications Energy Conference (INTELEC), Session 29-1, 1997.10.1109/INTLEC.1997.646069 ↗
2. W.H. Edwards, A.I. Harrison, T.M. Wolstenholme, Conductance measurements in relation to battery state-of-charge, in: Proceedings of the INTELEC, Session 18-3, 1997.
3. J.M. Hawkins, Some field experience with battery impedance measurement as a useful maintenance tool, in: Proceedings of the INTELEC, 1994, pp. 263–269.10.1109/INTLEC.1994.396645 ↗
4. D.C. Cox, R. Perez-Kite, Battery state-of-health monitoring, combining conductance technology with other measurement parameters for real-time battery performance analysis, in: Proceedings of the INTELEC, 2000, pp. 342–347.10.1109/INTLEC.2000.884272 ↗
5. W.R. Bennett, Electrical Noise, McGraw-Hill, London, 1960.
6. A. Van Der Ziel, Fluctuation Phenomena in semi-conductors, Butterworths Scientific Publications, London, 1959.
7. Faradaic noise of complex electrochemical reactions10.1016/0013-4686(71)85075-2 ↗
8. Transient voltage changes produced in corroding metals and alloys10.1149/1.2411362 ↗
9. C. Gabrielli, F. Huet, M. Keddam, Noise in electrochemical systems, in: Proceedings of the International Conference on “Noise in Physical Systems and 1/f Noise”, North-Holland, Amsterdam, 1983, pp. 385–388.
10. Dependence of the phase composition of the anodic layer on oxygen evolution and anodic corrosion of lead electrode in lead dioxide potential region10.1016/0013-4686(78)85079-8 ↗
11. Photo electrochemical properties of the lead electrode during anodic oxidation in sulfuric acid solution10.1149/1.2133105 ↗
12. A general mechanical model for |f|α spectral density random noise with special reference to flicker noise 1/|f|10.1109/PROC.1968.6269 ↗
13. D. Berndt, Maintenance-Free Batteries, Reasearch Studies Press Ltd., Taunton, Somerset, England, 1994, p. 311.
14. The lead–acid battery: semiconducting properties and Peukert’s law10.1016/S0013-4686(02)00249-9 ↗
15. Applications of electrical noise10.1109/PROC.1975.9877 ↗
16. Das Rauschen von Elektro-chemischen Stromquellen
17. The measurement of localized corrosion using electrochemical noise10.1016/0010-938X(81)90006-8 ↗
18. The measurement of corrosion using electrochemical 1/f noise10.1016/0010-938X(82)90107-X ↗
19. Electrochemical noise for evaluating susceptibility of lead–acid battery electrodes to intergranular corrosion10.1179/bcj.1998.33.1.29 ↗
20. Voltage noise measurements on sealed lead–acid batteries10.1016/0378-7753(89)80131-4 ↗
21. Continuous corrosion rate measurement by noise resistance calculation10.1109/19.963158 ↗
22. Application of electrochemical noise analysis to the study of batteries: state-of-charge determination and overcharge detection10.1016/S0378-7753(99)00272-4 ↗
23. D. Baert, A. Vervaet, Determination of state-of-health of VRLA batteries by means of noise measurements, in: Proceedings of the International Telecommunications Energy Conference, 2001, pp. 301–312.10.1049/cp:20010614 ↗
24. How to measure noise that is quieter than your opamp, Princeton Applied Research, Application Note 127, 1974.