journal article·2017-06

Introduction of capacity difference analysis (CDA) for analyzing lateral lithium-ion flow to determine the state of covering layer evolution

Meinert Lewerenz, Alexander Warnecke, Dirk Uwe Sauer

Publisher page

Abstract

Abstract In this contribution a simple in-situ method named capacity difference analysis (CDA) is introduced to characterize lateral flow of lithium-ions within the anode. Therefore, simply the difference between two capacity measurements, which are determined at significantly different current rates, are evaluated for each check-up. During aging the initial capacity difference of 2–3% is reducing for all calendaric and cyclic aged cells until they reach a value which is close to zero difference. The initial capacity difference can be explained by lithium-ion flow between active and passive anode, whereby passive represents the excess anode without counter cathode (passive electrode effect). The successive reduction is likely caused by particle disconnection between active and passive anode and/or dry out of electrolyte in the anode overhang. Furthermore some cyclic aged cells reveal an increase after the initial decrease which can be associated to a process of forming a vertical deposition layer on top of the anode facing the separator that is not permeable to lithium-ions applying reasonable discharge currents. The CDA results are validated by laser microscope imaging after disassembling representative cells. The method is applied on a test matrix presented in our previous publication [1].
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Advanced Battery Technologies Research · Advancements in Battery Materials · Electrical and Bioimpedance Tomography

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (10)

Show source-provided references
1. Systematic aging of commercial LiFePO4jGraphite cylindrical cells including a theory explaining rise of capacity during aging10.1016/j.jpowsour.2017.01.133 ↗
2. Uneven film formation across depth of porous graphite electrodes in cycled commercial Li-Ion batteries
3. Non-uniform aging of cycled commercial LiFePO4//graphite cylindrical cells revealed by post-mortem analysis10.1016/j.jpowsour.2014.01.105 ↗
4. Electrochemical characterization and post-mortem analysis of aged LiMn2O4eLi(Ni0.5Mn0.3Co0.2)O2/graphite lithium ion batteries. Part I: cycle aging10.1016/j.jpowsour.2013.11.080 ↗
5. Understanding anomalous behavior in coulombic efficiency measurements on Li-Ion batteries
6. Aging of a commercial graphite/LiFePO4 cell10.1149/1.3614529 ↗
7. Cell degradation in commercial LiFePO4 cells with high-power and high-energy designs10.1016/j.jpowsour.2014.02.052 ↗
8. Postmortem analysis of calendar-aged graphite/LiFePO4 cells10.1016/j.jpowsour.2013.01.147 ↗
9. A dilatometric study of lithium intercalation into powder-type graphite electrodes10.1149/1.2940573 ↗
10. In situ detection of lithium metal plating on graphite in experimental cells10.1016/j.jpowsour.2015.01.046 ↗