journal article·2009-06

Failure modes of valve-regulated lead-acid batteries for electric bicycle applications in deep discharge

Yonglang Guo, Shengqun Tang, Gang Meng, Shijun Yang

Journal of Power Sources· Volume 191· Issue 1
Publisher page

Abstract

Abstract The 36 or 48 V valve-regulated lead-acid (VRLA) battery packs have been widely applied to the power sources of electric bicycles or light electric scooters in China. The failure modes of the 12 V/10 Ah VRLA batteries have been studied by the cycle life test at C2 discharge rate and 100% depth of discharge (DOD). It indicates that the main cause of the battery failure in this cycle duty is the softening and shedding of positive active mass (PAM) rather than individual water loss, recombination efficiency or sulfation, etc. When the electrolyte saturation falls to a certain extent, the high oxygen recombination current leads to the depolarization of the negative plate and the shift of the positive plate to a higher potential. The violent oxygen evolution accelerates the softening of PAM and the end of cycle life.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Advanced Battery Technologies Research · Advancements in Battery Materials · Advanced DC-DC Converters

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (23)

Show source-provided references
1. Moseley · J. Power Sources · 2007 · 174 · 4910.1016/j.jpowsour.2007.06.065 ↗
2. Shen · Energy Conv. Manage. · 2007 · 48 · 43310.1016/j.enconman.2006.06.023 ↗
3. Blanke · J. Power Sources · 2005 · 144 · 41810.1016/j.jpowsour.2004.10.028 ↗
4. Soria · J. Power Sources · 2007 · 168 · 1210.1016/j.jpowsour.2006.11.086 ↗
5. Ke · 2007 · 1370
6. Pei · Proc. Chin. Soc. Electr. Eng. · 2005 · 25 · 164
7. Cooper · J. Power Sources · 2003 · 113 · 20010.1016/S0378-7753(02)00515-3 ↗
8. Wagner · J. Power Sources · 1995 · 53 · 15310.1016/0378-7753(94)01983-3 ↗
9. Nakamura · J. Power Sources · 1996 · 59 · 15310.1016/0378-7753(95)02317-8 ↗
10. Lam · J. Power Sources · 2004 · 133 · 12610.1016/j.jpowsour.2003.11.048 ↗
11. Atlung · J. Power Sources · 1994 · 52 · 20110.1016/0378-7753(94)01963-0 ↗
12. R.H. Newnham, W.G.A. Balding, A.F. Hollenkamp, O.V. Lim, C.G. Phyland, D.A.J. Rand, J.M. Rosalie, D.G. Vella, ALABC Project C/N 1.1, Advancement of valve-regulated lead-acid battery technology for hybrid-electric and electric vehicles, Semi-annual Report 1 July to 31 December 2001, Advanced Lead-Acid Battery Consortium, Research Triangle Park, NC, USA, 2001.
13. Chang · J. Power Sources · 2000 · 91 · 17710.1016/S0378-7753(00)00470-5 ↗
14. Y. Yamaguchi, K. Hirakawa, E. Hojo, Y. Nakayama, INTELEC, 2001, pp. 369–375.10.1049/cp:20010624 ↗
15. Culpin · J. Power Sources · 1991 · 36 · 41510.1016/0378-7753(91)80069-A ↗
16. Dimitrov · J. Power Sources · 2001 · 93 · 23410.1016/S0378-7753(00)00598-X ↗
17. Nelson · J. Power Sources · 2000 · 88 · 4410.1016/S0378-7753(99)00509-1 ↗
18. Fernandez · J. Power Sources · 2006 · 158 · 114910.1016/j.jpowsour.2006.03.025 ↗
19. Kirchev · J. Power Sources · 2006 · 162 · 86410.1016/j.jpowsour.2005.07.008 ↗
20. Bernardi · J. Electrochem. Soc. · 1995 · 142 · 263110.1149/1.2050066 ↗
21. Guo · J. Electrochem. Soc. · 2007 · 154 · A110.1149/1.2364807 ↗
22. Pavlov · J. Electrochem. Soc. · 1972 · 119 · 810.1149/1.2404142 ↗
23. Pavlov · J. Power Sources · 1981 · 7 · 15310.1016/0378-7753(81)80052-3 ↗