Description of gasket failure in a 7 cell PEMFC stack
Source abstract
Abstract
This article presents the data and the description of a fuel cell stack that failed due to gasket degradation. The fuel cell under study is a 7 cell stack. The unexpected change in several variables such as temperature, pressure and voltage indicated the possible failure of the stack. The stack was monitored over a 6 h period in which data was collected and consequently analyzed to conclude that the fuel cell stack failed due to a crossover leak on the anode inlet port located on the cathode side gasket of cell #2. This stack failure analysis revealed a series of indicators that could be used by a supervisional controller in order to initiate a shutdown procedure.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Fuel Cells and Related Materials · Advancements in Solid Oxide Fuel Cells · Advanced Battery Technologies Research
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (3)
Show source-provided references
1. Silicone. http://www.stockwell.com/newstuff/newpdfs/500_solid_silicone/510_cohr_9275_high_perf_clear_silicone.pdf.
2. Barbir · 2005
3. Electro Chem Inc. website: http://www.fuelcell.com/pdfs/FuelCellStack.pdf (accessed May 2006).