journal article·2006-04

Operational characteristics of a 50W DMFC stack

Daejin Kim, Jaeyoung Lee, Tae-Hoon Lim, In-Hwan Oh, Heung Yong Ha

Journal of Power Sources· Volume 155· Issue 2
Publisher page

Abstract

Abstract The characteristics of a 50 W direct methanol fuel cell (DMFC) stack were investigated under various operating conditions in order to understand the behavior of the stack. The operating variables included the methanol concentration, the flow rate and the flow direction of the reactants (methanol and air) in the stack. The temperature of the stack was autonomously increased in proportion to the magnitude of the electric load, but it decreased with an increase in the flow rates of the reactants. Although the operation of the stack was initiated at room temperature, under a certain condition the internal temperature of the stack was higher than 80 °C. A uniform distribution of the reactants to all the cells was a key factor in determining the performance of the stack. With the supply of 2 M methanol, a maximum power of the stack was found to be 54 W (85 mW cm −2 ) in air and 98 W (154 mW cm −2 ) in oxygen. Further, the system with counter-flow reactants produced a power output that was 20% higher than that of co-flow system. A post-load behavior of the stack was also studied by varying the electric load at various operating conditions.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Fuel Cells and Related Materials · Electrocatalysts for Energy Conversion · Advancements in Solid Oxide Fuel Cells

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (19)

Show source-provided references
1. Scott · J. Electroanal. Chem. · 1999 · 477 · 9710.1016/S0022-0728(99)00359-9 ↗
2. Scott · J. Power Sources · 1999 · 83 · 20410.1016/S0378-7753(99)00303-1 ↗
3. Kim · J. Power Sources · 2004 · 135 · 2910.1016/j.jpowsour.2004.03.058 ↗
4. Blum · J. Power Sources · 2003 · 117 · 2210.1016/S0378-7753(03)00310-0 ↗
5. Dillon · J. Power Sources · 2004 · 127 · 11210.1016/j.jpowsour.2003.09.032 ↗
6. Kyo · Electrochim. Acta · 2004 · 50 · 78110.1016/j.electacta.2004.01.107 ↗
7. Kim · J. Power Sources · 2004 · 130 · 17210.1016/j.jpowsour.2003.12.023 ↗
8. Heinzel · J. Power Sources · 2002 · 105 · 25010.1016/S0378-7753(01)00948-X ↗
9. Jiang · J. Power Sources · 2001 · 93 · 2510.1016/S0378-7753(00)00539-5 ↗
10. Kumar · J. Power Sources · 2004 · 129 · 6210.1016/j.jpowsour.2003.11.011 ↗
11. Jiang · J. Power Sources · 2004 · 126 · 11910.1016/j.jpowsour.2003.08.022 ↗
12. Dohle · J Power Sources · 2002 · 106 · 31310.1016/S0378-7753(01)01064-3 ↗
13. Buttin · J. Appl. Electrochem. · 2001 · 31 · 27510.1023/A:1017526214805 ↗
14. Gogel · J. Power Sources · 2004 · 127 · 17210.1016/j.jpowsour.2003.09.035 ↗
15. Ravikumar · J. Electrochem. Soc. · 1996 · 143 · 260110.1149/1.1837054 ↗
16. Argyropoulos · Electrochim. Acta · 2000 · 45 · 198310.1016/S0013-4686(99)00420-X ↗
17. Performance durability issues in DMFC operation
18. Argyropoulos · J. Appl. Electrochem. · 2001 · 31 · 1310.1023/A:1004133125725 ↗
19. Qi · J. Power Sources · 2002 · 110 · 17710.1016/S0378-7753(02)00268-9 ↗