Experimental study on the optimal purge duration of a proton exchange membrane fuel cell with a dead-ended anode
Source abstract
Abstract
Abstract When a proton exchange membrane fuel cell (PEMFC) is operated with a dead-ended anode, impurities gradually accumulate within the anode, resulting in a performance drop. An anode purge is thereby ultimately required to remove impurities within the anode. A purge strategy comprises purge interval (valve closed) and purge duration (valve is open). A short purge interval causes frequent and unnecessary activation of the valve, whereas a long purge interval leads to excessive impurity accumulation. A short purge duration causes an incomplete performance recovery, whereas a long purge duration results in low hydrogen utilization. In this study, a series of experimental trials was conducted to simultaneously measure the hydrogen supply rate and power generation of a PEMFC at a frequency of 50 Hz for various operating current density levels and purge durations. The effect of purge duration on the cell's energy efficiency was subsequently analyzed and discussed. The results showed that the optimal purge duration for the PEMFC was approximately 0.2 s. Based on the results of this study, a methodical process for determining optimal purge durations was ultimately proposed for widespread application. Purging approximately one-fourth of anode gas can obtain optimal energy efficiency for a PEMFC with a dead-ended anode.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Fuel Cells and Related Materials · Electrocatalysts for Energy Conversion · Advanced battery technologies research
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (18)
Show source-provided references
1. Larminie · 2003
2. Performance evaluation of a polymer electrolyte fuel cell with a dead-end anode: a computational fluid dynamic study10.1016/j.ijhydene.2011.05.171 ↗
3. Effect of nitrogen crossover on purging strategy in PEM fuel cell systems10.1016/j.apenergy.2013.06.057 ↗
4. Dead-ended anode polymer electrolyte fuel cell stack operation investigated using electrochemical impedance spectroscopy, off-gas analysis and thermal imaging10.1016/j.jpowsour.2013.11.125 ↗
5. A factorial study to investigate the purging effect on the performance of a dead-end anode PEM fuel cell stack10.1002/fuce.201300069 ↗
6. Paradox phenomena of proton exchange membrane fuel cells operating under dead-end anode mode10.1016/j.jpowsour.2014.04.086 ↗
7. A reverse-current decay mechanism for fuel cells10.1149/1.1896466 ↗
8. Polarization study of a PEMFC with four reference electrodes at hydrogen starvation conditions10.1016/j.jpowsour.2008.01.001 ↗
9. Experimental study on enhancing the fuel efficiency of an anodic dead-end mode polymer electrolyte membrane fuel cell by oscillating the hydrogen10.1016/j.ijhydene.2010.08.076 ↗
10. Optimization of purge cycle for dead-ended anode fuel cell operation10.1016/j.ijhydene.2013.02.022 ↗
11. Experimental analysis of a PEM fuel cell performance at variable load with anodic exhaust management optimization10.1016/j.ijhydene.2012.09.147 ↗
12. An investigation into the effect of anode purging on the fuel cell performance10.1016/j.ijhydene.2010.03.079 ↗
13. Optimization study of purge cycle in proton exchange membrane fuel cell system10.1016/j.jpowsour.2012.11.153 ↗
14. Experimental study of hydrogen purge effects on performance and efficiency of an open-cathode Proton Exchange Membrane fuel cell system10.1016/j.jpowsour.2013.09.122 ↗
15. Hu · 2016 · vol 320 · 68
16. System Catalog vol 1, p32, Burkert Fluid Control Systems. http://www.sagakft.hu/Ipari/Burkert/COM_SK1_GB.pdf (Accessed on October 2016).
17. A mathematical model to study the performance of a proton exchange membrane fuel cell in a dead-ended anode mode10.1016/j.apenergy.2014.05.010 ↗
18. Nitrogen front evolution in purged polymer electrolyte membrane fuel cell with dead-ended anode10.1149/1.3425743 ↗